A label-free immunosensor for diagnosis of dengue infection with simple electrical measurements

被引:40
作者
Fang, Xiaoqin [1 ]
Tan, Ooi Kiang [1 ]
Tse, Man Siu [1 ]
Ooi, Eng Eong [2 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[2] DSO Natl Labs, Def Med & Environm Res Inst, Singapore 117510, Singapore
关键词
Immunosensors; Dengue infection detection; Barium strontium titanate thin film; THIN-FILMS; VIRUS-INFECTION; HYDROGEN GAS; DEVICE; MICROBOLOMETERS; ANTIBODIES; (BA;
D O I
10.1016/j.bios.2009.09.037
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The interdigitated electrodes and electrical measurements for the diagnosis of dengue infection using antigen-antibody conjugation method are reported. As a proof of concept, pre-inactivated dengue virus was firstly immobilized indirectly onto the immunosensor surface, pre-coated with sol-gel derived barium strontium titanate (BST) thin film and modified with organic self-assembled monolayer (SAM) formed by 3-aminopropyltriethoxysilane (APTS) and a cross-linker glutaraldehyde over the interdigitated electrodes. The modified sensor surface served as selective sensing probe to capture/conjugate the dengue antibody molecules present in patient's serum. Our immunosensor is based on non-faradaic process, using only de-ionized water as electrolyte during the simple electrical measurements. Both ac impedance spectroscopy and dc I-V measurements between the electrodes gave a clearly discernable and repeatable signal to positively identify the presence of dengue antibody in the serum. Direct correlation was obtained between the signal outputs with respect to antibody concentrations. The measured signal changes in impedance/current without/with the presence of dengue antibody were attributed to the surface conductivity change upon biomolecules immobilization and the dipole-induced interfacial polarization potential at the SAM film/biomolecules interface. By monitoring the impedance or current change, the antibody molecules in the patient's serum could be positively detected. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1137 / 1142
页数:6
相关论文
共 33 条
[1]   Humidity sensing properties of (Ba, Sr) TiO3 thin films grown by hydrothermal-electrochemical method [J].
Agarwal, S ;
Sharma, GL .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 85 (03) :205-211
[2]   Electrical conduction in (Ba, Sr)TiO3 thin film MIS capacitor under humid conditions [J].
Agarwal, S ;
Sharma, GL ;
Manchanda, R .
SOLID STATE COMMUNICATIONS, 2001, 119 (12) :681-686
[3]   Diagnosis of dengue virus infection by detection of specific immunoglobulin M (IgM) and IgA antibodies in serum and saliva [J].
Balmaseda, A ;
Guzmán, MG ;
Hammond, S ;
Robleto, G ;
Flores, C ;
Téllez, Y ;
Videa, E ;
Saborio, S ;
Pérez, L ;
Sandoval, E ;
Rodriguez, Y ;
Harris, E .
CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2003, 10 (02) :317-322
[4]  
Barsoukov E, 2005, IMPEDANCE SPECTROSCOPY: THEORY, EXPERIMENT, AND APPLICATIONS, 2ND EDITION, pXII
[5]  
Berggren C, 2001, ELECTROANAL, V13, P173, DOI 10.1002/1521-4109(200103)13:3<173::AID-ELAN173>3.0.CO
[6]  
2-B
[7]   Immunodiagnosis of dengue virus infection using saliva [J].
Chakravarti, Anita ;
Matlani, Monika ;
Jain, Manisha .
CURRENT MICROBIOLOGY, 2007, 55 (06) :461-464
[8]   Detection of specific antibodies in saliva during Dengue infection [J].
Cuzzubbo, AJ ;
Vaughn, DW ;
Nisalak, A ;
Suntayakorn, S ;
Aaskov, J ;
Devine, PL .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (12) :3737-3739
[9]   Label-free impedance biosensors: Opportunities and challenges [J].
Daniels, Jonathan S. ;
Pourmand, Nader .
ELECTROANALYSIS, 2007, 19 (12) :1239-1257
[10]   Diagnosis of dengue infection by detecting specific immunoglobulin M antibodies in saliva samples [J].
de Oliveira, SA ;
Rodrigues, CVN ;
Camacho, LAB ;
Miagostovich, MP ;
Araújo, ESM ;
Nogueira, RMR .
JOURNAL OF VIROLOGICAL METHODS, 1999, 77 (01) :81-86