Programmable control of column selectivity for temperature-programmed GC

被引:11
作者
Coutant, C [1 ]
Sacks, R [1 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
关键词
D O I
10.1021/ac000610h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A computer-driven pressure controller connected to the junction point of a series-coupled ensemble of two capillary GC columns having different stationary-phase selectivity is used to obtain on-the-fly (programmable) changes in ensemble selectivity. Changes in the junction-point pressure result in differential changes in the focal carrier gas velocity in the two columns, and this results in changes in the pattern of peaks eluting from the ensemble. When used with relatively fast temperature programming (30 degreesC/min), the pattern of eluting peaks can be very sensitive to the time at which a selectivity (junction-point pressure) change is implemented. These elution pattern changes are described for a set of six PCB congeners that elute with a small range of retention times. The components are considered as a group, and changes in their elution pattern are described for a single junction-point pressure change, which is implemented at various times after sample injection. If the pressure change is implemented after the components have migrated across the junction point, the final pressure has relatively little impact on the ensemble retention pattern. Pressure changes implemented prior to the components reaching the junction can have a large effect and usually result in a pattern of peaks similar to the pattern obtained when the final pressure is used for the entire separation. For pressure changes made when the group of components is near the junction point, the observed peak pattern may be very sensitive to the time of the pressure change. The time at which the junction-point pressure change occurs is varied in 1.0-s intervals. Artifacts such as peak doubling and peak focusing or broadening are observed if a migrating band is crossing the column junction point at the time of the programmed pressure change.
引用
收藏
页码:5450 / 5458
页数:9
相关论文
共 23 条
[1]   SEPARATION WINDOW DIAGRAMS FOR HIGH-SPEED GC [J].
AKARD, M ;
SACKS, R .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2733-2737
[2]   PRESSURE-TUNABLE SELECTIVITY FOR HIGH-SPEED GAS-CHROMATOGRAPHY [J].
AKARD, M ;
SACKS, R .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3036-3041
[3]  
Annino R, 1996, HRC-J HIGH RES CHROM, V19, P285
[4]   UTILITY OF MIXED PACKINGS IN GAS-LIQUID-CHROMATOGRAPHY [J].
CHIEN, CF ;
LAUB, RJ ;
KOPECNI, MM .
ANALYTICAL CHEMISTRY, 1980, 52 (09) :1402-1407
[5]   High-speed gas chromatography: an overview of various concepts [J].
Cramers, CA ;
Janssen, HG ;
van Deursen, MM ;
Leclercq, PA .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :315-329
[6]  
DANDENEAU R, 1979, AM LAB, V11, P61
[7]   GAS-CHROMATOGRAPHIC COLUMNS WITH ADJUSTABLE SEPARATION CHARACTERISTICS [J].
DEANS, DR ;
SCOTT, I .
ANALYTICAL CHEMISTRY, 1973, 45 (07) :1137-1141
[8]  
Desty D. H, 1962, GAS CHROMATOGRAPHY, P105
[9]   THE ROLE OF SELECTIVITY IN GAS-CHROMATOGRAPHY [J].
FREEMAN, RR ;
KUKLA, D .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1986, 24 (09) :392-395
[10]   HIGH-SPEED GAS-CHROMATOGRAPHY - THEORETICAL AND PRACTICAL ASPECTS [J].
GASPAR, G .
JOURNAL OF CHROMATOGRAPHY, 1991, 556 (1-2) :331-351