Correlation of Intraoperative Optical Coherence Tomography of Crystalline Lens Diameter, Thickness, and Volume with Biometry and Age

被引:21
|
作者
Waring, George Oral [1 ]
Chang, Daniel H. [2 ]
Rocha, Karolinne Maia [3 ]
Gouvea, Larissa [4 ]
Penatti, Raphael [1 ]
机构
[1] Waring Vis Inst, Mt Pleasant, SC USA
[2] Empire Eye & Laser Ctr, Bakersfield, CA USA
[3] Med Univ South Carolina, Storm Eye Inst, Charleston, SC 29425 USA
[4] Univ Toronto, Dept Ophthalmol & Vis Sci, Toronto, ON, Canada
关键词
REFRACTIVE-INDEX DISTRIBUTION; POWER CALCULATION; IN-VIVO; PRECISION BIOMETRY; ANTERIOR SEGMENT; AXIAL LENGTH; ACCOMMODATION; SHAPE; EYE; PARAMETERS;
D O I
10.1016/j.ajo.2020.12.021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
center dot PURPOSE: To characterize crystalline lens dimensions derived from in vivo spectral-domain optical coherence tomography (SD-OCT) and identify associations among these parameters, ocular biometry, and age. center dot METHODS: In this retrospective study, lens thickness (LT), lens diameter (LD), and lens volume (LV) were measured intraoperatively using SD-OCT in 293 eyes undergoing lens surgery. Correlations among LT, LD, LV, age, axial length (AL), and anterior chamber depth (ACD) were analyzed. Multiple regression analysis was performed to determine whether a combination of biometric data could predict LD and LV. center dot RESULTS: Wide variations were observed in LT (3.65.7 mm), LD (7.5-11.9 mm), and LV (119.9312.4 mm3) of aging eyes. Correlations among the 3 lens dimensions were statistically significant (LV-LT: r = 0.785; P < .001; LV-LD: r = 0.696; P < .001; and LT-LD: r = 0.121; P = .039). With age, the correlation coefficients of LT, LD, and LV were 0.526, 0.326, and 0.573, respectively (P < .001). Although there was significant correlation of AL with LT (r = L0.137; P = .002) and LD (r = 0.268; P < .001), it was not significant with LV (r = 0.084; P = .15). Subgroup analysis revealed that 19.8% of long eyes had LD > 1 standard deviation (SD) above and that 5.2% had LD < 1 SD below the mean LD. center dot CONCLUSIONS: Dimensions of the aging lens vary considerably and are most accurately characterized by direct measurement of LT, LD, and LV, rather than making assumptions based on AL. These findings challenge historically proposed relationships between LD and AL and represent a normative dataset of contemporary geometric features of the aging lens, possibly aiding in surgical decision making and future developments in lenssurgery. (Am J Ophthalmol 2021;225:147-156. (c) 2020 Elsevier Inc. All rights reserved.) <comment>Superscript/Subscript Available</comment
引用
收藏
页码:147 / 156
页数:10
相关论文
共 50 条
  • [1] Optical Coherence Tomography Based Estimates of Crystalline Lens Volume, Equatorial Diameter, and Plane Position
    Martinez-Enriquez, Eduardo
    Sun, Mengchan
    Velasco-Ocana, Miriam
    Birkenfeld, Judith
    Perez-Merino, Pablo
    Marcos, Susana
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (09) : OCT600 - OCT610
  • [2] Lens thickness with age and accommodation by optical coherence tomography
    Richdale, Kathryn
    Bullimore, Mark A.
    Zadnik, Karla
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2008, 28 (05) : 441 - 447
  • [3] Retinal thickness measurements with optical coherence biometry and optical coherence tomography
    Resch, Miklos D.
    Takats, Judit
    Csakany, Bela
    Maneschg, Otto
    Marsovszky, Laszlo
    Szabo, Antal
    Papp, Andras
    Nemeth, Janos
    SPEKTRUM DER AUGENHEILKUNDE, 2014, 28 (03) : 121 - 125
  • [4] Association between axial length and in vivo human crystalline lens biometry during accommodation: a swept-source optical coherence tomography study
    Shoji, Takuhei
    Kato, Naoko
    Ishikawa, Sho
    Ibuki, Hisashi
    Yamada, Norihiro
    Kimura, Itaru
    Shinoda, Kei
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2020, 64 (01) : 93 - 101
  • [5] Validation of Optical Coherence Tomography-Based Crystalline Lens Thickness Measurements in Children
    Lehman, Bret M.
    Berntsen, David A.
    Bailey, Melissa D.
    Zadnik, Karla
    OPTOMETRY AND VISION SCIENCE, 2009, 86 (03) : 181 - 187
  • [6] Increased crystalline lens coverage in optical coherence tomography with oblique scanning and volume stitching
    Chen, Yiwei
    Manzanera, Silvestre
    Mompean, Juan
    Ruminski, Daniel
    Grulkowski, Ireneusz
    Artal, Pablo
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (03) : 1529 - 1542
  • [7] Semiautomated analysis of optical coherence tomography crystalline lens images under simulated accommodation
    Kim, Eon
    Ehrmann, Klaus
    Uhlhorn, Stephen
    Borja, David
    Arrieta-Quintero, Esdras
    Parel, Jean-Marie
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (05)
  • [8] Establishment of Personalized Finite Element Model of Crystalline Lens Based on Sweep-Source Optical Coherence Tomography
    Liu, Guangheng
    Li, Ang
    Liu, Jian
    Zhao, Yuqian
    Zhu, Keliang
    Li, Zhen
    Lin, Yang
    Yan, Shixin
    Lv, Hongyu
    Wang, Shuanglian
    Yu, Yao
    Wang, Yi
    Luan, Jingmin
    Ma, Zhenhe
    PHOTONICS, 2022, 9 (11)
  • [9] In vivo measurement of the average refractive index of the human crystalline lens using optical coherence tomography
    de Freitas, Carolina
    Ruggeri, Marco
    Manns, Fabrice
    Ho, Arthur
    Parel, Jean-Marie
    OPTICS LETTERS, 2013, 38 (02) : 85 - 87
  • [10] Automatic Biometry of the Anterior Segment During Accommodation Imaged by Optical Coherence Tomography
    Zhu, Dexi
    Shao, Yilei
    Leng, Lin
    Xu, Zhe
    Wang, Jianhua
    Lu, Fan
    Shen, Meixiao
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2014, 40 (04): : 232 - 238