Correlation of Intraoperative Optical Coherence Tomography of Crystalline Lens Diameter, Thickness, and Volume with Biometry and Age

被引:22
作者
Waring, George Oral [1 ]
Chang, Daniel H. [2 ]
Rocha, Karolinne Maia [3 ]
Gouvea, Larissa [4 ]
Penatti, Raphael [1 ]
机构
[1] Waring Vis Inst, Mt Pleasant, SC USA
[2] Empire Eye & Laser Ctr, Bakersfield, CA USA
[3] Med Univ South Carolina, Storm Eye Inst, Charleston, SC 29425 USA
[4] Univ Toronto, Dept Ophthalmol & Vis Sci, Toronto, ON, Canada
关键词
REFRACTIVE-INDEX DISTRIBUTION; POWER CALCULATION; IN-VIVO; PRECISION BIOMETRY; ANTERIOR SEGMENT; AXIAL LENGTH; ACCOMMODATION; SHAPE; EYE; PARAMETERS;
D O I
10.1016/j.ajo.2020.12.021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To characterize crystalline lens dimensions derived from in vivo spectral-domain optical coherence tomography (SD-OCT) and identify associations among these parameters, ocular biometry, and age. center dot METHODS: In this retrospective study, lens thickness (LT), lens diameter (LD), and lens volume (LV) were measured intraoperatively using SD-OCT in 293 eyes undergoing lens surgery. Correlations among LT, LD, LV, age, axial length (AL), and anterior chamber depth (ACD) were analyzed. Multiple regression analysis was performed to determine whether a combination of biometric data could predict LD and LV. center dot RESULTS: Wide variations were observed in LT (3.65.7 mm), LD (7.5-11.9 mm), and LV (119.9312.4 mm3) of aging eyes. Correlations among the 3 lens dimensions were statistically significant (LV-LT: r = 0.785; P < .001; LV-LD: r = 0.696; P < .001; and LT-LD: r = 0.121; P = .039). With age, the correlation coefficients of LT, LD, and LV were 0.526, 0.326, and 0.573, respectively (P < .001). Although there was significant correlation of AL with LT (r = L0.137; P = .002) and LD (r = 0.268; P < .001), it was not significant with LV (r = 0.084; P = .15). Subgroup analysis revealed that 19.8% of long eyes had LD > 1 standard deviation (SD) above and that 5.2% had LD < 1 SD below the mean LD. center dot CONCLUSIONS: Dimensions of the aging lens vary considerably and are most accurately characterized by direct measurement of LT, LD, and LV, rather than making assumptions based on AL. These findings challenge historically proposed relationships between LD and AL and represent a normative dataset of contemporary geometric features of the aging lens, possibly aiding in surgical decision making and future developments in lenssurgery. (Am J Ophthalmol 2021;225:147-156. (c) 2020 Elsevier Inc. All rights reserved.) <comment>Superscript/Subscript Available</comment
引用
收藏
页码:147 / 156
页数:10
相关论文
共 50 条
[41]   Biometry and spectral domain optical coherence tomography parameters in children with large cupping [J].
Jong Jin Jung ;
Seung-Hee Baek ;
Ungsoo Samuel Kim .
Graefe's Archive for Clinical and Experimental Ophthalmology, 2013, 251 :2213-2217
[42]   Identification and biometry of horizontal extraocular muscle tendons using optical coherence tomography [J].
Salcedo-Villanueva, Guillermo ;
Paciuc-Beja, Miguel ;
Harasawa, Mariana ;
Velez-Montoya, Raul ;
Olson, Jeffrey L. ;
Oliver, Scott C. ;
Mandava, Naresh ;
Quiroz-Mercado, Hugo .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 253 (03) :477-485
[43]   Accommodation-induced variations in retinal thickness measured by spectral domain optical coherence tomography [J].
Fan, Shanhui ;
Sun, Yong ;
Dai, Cuixia ;
Zheng, Haihua ;
Ren, Qiushi ;
Jiao, Shuliang ;
Zhou, Chuanqing .
JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (09)
[44]   Biometry and spectral domain optical coherence tomography parameters in children with large cupping [J].
Jung, Jong Jin ;
Baek, Seung-Hee ;
Kim, Ungsoo Samuel .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (09) :2213-2217
[45]   Comparison between spectral-domain optical coherence tomography-based and partial coherence interferometry-based biometry [J].
Ahn, So Min ;
Kim, Young Ho ;
Yun, Cheolmin ;
Oh, Jaeryung .
SCIENTIFIC REPORTS, 2024, 14 (01)
[46]   Tissue thickness calculation in ocular optical coherence tomography [J].
Alonso-Caneiro, David ;
Read, Scott A. ;
Vincent, Stephen J. ;
Collins, Michael J. ;
Wojtkowski, Maciej .
BIOMEDICAL OPTICS EXPRESS, 2016, 7 (02) :629-645
[47]   Measurement of Oral Epithelial Thickness by Optical Coherence Tomography [J].
Di Stasio, Dario ;
Lauritano, Dorina ;
Iquebal, Hasan ;
Romano, Antonio ;
Gentile, Enrica ;
Lucchese, Alberta .
DIAGNOSTICS, 2019, 9 (03)
[48]   Macular Thickness by Age and Gender in Healthy Eyes Using Spectral Domain Optical Coherence Tomography [J].
Adhi, Mehreen ;
Aziz, Sumbul ;
Muhammad, Kashif ;
Adhi, Mohammad I. .
PLOS ONE, 2012, 7 (05)
[49]   A Multi Comparison of 8 Different Intraocular Lens Biometry Formulae, Including a Machine Learning Thin Lens Formula (MM) and an Inbuilt Anterior Segment Optical Coherence Tomography Ray Tracing Formula [J].
Mcneely, Richard N. ;
Mcginnity, Katherine ;
Stewart, Stephen ;
Pazo, Emmanuel Eric ;
Moutari, Salissou ;
Moore, Jonathan E. .
VISION, 2024, 8 (03)
[50]   Review of intraoperative optical coherence tomography: technology and applications [Invited] [J].
Carrasco-Zevallos, Oscar M. ;
Viehland, Christian ;
Keller, Brenton ;
Draelos, Mark ;
Kuo, Anthony N. ;
Toth, Cynthia A. ;
Izatt, Joseph A. .
BIOMEDICAL OPTICS EXPRESS, 2017, 8 (03) :1607-1637