Multicentre validation of IMRT pre-treatment verification: Comparison of in-house and external audit

被引:27
作者
Jornet, Nuria [1 ]
Carrasco, Pablo [1 ]
Beltran, Merce [2 ]
Francisco Calvo, Juan [3 ]
Escude, Lluis [4 ]
Hernandez, Victor [5 ]
Quera, Jaume [6 ]
Saez, Jordi [2 ]
机构
[1] Hosp Santa Creu & Sant Pau, Serv Radiofis & Radioproteccio, Barcelona, Spain
[2] Hosp Vall dHebro, Serv Fis, Barcelona, Spain
[3] Hosp Quiron, Serv Oncol Radioterap, Barcelona, Spain
[4] Clin Teknon, Serv Oncol Radioterap, Barcelona, Spain
[5] Hosp St Joan, Serv Fis, Reus, Spain
[6] Hosp Esperanza, Serv Oncol Radioterap, Barcelona, Spain
关键词
IMRT; Audit; Quality assurance; MODULATED RADIATION-THERAPY; RADIOCHROMIC FILM DOSIMETRY; QUALITY-ASSURANCE; EBT2; FILM; RADIOTHERAPY; COMPLEXITY; INDEX; QA;
D O I
10.1016/j.radonc.2014.06.016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: We performed a multicentre intercomparison of IMRT optimisation and dose planning and IMRT pre-treatment verification methods and results. The aims were to check consistency between dose plans and to validate whether in-house pre-treatment verification results agreed with those of an external audit. Materials and methods: Participating centres used two mock cases (prostate and head and neck) for the intercomparison and audit. Compliance to dosimetric goals and total number of MU per plan were collected. A simple quality index to compare the different plans was proposed. We compared gamma index pass rates using the centre's equipment and methodology to those of an external audit. Results: While for the prostate case, all centres fulfilled the dosimetric goals and plan quality was homogeneous, that was not the case for the head and neck case. The number of MU did not correlate with the plan quality index. Pre-treatment verifications results of the external audit did not agree with those of the in-house measurements for two centres: being within tolerance for in-house measurements and unacceptable for the audit or the other way round. Conclusions: Although all plans fulfilled dosimetric constraints, plan quality is highly dependent on the planner expertise. External audits are an excellent tool to detect errors in IMRT implementation and cannot be replaced by intercomparison using results obtained by centres. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:381 / 388
页数:8
相关论文
共 24 条
  • [1] Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance
    Aland, T.
    Kairn, T.
    Kenny, J.
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2011, 34 (02) : 251 - 260
  • [2] [Anonymous], GUID VER IMRT
  • [3] A national dosimetric audit of IMRT
    Budgell, Geoff
    Berresford, Joe
    Trainer, Michael
    Bradshaw, Ellie
    Sharpe, Peter
    Williams, Peter
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 (02) : 246 - 252
  • [4] Dosimetry audit for a multi-centre IMRT head and neck trial
    Clark, Catharine H.
    Hansen, Vibeke Nordmark
    Chantler, Hannah
    Edwards, Craig
    James, Hayley V.
    Webster, Gareth
    Miles, Elizabeth A.
    Urbano, M. Teresa Guerrero
    Bhide, Shree A.
    Bidmead, A. Margaret
    Nutting, Christoper M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 93 (01) : 102 - 108
  • [5] IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119
    Ezzell, Gary A.
    Burmeister, Jay W.
    Dogan, Nesrin
    LoSasso, Thomas J.
    Mechalakos, James G.
    Mihailidis, Dimitris
    Molineu, Andrea
    Palta, Jatinder R.
    Ramsey, Chester R.
    Salter, Bill J.
    Shi, Jie
    Xia, Ping
    Yue, Ning J.
    Xiao, Ying
    [J]. MEDICAL PHYSICS, 2009, 36 (11) : 5359 - 5373
  • [6] An inter-centre quality assurance network for IMRT verification: Results of the ESTRO QUASIMODO project
    Gillis, S
    De Wagter, C
    Bohsung, J
    Perrin, B
    Williams, P
    Mijnheer, BJ
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 (03) : 340 - 353
  • [7] Technical Note: Homogeneity of Gafchromic® EBT2 film
    Hartmann, Bernadette
    Martisikova, Maria
    Jaekel, Oliver
    [J]. MEDICAL PHYSICS, 2010, 37 (04) : 1753 - 1756
  • [8] A comparison of the gamma index analysis in various commercial IMRT/VMAT QA systems
    Hussein, Mohammad
    Rowshanfarzad, Pejman
    Ebert, Martin A.
    Nisbet, Andrew
    Clark, Catharine H.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2013, 109 (03) : 370 - 376
  • [9] ICRU, 2010, J. ICRU, V10, DOI [10.1093/jicru_ndq002, DOI 10.1093/JICRU_NDQ002, 10.1093/jicrundq002, DOI 10.1093/JICRUNDQ002]
  • [10] IPEM IMRT Working Party, 2008, 96 IPEM IMRT