Preoperative Digital Three-Dimensional Planning for Rhinoplasty

被引:42
作者
Moscatiello, Fabrizio [1 ]
Herrero Jover, Javier [1 ]
Gonzalez Ballester, Miguel Angel [2 ]
Carreno Hernandez, Encarna [1 ]
Piombino, Pasquale [3 ]
Califano, Luigi [3 ]
机构
[1] Ctr Med Teknon, Dept Plast Surg, Barcelona 08022, Spain
[2] Alma IT Syst, Barcelona 08022, Spain
[3] Univ Naples Federico 2, Dept Maxillofacial Surg, I-80131 Naples, Italy
关键词
Preoperative digital planning; Rhinoplasty; Three-dimensional planning; FACIAL PLASTIC-SURGERY; PRECISION RHINOPLASTY; COMPUTER; AESTHETICS;
D O I
10.1007/s00266-009-9455-4
中图分类号
R61 [外科手术学];
学科分类号
摘要
This report describes preoperative digital planning for rhinoplasty using a new three-dimensional (3D) radiologic viewer that allows both patients and surgeons to visualize on a common monitor the 3D real aspect of the nose in its inner and outer sides. In the period 2002 to 2008, 210 patients underwent rhinoplasty procedures in the authors' clinic. The patients were randomly divided into three groups according to the type of preoperative planning used: photos only, a simulated result by Adobe Photoshop, or the 3D radiologic viewer. The parameters evaluated included the number of patients that underwent surgery after the first consultation, the number of patients who asked for a reintervention, patient satisfaction (according to a test given to the patients 12 months postoperatively), the surgical time required for a functional intervention, and the improvement in nasal function by postoperative rhinomanometry and subjective evaluation. Computer-aided technologies led to a higher number of patients deciding to undergo a rhinoplasty. Simulation of the postoperative results was not as useful in the postoperative period due to the higher number of reintervention requests. The patients undergoing rhinoplasties preferred new technologies in the preoperative period. The advantages of using the 3D radiologic viewer included improved preoperative planning, reduction in intraoperative stress, a higher number of patients undergoing surgery, reduction in postoperative surgical corrections, reduction in surgical time for the functional intervention, a higher rate of improvement in nasal function, a higher percentage of postoperative satisfaction, and reduced costs.
引用
收藏
页码:232 / 238
页数:7
相关论文
共 25 条
[1]   PREDICTABILITY OF THE COMPUTER IMAGING-SYSTEM IN PRIMARY RHINOPLASTY [J].
BRONZ, G .
AESTHETIC PLASTIC SURGERY, 1994, 18 (02) :175-181
[2]   RHINOPLASTY - A PRACTICAL GUIDE FOR SURGICAL PLANNING [J].
BYRD, HS ;
HOBAR, PC .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1993, 91 (04) :642-654
[3]  
CHATFIELD C, 1983, STAT TECHNOLOGY, P148
[4]   Legal issues of computer imaging in plastic surgery: A primer [J].
Chavez, AE ;
Dagum, P ;
Koch, J ;
Newman, JP .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 100 (06) :1601-1608
[5]   A MODEL FOR PLANNING RHINOPLASTY [J].
CONSTANTIAN, MB .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1987, 79 (03) :472-481
[6]  
FARKAS LG, 1985, PLAST RECONSTR SURG, V75, P328, DOI 10.1097/00006534-198503000-00005
[7]  
FARKAS LG, 1987, CLIN PLAST SURG, V14, P599
[8]  
GONZALEZULLOA M, 1962, PLAST RECONSTR SURG, V29, P2
[9]  
GREGORY M, 2002, PLAST RECONSTR SURG, V109, P1421
[10]   PRECISION RHINOPLASTY .2. PREDICTION [J].
GUYURON, B .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1988, 81 (04) :500-505