Correlation of Intraoperative Optical Coherence Tomography of Crystalline Lens Diameter, Thickness, and Volume with Biometry and Age

被引:22
作者
Waring, George Oral [1 ]
Chang, Daniel H. [2 ]
Rocha, Karolinne Maia [3 ]
Gouvea, Larissa [4 ]
Penatti, Raphael [1 ]
机构
[1] Waring Vis Inst, Mt Pleasant, SC USA
[2] Empire Eye & Laser Ctr, Bakersfield, CA USA
[3] Med Univ South Carolina, Storm Eye Inst, Charleston, SC 29425 USA
[4] Univ Toronto, Dept Ophthalmol & Vis Sci, Toronto, ON, Canada
关键词
REFRACTIVE-INDEX DISTRIBUTION; POWER CALCULATION; IN-VIVO; PRECISION BIOMETRY; ANTERIOR SEGMENT; AXIAL LENGTH; ACCOMMODATION; SHAPE; EYE; PARAMETERS;
D O I
10.1016/j.ajo.2020.12.021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To characterize crystalline lens dimensions derived from in vivo spectral-domain optical coherence tomography (SD-OCT) and identify associations among these parameters, ocular biometry, and age. center dot METHODS: In this retrospective study, lens thickness (LT), lens diameter (LD), and lens volume (LV) were measured intraoperatively using SD-OCT in 293 eyes undergoing lens surgery. Correlations among LT, LD, LV, age, axial length (AL), and anterior chamber depth (ACD) were analyzed. Multiple regression analysis was performed to determine whether a combination of biometric data could predict LD and LV. center dot RESULTS: Wide variations were observed in LT (3.65.7 mm), LD (7.5-11.9 mm), and LV (119.9312.4 mm3) of aging eyes. Correlations among the 3 lens dimensions were statistically significant (LV-LT: r = 0.785; P < .001; LV-LD: r = 0.696; P < .001; and LT-LD: r = 0.121; P = .039). With age, the correlation coefficients of LT, LD, and LV were 0.526, 0.326, and 0.573, respectively (P < .001). Although there was significant correlation of AL with LT (r = L0.137; P = .002) and LD (r = 0.268; P < .001), it was not significant with LV (r = 0.084; P = .15). Subgroup analysis revealed that 19.8% of long eyes had LD > 1 standard deviation (SD) above and that 5.2% had LD < 1 SD below the mean LD. center dot CONCLUSIONS: Dimensions of the aging lens vary considerably and are most accurately characterized by direct measurement of LT, LD, and LV, rather than making assumptions based on AL. These findings challenge historically proposed relationships between LD and AL and represent a normative dataset of contemporary geometric features of the aging lens, possibly aiding in surgical decision making and future developments in lenssurgery. (Am J Ophthalmol 2021;225:147-156. (c) 2020 Elsevier Inc. All rights reserved.) <comment>Superscript/Subscript Available</comment
引用
收藏
页码:147 / 156
页数:10
相关论文
共 50 条
[31]   "In Situ" Corneal and Contact Lens Thickness Changes with High-Resolution Optical Coherence Tomography [J].
Gonzalez-Meijome, Jose M. ;
Cervino, Alejandro ;
Peixoto-de-Matos, Sofia C. ;
Madrid-Costa, David ;
Jorge, Jorge ;
Ferrer-Blasco, Teresa .
CORNEA, 2012, 31 (06) :633-638
[32]   Retinal thickness measurements with optical coherence biometry and optical coherence tomography; [Messung der Netzhautdicke mittels Optischer Kohärenzbiometrie und Optischer Kohärenztomografie] [J].
Resch M.D. ;
Takáts J. ;
Csákány B. ;
Maneschg O. ;
Marsovszky L. ;
Szabó A. ;
Papp A. ;
Németh J. .
Spektrum der Augenheilkunde, 2014, 28 (3) :121-125
[33]   Accuracy of the reconstruction of the crystalline lens gradient index with optimization methods from Ray Tracing and Optical Coherence Tomography data [J].
de Castro, Alberto ;
Barbero, Sergio ;
Ortiz, Sergio ;
Marcos, Susana .
OPTICS EXPRESS, 2011, 19 (20) :19265-19279
[34]   A simple description of age-related changes in crystalline lens thickness [J].
Carmen Garcia-Domene, Mari ;
Amparo Diez-Ajenjo, Ma ;
Gracia, Victor ;
Felipe, Adelina ;
Artigas, Jose M. .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2011, 21 (05) :597-603
[35]   Relations Among Corneal Curvature, Thickness, and Volume in Keratoconus as Evaluated by Anterior Segment-Optical Coherence Tomography [J].
Morishige, Naoyuki ;
Magome, Kazuyoshi ;
Ueno, Akifumi ;
Matsui, Taka-Aki ;
Nishida, Teruo .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (12) :3794-3802
[36]   Advances in intraoperative optical coherence tomography for surgical guidance [J].
El-Haddad, Mohamed T. ;
Tao, Yuankai K. .
CURRENT OPINION IN BIOMEDICAL ENGINEERING, 2017, 3 :37-48
[37]   Normative Data of Ocular Biometry, Optical Coherence Tomography, and Electrophysiology Conducted for Cynomolgus Macaque Monkeys [J].
Choi, Kwang-Eon ;
Vu Thi Que Anh ;
Yun, Cheolmin ;
Kim, Young-Jin ;
Jung, Hachul ;
Eom, Heejong ;
Shin, Dongkwan ;
Kim, Seong-Woo .
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (13)
[38]   Automatic intraocular lens segmentation and detection in optical coherence tomography imagese [J].
Gillner, Melanie ;
Eppig, Timo ;
Langenbucher, Achim .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2014, 24 (02) :104-111
[39]   Measurement of gradient refractive index profile of crystalline lens of fisheye in vivo using optical coherence tomography [J].
Verma, Y. ;
Rao, K. D. ;
Suresh, M. K. ;
Patel, H. S. ;
Gupta, P. K. .
APPLIED PHYSICS B-LASERS AND OPTICS, 2007, 87 (04) :607-610
[40]   The Non-uniform Distribution of Horizontal and Vertical Crystalline Lens Rise Using Optical Coherence Tomography [J].
Fan, Limin ;
Chang, Zheng ;
Xu, Yangtao ;
Yin, Xinkai ;
Wang, Zheng .
JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (05) :354-+