Development of cholesterol biosensor based on immobilized cholesterol esterase and cholesterol oxidase on oxygen electrode for the determination of total cholesterol in food samples

被引:58
作者
Basu, Anjan Kumar [1 ]
Chattopadhyay, Parimal [1 ]
Roychoudhuri, Utpal [1 ]
Chakraborty, Runu [1 ]
机构
[1] Jadavpur Univ, Dept Food Technol & Biochem Engn, Kolkata 700032, W Bengal, India
关键词
ChEt; cholesterol biosensor; ChCX; food sample analysis; stability;
D O I
10.1016/j.bioelechem.2006.05.006
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The development of a cholesterol biosensor by co-immobilization of cholesterol esterase (ChEt) and cholesterol oxidase (ChOX) on oxygen electrode is described. The electrode consists of gold cathode and Ag/AgCl anode. The enzymes were immobilized by cross-linking with glutaraldehyde and Bovine Serum Albumin (BSA). The immobilized enzymatic membrane was attached to the tip of the electrode by a push cap system. The optimum pH and temperature of the sensor was determined, these are 6 and 25 degrees C respectively. The developed sensor was calibrated from 1-75 mg/dl of cholesterol palmiate and found linear in the range of 2-50 mg/dL. The calibration curve was drawn with V-i (ppm/min)(initial velocity) vs different concentrations of cholesterol palmiate (mg/dL). The application of the sensor to determine the total cholesterol in different real food samples such as egg, meat was investigated. The immobilized enzymatic layer can be reused over 30 times and the stability of the enzymatic layer was studied up to 9 weeks. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:375 / 379
页数:5
相关论文
共 28 条
[1]   Gas-liquid chromatographic determination of total and free cholesterol in egg pastas [J].
Agullo, E ;
Gelos, BS .
FOOD RESEARCH INTERNATIONAL, 1996, 29 (01) :77-80
[2]   REDUCING THE INFLUENCE OF SAMPLE OXYGEN IN BIOSENSOR DESIGN [J].
ALBANTOV, AF .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (08) :575-585
[3]  
ALLAIN CC, 1974, CLIN CHEM, V20, P470
[4]  
Basu Anjan Kumar, 2005, Indian Journal of Experimental Biology, V43, P646
[5]   SERUM-CHOLESTEROL DETERMINATION BY GAS-LIQUID CHROMATOGRAPHY [J].
BLOMHOFF, JP .
CLINICA CHIMICA ACTA, 1973, 43 (02) :257-265
[6]   Amperometric determination of cholesterol in serum using a biosensor of cholesterol oxidase contained within a polypyrrole-hydrogel membrane [J].
Brahim, S ;
Narinesingh, D ;
Guiseppi-Elie, A .
ANALYTICA CHIMICA ACTA, 2001, 448 (1-2) :27-36
[7]  
DAS D, 2000, BIOCHEMISTRY-US, P73
[8]   DETERMINATION OF TOTAL CHOLESTEROL IN SERUM BY FLOW-INJECTION ANALYSIS WITH IMMOBILIZED ENZYMES [J].
FERNANDEZROMERO, JM ;
DECASTRO, MDL ;
VALCARCEL, M .
CLINICA CHIMICA ACTA, 1987, 167 (01) :97-104
[9]  
FOLCH J, 1957, J BIOL CHEM, V226, P497
[10]  
Foster R, 2000, ELECTROANAL, V12, P716, DOI 10.1002/1521-4109(200005)12:9<716::AID-ELAN716>3.0.CO