The energetic, exergetic, and mechanical comparison of two structurally optimized non-concentrating solar collectors for intermediate temperature applications

被引:10
作者
Gao, Datong [1 ]
Zhong, Shuai [1 ]
Ren, Xiao [2 ]
Kwan, Trevor Hocksun [1 ]
Pei, Gang [1 ]
机构
[1] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230027, Peoples R China
[2] China Univ Petr East China, Coll New Energy, Qingdao 266580, Peoples R China
基金
中国国家自然科学基金;
关键词
Solar energy; Intermediate temperature; Solar collector; Exergy; EVACUATED TUBE COLLECTORS; FLAT-PLATE COLLECTORS; THERMAL PERFORMANCE; HEAT-EXCHANGER; EFFICIENCY; DESIGN; NANOFLUIDS; ABSORBER; STORAGE; SYSTEM;
D O I
10.1016/j.renene.2021.12.025
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The highly efficient non-concentrating solar collector is a key component for increasing solar energy penetration at the district level, thereby achieving the "carbon neutrality " goal. The non-concentrating vacuum-type solar collector used for intermediate temperature (100-200 & DEG;C) applications is a promising technology that has not been sufficiently explored. In this paper, two structurally optimized non concentrating solar collectors have been meticulously analyzed from the perspective of structure, energy, exergy, surface stress, etc. Firstly, an outdoor experiment is executed to exhibit their thermodynamic behavior. Thermal resistance networks before and after their structural optimization are formed and the results indicate the thermal resistance that impedes solar collector heat loss has been enhanced by 3.83 and 4.17-fold, respectively. Next, energy and exergy flow charts are established to explain the thermal performance difference and the solar energy conversion in their respective internal components. Finally, the potential room for performance enhancement is further studied via the advanced exergy analysis method which reveals that the exergy destruction can be reduced by 17.74% and 13.90%, respectively. The results are essential for the further development of non-concentrating solar collectors in intermediate temperature applications, and it is also instrumental to realizing the decarbonization in district energy supplements. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:881 / 898
页数:18
相关论文
共 67 条
[1]   Energy and exergy analyses of nanofluid-filled parabolic trough solar collector with acentric absorber tube and insulator roof [J].
Abbasian Arani, Ali Akbar ;
Monfaredi, Farhad .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 145 (03) :787-816
[2]   Energy and exergy assessment of integrating reflectors on thermal energy storage of evacuated tube solar collector-heat pipe system [J].
Abo-Elfadl, Saleh ;
Hassan, Hamdy ;
El-Dosoky, M. F. .
SOLAR ENERGY, 2020, 209 :470-484
[3]   Performance evaluation of a solar adsorption chiller under different climatic conditions [J].
Alahmer, Ali ;
Wang, Xiaolin ;
Al-Rbaihat, Raed ;
Alam, K. C. Amanul ;
Saha, B. B. .
APPLIED ENERGY, 2016, 175 :293-304
[4]   Numerical study on performance improvement of a flat-plate solar collector filled with porous foam [J].
Anirudh, K. ;
Dhinakaran, S. .
RENEWABLE ENERGY, 2020, 147 :1704-1717
[5]  
[Anonymous], 2019, Statistical Review of World Energy, 2020 | 69th Edition, V68th
[6]   Comparative field performance study of flat plate and heat pipe evacuated tube collectors (ETCs) for domestic water heating systems in a temperate climate [J].
Ayompe, L. M. ;
Duffy, A. ;
Mc Keever, M. ;
Conlon, M. ;
McCormack, S. J. .
ENERGY, 2011, 36 (05) :3370-3378
[7]   How much work can be extracted from diluted solar radiation? [J].
Badescu, Viorel .
SOLAR ENERGY, 2018, 170 :1095-1100
[8]   Experimental and numerical performance analysis of a converging channel heat exchanger for PV cooling [J].
Baloch, Ahmer A. B. ;
Bahaidarah, Haitham M. S. ;
Gandhidasan, Palanichamy ;
Al-Sulaiman, Fahad A. .
ENERGY CONVERSION AND MANAGEMENT, 2015, 103 :14-27
[9]   A Practical Methodology for the Design and Cost Estimation of Solar Tower Power Plants [J].
Behar, Omar ;
Sbarbaro, Daniel ;
Moran, Luis .
SUSTAINABILITY, 2020, 12 (20) :1-16
[10]   High efficiency evacuated flat-plate solar collector for process steam production [J].
Benz, N ;
Beikircher, T .
SOLAR ENERGY, 1999, 65 (02) :111-118