CT angiography prior to TAVI procedure using third-generation scanner with wide volume coverage: feasibility, renal safety and diagnostic accuracy for coronary tree

被引:45
作者
Annoni, Andrea D. [1 ]
Andreini, Daniele [1 ]
Pontone, Gianluca [1 ]
Mancini, Maria Elisabetta [1 ]
Formenti, Alberto [1 ]
Mushtaq, Saima [1 ]
Baggiano, Andrea
Conte, Edoardo [1 ]
Guglielmo, Marco [1 ]
Muscogiuri, Giuseppe [1 ]
Muratori, Manuela [1 ]
Fusini, Laura [1 ]
Trabattoni, Daniela [1 ]
Teruzzi, Giovanni [1 ]
Santos, Ana I. Coutinho [2 ]
Agrifoglio, Marco [3 ,4 ]
Pepi, Mauro [1 ]
机构
[1] IRCCS, Dept Cardiovasc Imaging, Ctr Cardiol Monzino, Milan, Italy
[2] Ctr Hosp Lisboa Ocidental, EPE, Imaging Dept, Lisbon, Portugal
[3] Univ Milan, Dept Clin Sci & Community Community Hlth, Milan, Italy
[4] IRCCS, Cardiac Surg Dept, Ctr Cardiol Monzino, Milan, Italy
关键词
AORTIC-VALVE IMPLANTATION; MULTIDETECTOR COMPUTED-TOMOGRAPHY; ARTERY-DISEASE; IMAGE QUALITY; REPLACEMENT; STENOSIS; SURGERY;
D O I
10.1259/bjr.20180196
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate feasibility, image quality and accuracy of a reduced contrast volume protocol for pre-procedural CT imaging in transcatheter aortic valve implantation (TAVI) using a third generation wide array CT scanner. Methods: 115 consecutive patients (51F, mean age 82.5 +/- 6.2 y, mean BMI 26.7 +/- 3.6) referred for TAVI were examined with wide-array CT scanner with a combined scan protocol and a total amount of 50 ml contrast agent. A 4-point visual scale (4-1) was used to assess image quality. Contrast attenuation values (HU) and contrast-to-noise ratio (CNR) were measured at the level of the aortic root, ascending/descending aorta, subrenal aorta and at the level of right and left common femoral arteries. Coronary tree was assessed and compared with invasive coronary angiography (ICA). Aortic annulus measurements were compared with final procedural results. Patients creatinine was monitored at the baseline and 72 h after procedure. Results: Median quality score value was >3. Mean CNR at the level of the aortic root, ascending/descending aorta, subrenal aorta and at the level of right and left common femoral arteries were 14.8 +/- 2.3, 15.7 +/- 1.7, 14.9 +/- 3.1, 15.8 +/- 4.7, 20.3 +/- 9.9, 20.8 +/- 6.9 respectively. Only 1 patient had moderate paravalvular regurgitation. In comparison with ICA for coronary assessment CTA showed in a segment based analysis sensitivity, specificity, negative predictive value, positive predictive value and accuracy of 97, 85, 99,62 and 88% respectively. Mean creatinine before CT and 72 h after procedure were 1.21 +/- 0.52 and1.22 +/- 0.49 mg dl(-1). Mean DLP was 442.4 +/- 21.2 mGy/cm. Conclusion: CT with low contrast volume is feasible and clinically useful, allowing precise pre-procedural TAVI planning with accurate assessment of coronary tree. Advances in knowledge: third generation CT scanner with whole heart coverage allows examinations for assessment of aorta and coronary arteries in TAVI planning using low dose of contrast medium maintaining good quality and high diagnostic accuracy.
引用
收藏
页数:11
相关论文
共 33 条
  • [1] Abbara Suhny, 2009, J Cardiovasc Comput Tomogr, V3, P190, DOI 10.1016/j.jcct.2009.03.004
  • [2] SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR)
    Achenbach, Stephan
    Delgado, Victoria
    Hausleiter, Joerg
    Schoenhagen, Paul
    Min, James K.
    Leipsic, Jonathon A.
