An underfrequency load shedding scheme for high dependability and security tolerant to induction motors dynamics

被引:6
作者
Maresch, K. [1 ]
Marchesan, G. [2 ]
Cardoso Junior, G. [3 ]
Borges, Adriano [3 ]
机构
[1] Univ Fed Santa Maria UFSM, Programa Posgrad Engn Eletr PPGEE, Ctr Excelencia Energia & Sistemas Potencia CEESP, Lab Anal & Protecao Sistemas Eletr LAPES, Santa Maria, RS, Brazil
[2] Univ Fed Santa Maria, PPGEE, Dept Eletromecan & Sistemas Potencia DESP, CEESP,LAPES, Santa Maria, RS, Brazil
[3] Univ Fed Santa Maria, DESP, CEESP, LAPES, Santa Maria, RS, Brazil
关键词
Under-frequency load shedding; Induction motor dynamics; Discriminant functions analysis;
D O I
10.1016/j.epsr.2021.107217
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The load shedding scheme is a last resort to prevent power system collapse when the available generation is less than the load demand. The traditional load shedding schemes monitors the frequency and voltage by underfrequency and undervoltage relays and provides load cutoff until the frequency returns to a stable point of operation. The reduction of rotating inertia demands faster load shedding to meet the stability requirements. In some electrical power systems in Brazil, it was found that, in the event of opening a transmission line upstream of the load shedding substation, some under frequency relay may operate improperly. This paper proposes a new method to avoid the unwanted operation of load shedding schemes when the utility substation (source) is out of service. The proposed method monitors negative sequence voltage, frequency and its rate of change, enabling faster load shedding (high dependability) without unwanted (high security) operation when compared with traditional methods. Events were classified by linear discriminant analysis and tested in the IEEE 9 bus test system. The tests consisted of several disturbances such as loss of generation and line outages at different levels of feeder loading, reactive compensation and distributed generation. The proposed method reached a 100% rate of correct classification.
引用
收藏
页数:8
相关论文
共 22 条
[11]   Adaptive Under-Frequency Load-Shedding Considering Load Dynamics and Post Corrective Actions to Prevent Voltage Instability [J].
Horri, Ramin ;
Roudsari, H. Mahdinia .
ELECTRIC POWER SYSTEMS RESEARCH, 2020, 185
[12]  
IEEE, 2007, C37 IEEE, P117
[13]   Long-Term Impact Evaluation of Advanced Under Frequency Load Shedding Schemes on Distribution Systems With DG Islanded Operation [J].
Issicaba, Diego ;
da Rosa, Mauro Augusto ;
Resende, Fernanda Oliveira ;
Santos, Bruno ;
Pecas Lopes, Joao Abel .
IEEE TRANSACTIONS ON SMART GRID, 2019, 10 (01) :238-247
[14]   An Underfrequency Load Shedding Scheme for Hybrid and Multiarea Power Systems [J].
Ketabi, Abbas ;
Fini, Masoud Hajiakbari .
IEEE TRANSACTIONS ON SMART GRID, 2015, 6 (01) :82-91
[15]  
Ladhani SS, 2004, 2004 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1 AND 2, P1597
[16]   Continuous Under-Frequency Load Shedding Scheme for Power System Adaptive Frequency Control [J].
Li, Changgang ;
Wu, Yue ;
Sun, Yanli ;
Zhang, Hengxu ;
Liu, Yutian ;
Liu, Yilu ;
Terzija, Vladimir .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2020, 35 (02) :950-961
[17]   A Sensitivity-Based Method for Under-Frequency Load-Shedding [J].
Reddy, C. P. ;
Chakrabarti, S. ;
Srivastava, S. C. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2014, 29 (02) :984-985
[18]   A Synchrophasor Assisted Frequency and Voltage Stability Based Load Shedding Scheme for Self-Healing of Power System [J].
Seethalekshmi, K. ;
Singh, S. N. ;
Srivastava, S. C. .
IEEE TRANSACTIONS ON SMART GRID, 2011, 2 (02) :221-230
[19]   An Analytical Adaptive Load Shedding Scheme Against Severe Combinational Disturbances [J].
Shekari, Tohid ;
Aminifar, Farrokh ;
Sanaye-Pasand, Majid .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (05) :4135-4143
[20]   An MILP formulation for controlled islanding coordinated with under frequeny load shedding plan [J].
Teymouri, Farhad ;
Amraee, Turaj .
ELECTRIC POWER SYSTEMS RESEARCH, 2019, 171 :116-126