Accuracy of theoretical IOL formulas for Panoptix intraocular lens according to axial length

被引:13
|
作者
Choi, Ayoung [1 ]
Kwon, Hyunggoo [1 ]
Jeon, Sohee [1 ]
机构
[1] Keye Eye Ctr, 326 Teheran Ro, Seoul, South Korea
关键词
D O I
10.1038/s41598-021-86604-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The accuracy of intraocular lens (IOL) calculations is suboptimal for long or short eyes, which results in a low visual quality after multifocal IOL implantation. The purpose of the present study is to evaluate the accuracy of IOL formulas (Barrett Universal II, SRK/T, Holladay 1, Hoffer Q, and Haigis) for the Acrysof IQ Panoptix TFNT IOL (Alcon Laboratories, Inc, Fort Worth, Texas, United States) implantation based on the axial length (AXL) from a large cohort of 2018 cases and identify the factors that are associated with a high mean absolute error (MAE). The Barrett Universal II showed the lowest MAE in the normal AXL group (0.30 +/- 0.23), whereas the Holladay 1 and Hoffer Q showed the lowest MAE in the short AXL group (0.32 +/- 0.22 D and 0.32 +/- 0.21 D, respectively). The Haigis showed the lowest MAE in the long AXL group (0.24 +/- 0.19 D). The Barrett Universal II did not perform well in short AXL eyes with higher astigmatism (P=0.013), wider white-to-white (WTW; P<0.001), and shorter AXL (P=0.016). Study results suggest that the Barrett Universal II performed best for the TFNT IOL in the overall study population, except for the eyes with short AXL, particularly when the eyes had higher astigmatism, wider WTW, and shorter AXL.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Reply to Comment on: Accuracy of Intraocular Lens Formulas in Eyes With Keratoconus
    Wang, Kendrick M.
    Jun, Albert S.
    Ladas, John G.
    Siddiqui, Aazim A.
    Woreta, Fasika
    Srikumaran, Divya
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 218 : 355 - 356
  • [42] Comparison of Three Formulas for Intraocular Lens Power Formula Accuracy
    Lee, Ki Woong
    Kim, Jinsoo
    Kim, Dong Hyun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (01): : 27 - 33
  • [43] Accuracy of Intraocular Lens Power Formulas Modified for Patients with Keratoconus
    Kane, Jack X.
    Connell, Benjamin
    Yip, Harry
    McAlister, James C.
    Beckingsale, Peter
    Snibson, Grant R.
    Chan, Elsie
    OPHTHALMOLOGY, 2020, 127 (08) : 1037 - 1042
  • [44] Intraocular lens power formula accuracy: Comparison of 7 formulas
    Kane, Jack X.
    van Heerden, Anton
    Atik, Alp
    Petsoglou, Constantinos
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (10): : 1490 - 1500
  • [45] Accuracy of New Intraocular Lens Power Calculation Formulas: A Lens Thickness Study
    Taroni, Leonardo
    Hoffer, Kenneth J.
    Lupardi, Enrico
    Barboni, Piero
    Savini, Giacomo
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (03) : 202 - 206
  • [46] Comparison of the accuracy of 11 intraocular lens power calculation formulas
    Carmona-Gonzalez, David
    Castillo-Gomez, Alfredo
    Palomino-Bautista, Carlos
    Romero-Dominguez, Marta
    Gutierrez-Moreno, Maria Angeles
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (05) : 2370 - 2376
  • [47] Comparative Accuracy Of Five Modern Toric Intraocular Lens Formulas
    Yang, Soonwon
    Han, Hyoji
    Lee, Hyun soo
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2025, 274 : 1 - 8
  • [48] Evaluation of the Accuracy of Intraocular Lens Power Calculation Formulas in Phacovitrectomy
    Tanaka, Yuichiro
    Kamiya, Kazutaka
    Igarahi, Akihito
    Shoji, Nobuyuki
    Tsuchiya, Hiroshi
    Takahashi, Shinya
    Ishikawa, Eri
    Kozawa, Tadahiko
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (08) : 2197 - 2208
  • [49] Intraocular lens power calculation formula accuracy: Comparison of 12 formulas for a trifocal hydrophilic intraocular lens
    Rocha-de-Lossada, Carlos
    Colmenero-Reina, Elvira
    Flikier, David
    Castro-Alonso, Francisco-Javier
    Rodriguez-Raton, Alvaro
    Garcia-Madrona, Jose-Luis
    Peraza-Nieves, Jorge
    Sanchez-Gonzalez, Jose-Maria
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (06) : 2981 - 2988
  • [50] Effect of axial length and keratometry measurement error on intraocular lens implant power prediction formulas in pediatric patients
    Eibschitz-Tsimhoni, Maya
    Tsimhoni, Omer
    Archer, Steven M.
    Del Monte, Monte A.
    JOURNAL OF AAPOS, 2008, 12 (02): : 173 - 176