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) : 366 - 380
  • [3] Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
    Adams, David H.
    Popma, Jeffrey J.
    Reardon, Michael J.
    Yakubov, Steven J.
    Coselli, Joseph S.
    Deeb, G. Michael
    Gleason, Thomas G.
    Buchbinder, Maurice
    Hermiller, James, Jr.
    Kleiman, Neal S.
    Chetcuti, Stan
    Heiser, John
    Merhi, William
    Zorn, George
    Tadros, Peter
    Robinson, Newell
    Petrossian, George
    Hughes, G. Chad
    Harrison, J. Kevin
    Conte, John
    Maini, Brijeshwar
    Mumtaz, Mubashir
    Chenoweth, Sharla
    Oh, Jae K.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19) : 1790 - 1798
  • [4] Image quality and radiation dose of coronary CT angiography performed with whole-heart coverage CT scanner with intra-cycle motion correction algorithm in patients with atrial fibrillation
    Andreini, Daniele
    Pontone, Gianluca
    Mushtaq, Saima
    Mancini, Maria Elisabetta
    Conte, Edoardo
    Guglielmo, Marco
    Volpato, Valentina
    Annoni, Andrea
    Baggiano, Andrea
    Formenti, Alberto
    Ditali, Valentina
    Perchinunno, Marco
    Fiorentini, Cesare
    Bartorelli, Antonio L.
    Pepi, Mauro
    [J]. EUROPEAN RADIOLOGY, 2018, 28 (04) : 1383 - 1392
  • [5] Diagnostic accuracy of multidetector computed tomography coronary angiography in 325 consecutive patients referred for transcatheter aortic valve replacement
    Andreini, Daniele
    Pontone, Gianluca
    Mushtaq, Saima
    Bartorelli, Antonio L.
    Ballerini, Giovanni
    Bertella, Erika
    Segurini, Chiara
    Conte, Edoardo
    Annoni, Andrea
    Baggiano, Andrea
    Formenti, Alberto
    Fusini, Laura
    Tamborini, Gloria
    Alamanni, Francesco
    Fiorentini, Cesare
    Pepi, Mauro
    [J]. AMERICAN HEART JOURNAL, 2014, 168 (03) : 332 - 339
  • [6] Austen W G, 1975, Circulation, V51, P5
  • [7] High-risk situations and procedures
    Becker, Christoph R.
    Davidson, Charles
    Lameire, Norbert
    McCullough, Peter A.
    Stacul, Fulvio
    Tumlin, James
    Adam, Andy
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (6A) : 37K - 41K
  • [8] Contrast volume reduction using third generation dual source computed tomography for the evaluation of patients prior to transcatheter aortic valve implantation
    Bittner, Daniel O.
    Arnold, Martin
    Klinghammer, Lutz
    Schuhbaeck, Annika
    Hell, Michaela M.
    Muschiol, Gerd
    Gauss, Soeren
    Lell, Michael
    Uder, Michael
    Hoffmann, Udo
    Achenbach, Stephan
    Marwan, Mohamed
    [J]. EUROPEAN RADIOLOGY, 2016, 26 (12) : 4497 - 4504
  • [9] A Practical Guide to Multimodality Imaging of Transcatheter Aortic Valve Replacement
    Bloomfield, Gerald S.
    Gillam, Linda D.
    Hahn, Rebecca T.
    Kapadia, Samir
    Leipsic, Jonathon
    Lerakis, Stamatios
    Tuzcu, Murat
    Douglas, Pamela S.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2012, 5 (04) : 441 - 455
  • [10] Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography
    Cademartiri, Filippo
    Maffei, Erica
    Palumbo, Anselmo Alessandro
    Malago, Roberto
    La Grutta, Ludovico
    Meiijboom, W. Bob
    Aldrovandi, Annachiara
    Fusaro, Michele
    Vignali, Luigi
    Menozzi, Alberto
    Brambilla, Valerio
    Coruzzi, Paolo
    Midiri, Massimo
    Kirchin, Miles A.
    Mollet, Nico R. A.
    Krestin, Gabriel P.
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (03) : 576 - 583