Coronary arteries at 3.0 T: Contrast-enhanced magnetization-prepared three-dimensional breathhold MR angiography

被引:41
作者
Bi, XM
Li, DB
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
关键词
magnetic resonance imaging; 3; Tesla; coronary artery imaging; fast imaging; contrast media;
D O I
10.1002/jmri.20250
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the efficacy of contrast-enhanced coronary magnetic resonance angiography (MRA) at 3.0 T. Materials and Methods: Nine healthy human volunteers were studied on a 3.0-T whole-body MR system. A three-dimensional. breathhold. magnetization-prepared. segmented, gradient-echo sequence was used, with injection of 20 mL gadopentetate dimeglumine for each three-dimensional slab. Imaging parameters were optimized based on computer simulations. Signal-to-noise ratio (SNR). contrast-to-noise ratio (CNR). depicted coronary artery length. lumen diameter. and imaging sharpness with contrast agent were evaluated. SNR and CNR were compared to the results from a previous 1.5-T study. Results: A 53% increment in SNR and a 305% enhancement in CNR were measured with contrast. Vessel length and sharpness depicted were higher and the lumen diameter was lower (all P values < 0.05) in postcontrast images. Compared to previous results from 1.5-T, the SNR. CNR, and vessel sharpness were enhanced at 3.0 T with higher spatial resolution. Conclusion: Contrast-enhanced, three-dimensional, coronary MRA at 3.0 T is a promising technique for diagnosing coronary artery diseases. Patient studies are necessary to evaluate its clinical utility.
引用
收藏
页码:133 / 139
页数:7
相关论文
共 20 条
[1]  
BOTTOMLEY PA, 1984, MED PHYS, V11, P425, DOI 10.1118/1.595535
[2]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[3]   BASIC PHYSICS OF MR CONTRAST AGENTS AND MAXIMIZATION OF IMAGE-CONTRAST [J].
HENDRICK, RE ;
HAACKE, EM .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (01) :137-148
[4]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233
[5]  
HOFMAN MBM, 1998, P 6 M INT SOC MAGN R, P845
[6]  
Lee T, 2003, P 11 ANN M ISMRM TOR, P131
[7]   Three-dimensional MRI of coronary arteries using an intravascular contrast agent [J].
Li, DB ;
Dolan, RP ;
Walovitch, RC ;
Lauffer, RB .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (06) :1014-1018
[8]   Coronary arteries: Magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography [J].
Li, DB ;
Carr, JC ;
Shea, SM ;
Zheng, J ;
Deshpande, VS ;
Wielopolski, PA ;
Finn, JP .
RADIOLOGY, 2001, 219 (01) :270-277
[9]   Magnetic resonance imaging of the brain with gadopentetate dimeglumine-DTPA: Comparison of T1-weighted spin-echo and 3D gradient-echo sequences [J].
Li, DB ;
Haacke, EM ;
Tarr, RW ;
Venkatesan, R ;
Lin, WL ;
Wielopolski, P .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (03) :415-424
[10]   Contrast-enhanced MR imaging of coronary arteries: Comparison of intra- and extravascular contrast agents in swine [J].
Li, DB ;
Zheng, J ;
Weinmann, HJ .
RADIOLOGY, 2001, 218 (03) :670-678