Two-Dimensional Shear-Wave Elastography for Kidney Stiffness Assessment

被引:18
作者
Grosu, Iulia [1 ]
Bob, Flaviu [1 ]
Sporea, Ioan [2 ]
Popescu, Alina [2 ]
Sirli, Roxana [2 ]
Schiller, Adalbert [1 ]
机构
[1] Victor Babes Univ Med & Pharm, Dept Nephrol, 156 L Rebreanu Bd, Timisara, Romania
[2] Victor Babes Univ Med & Pharm, Dept Gastroenterol & Hepatol, Timisara, Romania
关键词
chronic kidney disease; shear waves; shear-wave elastography; ultrasound elastography; TRANSIENT ELASTOGRAPHY; LIVER FIBROSIS; CLINICAL-USE; ULTRASOUND; ELASTICITY; EXPERIENCE; DIAGNOSIS; DISEASE; VALUES;
D O I
10.1097/RUQ.0000000000000461
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study aimed to analyze the utility of bidimensional shear-wave elastography for renal assessment and in the prediction of chronic kidney disease (CKD). The study included 92 subjects: 50 healthy volunteers and 42 patients with different degrees of CKD (mean age, 57.5 +/- 13.4; 50% were female), excluding those undergoing renal replacement therapies, obstructive pathology, or renal lithiasis. We performed kidney shear-wave velocity (KSWV) determinations in the midportion of the parenchyma of each kidney. The median values were expressed in meters per second. We obtained successful assessments in 94% of the cases for the right kidney (RK) and 90.2% for the left kidney (LK), with an intraclass correlation coefficient of 0.96 (RK) and 0.91 (LK). We obtained significantly lower KSWV values in the CKD lot as opposed to the healthy volunteers: RK: 1.38 +/- 0.1 versus 1.78 +/- 0.1 m/s, P = 0.05; LK: 1.37 +/- 0.1 m/s versus 1.72 +/- 0.1 m/s. We could predict the presence of CKD with a sensitivity of 89.2% and a specificity of 76.9% for a KSWV of less than 1.47 m/s, with a tendency of KSWV to decrease with CKD progression. Our study shows that KSWV measured using bidimensional shear-wave elastography decreases in patients with CKD compared with normal subjects, and that for a cutoff value of below 1.47 m/s we could predict, with a good sensitivity and specificity, the presence of CKD.
引用
收藏
页码:144 / 148
页数:5
相关论文
共 32 条
  • [1] Acoustic Radiation Force Impulse Elastography of the Kidneys Is Shear Wave Velocity Affected by Tissue Fibrosis or Renal Blood Flow?
    Asano, Kenichiro
    Ogata, Ai
    Tanaka, Keiko
    Ide, Yoko
    Sankoda, Akiko
    Kawakita, Chieko
    Nishikawa, Mana
    Ohmori, Kazuyoshi
    Kinomura, Masaru
    Shimada, Noriaki
    Fukushima, Masaki
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (05) : 793 - 801
  • [2] Tipping the balance from angiogenesis to fibrosis in CKD
    Ballermann, Barbara J.
    Obeidat, Marya
    [J]. KIDNEY INTERNATIONAL SUPPLEMENTS, 2014, 4 (01) : 45 - 52
  • [3] Batur A., 2018, ULTRASOUND Q
  • [4] Performance of 2D-SWE.GE for predicting different stages of liver fibrosis, using Transient Elastography as the reference method
    Bende, Felix
    IoanSporea
    Sirli, Roxana
    Popescu, Alina
    Mare, Ruxandra
    Miutescu, Bogdan
    Lupusoru, Raluca
    Moga, Tudor
    Pienar, Corina
    [J]. MEDICAL ULTRASONOGRAPHY, 2017, 19 (02) : 143 - 149
  • [5] ULTRASOUND-BASED SHEAR WAVE ELASTOGRAPHY IN THE ASSESSMENT OF PATIENTS WITH DIABETIC KIDNEY DISEASE
    Bob, Flaviu
    Grosu, Iulia
    Sporea, Ioan
    Bota, Simona
    Popescu, Alina
    Sima, Alexandra
    Sirli, Roxana
    Petrica, Ligia
    Timar, Romulus
    Schiller, Adalbert
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (10) : 2159 - 2166
  • [6] Relationship Between the Estimated Glomerular Filtration Rate and Kidney Shear Wave Speed Values Assessed by Acoustic Radiation Force Impulse Elastography
    Bob, Flaviu
    Bota, Simona
    Sporea, Ioan
    Sirli, Roxana
    Popescu, Alina
    Schiller, Adalbert
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2015, 34 (04) : 649 - 654
  • [7] Kidney Shear Wave Speed Values in Subjects with and without Renal Pathology and Inter-Operator Reproducibility of Acoustic Radiation Force Impulse Elastography (ARFI) - Preliminary Results
    Bob, Flaviu
    Bota, Simona
    Sporea, Ioan
    Sirli, Roxana
    Petrica, Ligia
    Schiller, Adalbert
    [J]. PLOS ONE, 2014, 9 (11):
  • [8] Meta-analysis: ARFI elastography versus transient elastography for the evaluation of liver fibrosis
    Bota, Simona
    Herkner, Harald
    Sporea, Ioan
    Salzl, Petra
    Sirli, Roxana
    Neghina, Adriana M.
    Peck-Radosavljevic, Markus
    [J]. LIVER INTERNATIONAL, 2013, 33 (08) : 1138 - 1147
  • [9] Evaluation of acoustic radiation force impulse imaging for the clinicopathological typing of renal fibrosis
    Cui, Guanghe
    Yang, Zhi
    Zhang, Wenxiao
    Li, Baowei
    Sun, Fang
    Xu, Cui
    Wang, Kun
    [J]. EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2014, 7 (01) : 233 - 235
  • [10] VALIDATION OF SHEAR WAVE ELASTOGRAPHY CUTOFF VALUES ON THE SUPERSONIC AIXPLORER FOR PRACTICAL CLINICAL USE IN LIVER FIBROSIS STAGING
    Dhyani, Manish
    Grajo, Joseph R.
    Bhan, Atul K.
    Corey, Kathleen
    Chung, Raymond
    Samir, Anthony E.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (06) : 1125 - 1133