The effect of pH, fluoride and tribocorrosion on the surface properties of dental archwires

被引:36
作者
Mocnik, Petra [1 ]
Kosec, Tadeja [1 ]
Kovac, Janez [2 ]
Bizjak, Milan [3 ]
机构
[1] Slovenian Natl Bldg & Civil Engn Inst, Dimiceva 12, SI-1000 Ljubljana, Slovenia
[2] Jozef Stefan Inst, Jamova 39, SI-1000 Ljubljana, Slovenia
[3] Univ Ljubljana, Fac Nat Sci & Engn, Askerceva 12, SI-1000 Ljubljana, Slovenia
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2017年 / 78卷
关键词
Dental wires; NiTi; Stainless steel; Tribocorrosion; Passive film; Simulated saliva; Ni release; SHAPE-MEMORY ALLOYS; CORROSION-RESISTANCE; ORTHODONTIC WIRES; ARTIFICIAL SALIVA; STAINLESS-STEEL; NITI ALLOY; ELECTROCHEMICAL-BEHAVIOR; TITANIUM; WEAR;
D O I
10.1016/j.msec.2017.04.050
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Nickel-titanium and stainless steel are the most commonly used alloys for orthodontic treatments. Even though both are known to be resistant to corrosion, there are circumstances that can lead to undesired situations, like localized types of corrosion attack, wear during sliding of an archwire though brackets and breakdowns due to iatrogenic causes. The aim of this research was to analyse the influence of environmental effects on the corrosion and tribocorrosion properties of NiTi and stainless steel dental alloys. The effects of pH and fluorides on the electrochemical properties were studied using the cyclic potentiodynamic technique. The migration of ions from the alloy into saliva during exposure to saliva with and without the presence of wear was analysed using ICP-MS analyses. Auger spectroscopy was used to study the formation of a passive oxide layer on different dental alloys. It was found that lowering the pH preferentially affects the corrosion susceptibility of NiTi alloys, whereas stainless steel dental archwires are prone to local types of corrosion. The NiTi alloy is not affected by smaller increases of fluoride ions up to 0.024 M, while at 0.076 M (simulating the use of toothpaste) the properties are affected. A leaching test during wear-assisted corrosion showed that the concentrations of Ni ions released into the saliva exceeded the limit value of 0.5 mu g/cm(2)/week. The oxide films on the NiTi and stainless steel alloys after the tribocorrosion experiment were thicker than those exposed to saliva only. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:682 / 689
页数:8
相关论文
共 42 条
[1]   Influence of Soft Drinks with Low pH on Different Ni-Ti Orthodontic Archwire Surface Patterns [J].
Abalos, C. ;
Paul, A. ;
Mendoza, A. ;
Solano, E. ;
Palazon, C. ;
Gil, F. J. .
JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2013, 22 (03) :759-766
[2]  
Al Jabbari YS, 2014, J ADV PROSTHODONT, V6, P138
[3]   Friction coefficients and wear rates of different orthodontic archwires in artificial saliva [J].
Alfonso, M. V. ;
Espinar, E. ;
Llamas, J. M. ;
Ruperez, E. ;
Manero, J. M. ;
Barrera, J. M. ;
Solano, E. ;
Gil, F. J. .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2013, 24 (05) :1327-1332
[4]  
[Anonymous], 2004, OFF J EUR UNION
[5]   Electrochemical studies on the stability and corrosion resistance of titanium-based implant materials [J].
Aziz-Kerrzo, M ;
Conroy, KG ;
Fenelon, AM ;
Farrell, ST ;
Breslin, CB .
BIOMATERIALS, 2001, 22 (12) :1531-1539
[6]  
Chaturvedi Thakur Prasad, 2012, Indian J Dent Res, V23, P479, DOI 10.4103/0970-9290.104953
[7]   Characterization of Inclusions in VIM/VAR NiTi Alloys [J].
Coda, A. ;
Zilio, S. ;
Norwich, D. ;
Sczerzenie, F. .
JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2012, 21 (12) :2572-2577
[8]   Morphological characterization of as-received and in vivo orthodontic stainless steel archwires [J].
Daems, Julie ;
Celis, Jean-Pierre ;
Willems, Guy .
EUROPEAN JOURNAL OF ORTHODONTICS, 2009, 31 (03) :260-265
[9]   Development of an artificial saliva solution for studying the corrosion behavior of dental alloys [J].
Duffó, GS ;
Castillo, EQ .
CORROSION, 2004, 60 (06) :594-602
[10]   Assessing the biocompatibility of NiTi shape memory alloys used for medical applications [J].
Es-Souni, M ;
Es-Souni, M ;
Fischer-Brandies, H .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (03) :557-567