Accuracy of theoretical IOL formulas for Panoptix intraocular lens according to axial length

被引:13
|
作者
Choi, Ayoung [1 ]
Kwon, Hyunggoo [1 ]
Jeon, Sohee [1 ]
机构
[1] Keye Eye Ctr, 326 Teheran Ro, Seoul, South Korea
关键词
D O I
10.1038/s41598-021-86604-5
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The accuracy of intraocular lens (IOL) calculations is suboptimal for long or short eyes, which results in a low visual quality after multifocal IOL implantation. The purpose of the present study is to evaluate the accuracy of IOL formulas (Barrett Universal II, SRK/T, Holladay 1, Hoffer Q, and Haigis) for the Acrysof IQ Panoptix TFNT IOL (Alcon Laboratories, Inc, Fort Worth, Texas, United States) implantation based on the axial length (AXL) from a large cohort of 2018 cases and identify the factors that are associated with a high mean absolute error (MAE). The Barrett Universal II showed the lowest MAE in the normal AXL group (0.30 +/- 0.23), whereas the Holladay 1 and Hoffer Q showed the lowest MAE in the short AXL group (0.32 +/- 0.22 D and 0.32 +/- 0.21 D, respectively). The Haigis showed the lowest MAE in the long AXL group (0.24 +/- 0.19 D). The Barrett Universal II did not perform well in short AXL eyes with higher astigmatism (P=0.013), wider white-to-white (WTW; P<0.001), and shorter AXL (P=0.016). Study results suggest that the Barrett Universal II performed best for the TFNT IOL in the overall study population, except for the eyes with short AXL, particularly when the eyes had higher astigmatism, wider WTW, and shorter AXL.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Accuracy of Intraocular Lens Formulas in Eyes With Keratoconus
    Wang, Kendrick M.
    Jun, Albert S.
    Ladas, John G.
    Siddiqui, Aazim A.
    Woreta, Fasika
    Srikumaran, Divya
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 212 : 26 - 33
  • [22] Accuracy of common IOL power formulas in 611 eyes based on axial length and corneal power ranges
    Roeggla, Veronika
    Langenbucher, Achim
    Leydolt, Christina
    Schartmueller, Daniel
    Schwarzenbacher, Luca
    Abela-Formanek, Claudette
    Menapace, Rupert
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2021, 105 (12) : 1661 - 1665
  • [23] Effect of anterior chamber depth on predictive accuracy of seven intraocular lens formulas in eyes with axial length less than 22 mm
    Shrivastava, Ankur K.
    Behera, Pranayee
    Kacher, Rajaram
    Kumar, Binod
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 1579 - 1586
  • [24] To compare the accuracy of intraocular lens calculation formulas in the prediction of postoperative refraction in eyes with short axial length (&lt;22mm)
    Shirke, Sheetal
    Gupta, Nishant
    Ahmed, Suheb
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [25] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Zhao, Jing
    Liu, Liang-Ping
    Cheng, Huan-Huan
    Li, Jian-Bing
    Han, Xiao-Tong
    Liu, Yu
    Wu, Ming-Xing
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (09) : 1378 - 1384
  • [26] Accuracy of Modified Axial Length Adjustment for Intraocular Lens Power Calculation in Chinese Axial Myopic Eyes
    Cheng, Huanhuan
    Liu, Liangping
    Sun, Ao
    Wu, Mingxing
    CURRENT EYE RESEARCH, 2020, 45 (07) : 827 - 833
  • [27] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Jing Zhao
    Liang-Ping Liu
    Huan-Huan Cheng
    Jian-Bing Li
    Xiao-Tong Han
    Yu Liu
    Ming-Xing Wu
    International Journal of Ophthalmology, 2020, (09) : 1378 - 1384
  • [28] Intraocular lens movement in different axial length
    Peng, Manqiang
    Khan, Muhammad Ahmad
    Huang, Xuetao
    Lin, Ding
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [29] Accuracy of intraocular lens power calculations in eyes with axial length &lt;22.00 mm
    Day, Alexander C.
    Foster, Paul J.
    Stevens, Julian D.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (09): : 855 - 862
  • [30] Comment on: Accuracy of Intraocular Lens Formulas in Eyes With Keratoconus
    Gonzalez-Lubcke, Eduardo
    Kahuam-Lopez, Nicolas
    Navas, Alejandro
    Ramirez-Miranda, Arturo
    Graue-Hernandez, Enrique O.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 218 : 354 - 355