Design and evaluation of a condensation particle counter with high performance for single-particle counting

被引:4
|
作者
Wang, Wenyu [1 ,2 ]
Zhao, Xin [2 ]
Zhang, Jiaoshi [2 ,3 ]
Yang, Yixin [1 ,2 ]
Yu, Tongzhu [2 ,3 ]
Bian, Jiejie [1 ,2 ]
Gui, Huaqiao [2 ,3 ]
Liu, Jianguo [1 ,2 ,3 ]
机构
[1] Univ Sci & Technol China, Coll Environm Sci & Optoelect Technol, Hefei, Anhui, Peoples R China
[2] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Environm Opt & Technol, Hefei, Anhui, Peoples R China
[3] Chinese Acad Sci, Inst Urban Environm, Ctr Excellence Reg Atmospher Environm, Xiamen, Fujian, Peoples R China
关键词
Condensation particle counter; detection efficiency; particle electronic pulse; single-particle counting; EFFICIENCY; FLOW;
D O I
10.1080/10739149.2019.1687516
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A full-flow butanol-based condensation particle counter (CPC) with a concentration range from 0 to 2 x 10(5) particles/cm(3) was developed to measure nanoparticles down to 4.5 nm. Good single-particle counting performance was achieved by developing a high-speed optical particle detection module. The pulse width of single particle was approximately 1.2 mu s at a flow rate of 0.3 L/min. By establishing a heat and mass transfer model using the COMSOL simulation software, the effects of temperature and aerosol sampling flow on the condensation growth of nanoparticles were studied. The performance of developed condensation particle counter was evaluated through a series of experiments to determine the coincidence probability, concentration range, and detection efficiency (cutoff diameter). At concentrations of 1.5 x 10(4) particles/cm(3) and 2 x 10(5) particles/cm(3), the coincidence probabilities of the developed condensation particle counter were 9.5% and 55%, respectively. A 99.9% (R-2) statistical correlation was obtained between the pulse-time corrected concentration of the developed condensation particle counter and the standard reference concentration. Finally, the experimental results showed that the developed condensation particle counter cutoff diameter, at which the detection efficiency was 50%, for sucrose aerosol particles was 4.5 nm.
引用
收藏
页码:212 / 229
页数:18
相关论文
共 50 条
  • [1] Development and evaluation of an online monitoring single-particle optical particle counter with polarization detection
    Yao, Weijie
    Pan, Xiaole
    Tian, Yu
    Liu, Hang
    Zhang, Yuting
    Lei, Shandong
    Zhang, Junbo
    Zhang, Yinzhou
    Wu, Lin
    Sun, Yele
    Wang, Zifa
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2024, 138 : 585 - 596
  • [2] CONTINUOUS-FLOW, SINGLE-PARTICLE-COUNTING CONDENSATION NUCLEUS COUNTER
    AGARWAL, JK
    SEM, GJ
    JOURNAL OF AEROSOL SCIENCE, 1980, 11 (04) : 343 - &
  • [3] Counting efficiency measurements for a new condensation particle counter
    Baltzer, S.
    Onel, S.
    Weiss, M.
    Seipenbusch, M.
    JOURNAL OF AEROSOL SCIENCE, 2014, 70 : 11 - 14
  • [4] Accelerated durability test of a condensation particle counter with high particle loading
    Sakurai, H. (hiromu.sakurai@aist.go.jp), 1600, Elsevier Ltd (75):
  • [5] Accelerated durability test of a condensation particle counter with high particle loading
    Hama, Naoya
    Funato, Koji
    Sakurai, Hiromu
    JOURNAL OF AEROSOL SCIENCE, 2014, 75 : 17 - 21
  • [6] Optimizing VLHC single-particle performance
    Talman, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 450 (2-3): : 207 - 222
  • [7] Design and performance characteristics of a condensation particle counter UF-02proto
    Mordas, G
    Kulmala, M
    Petäjä, T
    AAlto, PP
    Matulevicius, V
    Grigoraitis, V
    Ulevicius, V
    Grauslys, V
    Ukkonen, A
    Hämeri, K
    BOREAL ENVIRONMENT RESEARCH, 2005, 10 (06): : 543 - 552
  • [8] Performance evaluation of a recently developed water-based condensation particle counter
    Biswas, S
    Fine, PM
    Geller, MD
    Hering, SV
    Sioutas, C
    AEROSOL SCIENCE AND TECHNOLOGY, 2005, 39 (05) : 419 - 427
  • [9] SINGLE-PARTICLE MOTION AT HIGH SPINS
    STEPHENS, FS
    NUCLEAR PHYSICS A, 1994, 574 (1-2) : C11 - C25
  • [10] Digital gated single-particle counting system, the errors analysis
    Zielinski, M
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (05) : 1069 - 1076