Digital image based simple scanometric device for the express detection of aqueous contamination of Hg2+

被引:7
作者
Poornima, V. [1 ]
Alexandar, V. [2 ]
Iswariya, S. [1 ]
Parameshwari, A. Dhivya [3 ]
Muthukumar, R. [4 ]
Uma, T. S. [1 ]
机构
[1] CSIR, CLRI, Biol Mat Lab, Madras 600020, Tamil Nadu, India
[2] CARE, Fac Allied Hlth Sci, Madras, Tamil Nadu, India
[3] Sri Ramakrishna Engn Coll, Dept Nanosci & Nanotechnol, Coimbatore, Tamil Nadu, India
[4] SRM Univ, Sch Bioengn, Dept Biotechnol, Kattankulatur, India
关键词
Colorimetric detection; Digital image scanometry; Gold nanoparticle; Protein corona; Bio-functionalized; Mercury contamination; RGB; Color ratio; Pixel intensity; GOLD NANOPARTICLES; COLORIMETRIC DETECTION; QUANTUM DOTS; MERCURY(II); ASSAY; LEAD; ANTIAGGREGATION; STRATEGY; SENSOR; WATER;
D O I
10.1016/j.snb.2018.07.120
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Detection of mercury ion (Hg2+) contamination is of utmost importance as it poses a major ecological problem, and its increased accumulation would affect the flora and fauna. Herein we report an instrument free colorimetric sensing of Hg2+ using bio-functionalized gold nanoparticle (A-GNP). Digital image scanner (DIS) is used in the detection of Hg2+ based on the change in RGB AVG (Red, Blue and Green) intensities of A-GNP solution upon the addition of different concentrations of Hg2+. The limit of detection (LOD) for naked eye detection was 5 nM, while the DIS system had a LOD of 3 ppt and the limit of quantification (LOQ) 3.68 aM. This concentration is very much lower as compared to the permissible limits prescribed by the USA-EPA. RGB changes for lower concentrations of Hg2+ undifferentiated to naked eye was monitored using our digital image scanometer (DIS) and were cross verified using UV-vis spectroscopy. The DIS system was employed for testing tap water as well as ground water and the results produced were satisfactory in nature. The proposed DIS system can be used for on spot detection of water samples and the analysis does not involve tedious procedures such as sample collection, processing and storage prior to detection using traditional methods. The DIS system is both sensitive and selective and is specific to the detection of mercury. Thus, our study provides a highly sensitive and cost effective system for mercury detection in rural areas where the access to sophisticated instruments is negligible.
引用
收藏
页码:472 / 480
页数:9
相关论文
共 50 条
  • [21] Dissecting the effect of anions on Hg2+ detection using a FRET based DNA probe
    Kiy, Mehmet Murat
    Zaki, Ahmed
    Menhaj, Arsalsan Beg
    Samadi, Azadeh
    Liu, Juewen
    ANALYST, 2012, 137 (15) : 3535 - 3540
  • [22] Ultrasensitive colorimetric detection of Hg2+ based on glutathione-modified Au nanoflowers
    Bai, Dehong
    Xue, Ziyu
    Guo, Peiqing
    Qiu, Mingzhu
    Lei, Xuefang
    Li, Yujin
    Ma, Chengjie
    Zhang, Dongxia
    Zhou, Xibin
    MICROCHEMICAL JOURNAL, 2022, 181
  • [23] A turn-on fluorescent probe for Hg2+ detection by using gold nanoparticle-based hybrid microgels
    Tang, Yecang
    Ding, Yi
    Wu, Ting
    Lv, Liying
    Yan, Zhicheng
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 228 : 767 - 773
  • [24] A highly sensitivity fluorescent probe based on rhodamine for naked-eye detection of Hg2+ in aqueous solution
    Meng, Xianjiao
    Li, Zhichun
    Ma, Wenbing
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2023, 103 (17) : 5558 - 5568
  • [25] Electrochemical DNA sensor based on T-Hg-T pairs and exonuclease III for sensitive detection of Hg2+
    Wang, Xuan
    Xu, Chenfei
    Wang, Yuxian
    Li, Wei
    Chen, Zhengbo
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 343
  • [26] Electrochemical DNA probe for Hg2+ detection based on a triple-helix DNA and Multistage Signal Amplification Strategy
    Wang, Huan
    Zhang, Yihe
    Ma, Hongmin
    Ren, Xiang
    Wang, Yaoguang
    Zhang, Yong
    Wei, Qin
    BIOSENSORS & BIOELECTRONICS, 2016, 86 : 907 - 912
  • [27] An aqueous fluorescent probe for Hg2+ detection with high selectivity and sensitivity
    Fang, Qian
    Liu, Qian
    Song, Xiangzhi
    Kang, Jian
    LUMINESCENCE, 2015, 30 (08) : 1280 - 1284
  • [28] Coumarin-based Hg2+ fluorescent probe: Fluorescence turn-on detection for Hg2+ bioimaging in living cells and zebrafish
    Chen, Chong-Guang
    Vijay, Natarajan
    Thirumalaivasan, Natesan
    Velmathi, Sivan
    Wu, Shu-Pao
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2019, 219 : 135 - 140
  • [29] A simple colorimetric sensor based on anti-aggregation of gold nanoparticles for Hg2+ detection
    Ding, Nan
    Zhao, Hong
    Peng, Wenbo
    He, Yujian
    Zhou, Ying
    Yuan, Longfei
    Zhang, Yuanxun
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2012, 395 : 161 - 167
  • [30] A Localized Surface Plasmon Resonance (LSPR)-based, simple, receptor-free and regeneratable Hg2+ detection system
    Park, Jin-Ho
    Byun, Ju-Young
    Yim, Sang-Youp
    Kim, Min-Gon
    JOURNAL OF HAZARDOUS MATERIALS, 2016, 307 : 137 - 144