Can [F-18] fluorodeoxyglucose positron emission tomography replace sentinel lymph node biopsy for the detection of axillary metastases in patients with early-stage breast cancer?

被引:2
|
作者
Gorgulu, Semih [1 ]
Can, Mehmet Fatih [1 ]
Hancerliogullari, Oguz [1 ]
Arslan, Nuri [2 ]
Ozturk, Erkan [1 ]
Ozturk, Emel [3 ]
Balkan, Muejdat [1 ]
Tufan, Turgut [1 ]
机构
[1] Gulhane Mil Med Acad, Dept Gen Surg, TR-06018 Ankara, Turkey
[2] Gulhane Mil Med Acad, Dept Nucl Med, TR-06018 Ankara, Turkey
[3] Ufuk Univ, Dept Nucl Med, Fac Med, TR-06520 Ankara, Turkey
关键词
Breast cancer; sentinel lymph node biopsy; positron emission tomography; axillary metastasis; FDG-PET; 2-DEOXY-2-FLUORO-D-GLUCOSE PET; CLINICAL-ONCOLOGY; DISSECTION; INVOLVEMENT; CARCINOMA; SURGERY; SURVIVAL; SIZE;
D O I
10.3906/sag-0803-10
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: To investigate the value of fluorodeoxyglucose positron emission tomography (FDG-PET) in detecting axillary involvement, and to compare its accuracy with sentinel lymph node biopsy (SLNB) in patients with clinically early-stage breast cancer. Materials and methods: Twenty-eight female patients with histologically-confirmed T1-2 breast cancer who were scheduled to have SLNB were included in the study. FDG-PET images were obtained 1-7 days prior to surgery with an intravenous injection of 370 MBq of FDG, while plasma glucose levels were maintained below 120 mg/dL. All the images were interpreted by 2 independent nuclear medicine specialists, who were blinded to the histological diagnoses. SLNB was performed in standard fashion with peri-tumoral injection of isosulphan blue dye. In all cases, a level I-II axillary dissection was performed following SLNB. Sentinel nodes were processed after formalin fixation; no frozen sections were used. Results: Thirteen (46%) patients were found to have axillary involvement. SLNB (an average of 2.3 LNs removed per patient) demonstrated metastases in all 13 patients. The diagnostic accuracy of FDG-PET was as follows: true-positive in 4 out of 13 patients (overall sensitivity = 31%), false-negative in 1 patient with metastasis (overall specificity = 94%), positive predictive value = 80%, negative predictive value = 63%, and accuracy = 68%. Conclusion: FDG-PET appears to be significantly less accurate than SLNB at detecting axillary metastases. In patients with an axillary-positive PET scan, however, axillary lymph node dissection may be performed without prior SLNB.
引用
收藏
页码:17 / 23
页数:7
相关论文
共 50 条
  • [1] Evaluation of Fluorodeoxyglucose Positron Emission Tomography in the Detection of Axillary Lymph Node Metastases in Patients With Early-Stage Breast Cancer
    Emmanuel Barranger
    Dany Grahek
    Martine Antoine
    Françoise Montravers
    Jean-Noel Talbot
    Serge Uzan
    Annals of Surgical Oncology, 2003, 10 : 622 - 627
  • [2] Evaluation of fluorodeoxyglucose positron emission tomography in the detection of axillary lymph node metastases in patients with early-stage breast cancer
    Barranger, E
    Grahek, D
    Antoine, M
    Montravers, F
    Talbot, JN
    Uzan, S
    ANNALS OF SURGICAL ONCOLOGY, 2003, 10 (06) : 622 - 627
  • [3] Comparison of Sentinel Lymph Node Sampling with Positron Emission Tomography in the Evaluation of Axillary Lymph Node Involvement in Breast Cancer Patients
    Ozsoy, Mehmet Sait
    Demir, Mustafa
    Baysal, Hakan
    Tatoglu, Mehmet Tarik
    Buyuker, Fatih
    Sermet, Medeni
    Eren, Tunc
    Ekinci, Ozgur
    Alimoglu, Orhan
    BANGLADESH JOURNAL OF MEDICAL SCIENCE, 2024, 23 (04): : 1083 - 1094
  • [4] Omitting Sentinel Lymph Node Biopsy in Early-Stage Breast Cancer Patients
    Thompson, Danielle
    Yao, Katharine
    CURRENT BREAST CANCER REPORTS, 2024, 16 (03) : 302 - 310
  • [5] Positron Emission Tomography-Computed Tomography in the Detection of Axillary Lymph Node Metastasis in Patients with Early Stage Breast Cancer
    Chae, Byung Joo
    Bae, Ja Seong
    Kang, Bong Joo
    Kim, Sung Hoon
    Jung, Sang Seol
    Song, Byung Joo
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2009, 39 (05) : 284 - 289
  • [6] Detection of Axillary Lymph Node Involvement in Early-Stage Breast Cancer: Comparison between Staging 18F-2-Fluoro-2-Deoxy-D-Glucose Positron Emission Tomography-Computed Tomography Scans, Mammography, and Sentinel Lymph Node Biopsy
    Gupta, Raju
    Das, Jayanta
    Sinha, Sayantani
    Agarwal, Sanjit
    Sharma, Abhisekh
    Ahmed, Rosina
    Chanda, Aditi
    Arun, Indu
    Ray, Soumendranath
    INDIAN JOURNAL OF NUCLEAR MEDICINE, 2023, 38 (03): : 249 - 254
  • [7] A prospective evaluation of positron emission tomography scanning, sentinel lymph node biopsy, and standard axillary dissection for axillary staging in patients with early stage breast cancer
    Lovrics, PJ
    Chen, V
    Coates, G
    Cornacchi, SD
    Goldsmith, CH
    Law, C
    Levine, MN
    Sanders, K
    Tandan, VR
    ANNALS OF SURGICAL ONCOLOGY, 2004, 11 (09) : 846 - 853
  • [8] A Prospective Evaluation of Positron Emission Tomography Scanning, Sentinel Lymph Node Biopsy, and Standard Axillary Dissection for Axillary Staging in Patients with Early Stage Breast Cancer
    Peter J. Lovrics
    Vicky Chen
    Geoff Coates
    Sylvie D. Cornacchi
    Charlie H. Goldsmith
    Calvin Law
    Mark N. Levine
    Ken Sanders
    Ved R. Tandan
    Annals of Surgical Oncology, 2004, 11 : 846 - 853
  • [9] Can Axillary Lymph Node Dissection Be Safely Omitted for Early-Stage Breast Cancer Patients with Sentinel Lymph Node Micrometastasis?
    Damle, Sameer
    Teal, Christine B.
    ANNALS OF SURGICAL ONCOLOGY, 2009, 16 (12) : 3215 - 3216
  • [10] Axillary Lymph Node Status in Early-Stage Breast Cancer Patients with Sentinel Node Micrometastases (0.2-2 mm)
    Bargehr, Johannes
    Edlinger, Michael
    Hubalek, Michael
    Marth, Christian
    Reitsamer, Roland
    BREAST CARE, 2013, 8 (03) : 187 - 191