Geometric verification of the validity of Finite Element Method analysis of Abdominal Aortic Aneurysms based on Magnetic Resonance Imaging

被引:0
作者
Domagala, Zuzanna [1 ]
Stepak, Hubert [2 ]
Drapikowski, Pawel [1 ]
Kociemba, Anna [3 ]
Pyda, Malgorzata [3 ]
Karmelita-Katulska, Katarzyna [4 ]
Dzieciuchowicz, Lukasz [2 ]
Oszkinis, Grzegorz [2 ]
机构
[1] Poznan Univ Tech, Fac Elect Engn, Inst Control & Informat Engn, Ul Piotrowo 3a, PL-60965 Poznan, Poland
[2] Poznan Univ Med Sci, Dept Gen & Vasc Surg, Poznan, Poland
[3] Poznan Univ Med Sci, Dept Cardiol, Clin Cardiol 1, Poznan, Poland
[4] Poznan Univ Med Sci, Dept Gen Radiol, Poznan, Poland
关键词
FE simulation; Abdominal aortic aneurysm; Patient-specific modeling; BLACK BLOOD MRI; WALL STRESS; INTRALUMINAL THROMBUS; MECHANICAL-PROPERTIES; RUPTURE RISK; BIOMECHANICAL BEHAVIOR; FAILURE PROPERTIES; PREDICTION; THICKNESS; DIAMETER;
D O I
10.1016/j.bbe.2018.04.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The currently used criterion of maximum transverse diameter for the Abdominal Aortic Aneurysm treatment has some limitations. Attempts to create individualized, therapeutic strategies are being conducted, including biomechanical assessment of rupture risk of an aneurysm based on the Finite Element Analysis of the geometric models. The usual approach is to use the results of the computed tomography imaging to build a three-dimensional model of the aneurysm. The FEA is then performed and the resulting stress is analysed to estimate the risk of rupture. Although such an approach brings significant improvements over the traditional maximum diameter method, it is difficult to ensure the validity of the assumptions made. This paper presents a method to evaluate the correctness of such an approach. The emergence of gated Magnetic Resonance Imaging allows registering aneurysm in both the systolic and diastolic phase of cardiac cycle. The corresponding geometric models are built and the results of the FEA applied to the diastolic model are compared with the actual deformation of the aneurysm observed in the patient's body. Thus, it is possible to verify whether the individualized diagnostic approach applied to a specific patient was correct. The geometry of the reference and the analysed models were compared using the Differential Surface Area Method. The average geometry error equals 1.65%. In the best case the error amounts to 1.04%, in the worst to 3.00%. The obtained results provide evidence that the Finite Element Analysis is a reliable method and can be potentially used for individualized diagnostics and treatment. (C) 2018 Nalecz Institute of Biocybernetics and Biomedical Engineering of the Polish Academy of Sciences. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:544 / 555
页数:12
相关论文
共 65 条
[1]   3-D reconstruction of tissue components for atherosclerotic human arteries using ex vivo high-resolution MRI [J].
Auer, M ;
Stollberger, R ;
Regitnig, P ;
Ebner, F ;
Holzapfel, GA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (03) :345-357
[2]   Reconstruction and Finite Element Mesh Generation of Abdominal Aortic Aneurysms From Computerized Tomography Angiography Data With Minimal User Interactions [J].
Auer, M. ;
Gasser, T. Christian .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (04) :1022-1028
[3]  
Bal-Theoleyre L, 2017, EUR HEART J, V38, P130
[4]   A computational method to assess the in vivo stresses and unloaded configuration of patient-specific blood vessels [J].
Bols, J. ;
Degroote, J. ;
Trachet, B. ;
Verhegghe, B. ;
Segers, P. ;
Vierendeels, J. .
JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 2013, 246 :10-17
[5]   Risk factors for aneurysm rupture in patients kept under ultrasound surveillance [J].
Brown, LC ;
Powell, JT .
ANNALS OF SURGERY, 1999, 230 (03) :289-296
[6]  
Conlisk N, 2017, J CARDIOVASC T RES
[7]   Interactive segmentation of abdominal aortic aneurysms in CTA images [J].
de Bruijne, M ;
van Ginneken, B ;
Viergever, MA ;
Niessen, WJ .
MEDICAL IMAGE ANALYSIS, 2004, 8 (02) :127-138
[8]   Patient-specific initial wall stress in abdominal aortic aneurysms with a backward incremental method [J].
de Putter, S. ;
Wolters, B. J. B. M. ;
Rutten, M. C. M. ;
Breeuwer, M. ;
Gerritsen, F. A. ;
van de Vosse, F. N. .
JOURNAL OF BIOMECHANICS, 2007, 40 (05) :1081-1090
[9]   Computational Biomechanics-Based Rupture Prediction of Abdominal Aortic Aneurysms [J].
Doyle, Barry J. ;
Miller, Karol ;
Newby, David E. ;
Hoskins, Peter R. .
JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (01) :121-124
[10]   Identification of rupture locations in patient-specific abdominal aortic aneurysms using experimental and computational techniques [J].
Doyle, Barry J. ;
Cloonan, Aidan J. ;
Walsh, Michael T. ;
Vorp, David A. ;
McGloughlin, Timothy M. .
JOURNAL OF BIOMECHANICS, 2010, 43 (07) :1408-1416