The effect of tone-reducing orthotic devices on soleus muscle reflex excitability while standing in patients with spasticity following stroke

被引:10
作者
Ibuki, Aileen [1 ]
Bach, Timothy [2 ]
Rogers, Douglas [2 ]
Bernhardt, Julie [3 ]
机构
[1] La Trobe Univ, Div Allied Hlth, Natl Ctr Prosthet & Orthot, Bundoora, Vic 3086, Australia
[2] La Trobe Univ, Sch Human Biosci, Bundoora, Vic 3086, Australia
[3] Heidelberg Repatriat Hosp, Natl Stroke Res Inst, Clin Trials Div, Heidelberg, Vic, Australia
关键词
Lower limb orthotics; muscle spasticity; tone-reducing; soleus muscle; stroke; ANKLE-FOOT ORTHOSES; H-REFLEX; HOFFMANN REFLEX; CEREBRAL-PALSY; UPPER-LIMB; STRETCH; CHILDREN; SPLINT; GAIT; INHIBITION;
D O I
10.3109/03093640903476802
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Orthoses are commonly prescribed for the management of spasticity but their neurophysiologic effect on spasticity remains unsubstantiated. The purpose of this study was to investigate the effect of three tone-reducing devices (dynamic foot orthosis, muscle stretch, and orthokinetic compression garment) on soleus muscle reflex excitability while standing in patients with spasticity following stroke. A repeated-measures intervention study was conducted on 13 patients with stroke selected from a sample of convenience. A custom-made dynamic foot orthosis, a range of motion walker to stretch the soleus muscle and class 1 and class 2 orthokinetic compression garments were assessed using the ratio of maximum Hoffmann reflex amplitude to maximum M-response amplitude (Hmax:Mmax) to determine their effect on soleus muscle reflex excitability. Only 10 subjects were able to complete the testing. There were no significant treatment effects for the interventions (F = 1.208, df = 3.232, p = 0.328); however, when analyzed subject-by-subject, two subjects responded to the dynamic foot orthosis and one of those two subjects also responded to the class 1 orthokinetic compression garment. Overall, the results demonstrated that the tone-reducing devices had no significant effect on soleus reflex excitability suggesting that these tone-reducing orthotic devices have no significant neurophysiologic effect on spasticity.</.
引用
收藏
页码:46 / 57
页数:12
相关论文
共 52 条
[1]  
Ali A, 2001, Electromyogr Clin Neurophysiol, V41, P209
[2]  
[Anonymous], BRIT J OCCUPATIONAL, DOI DOI 10.1177/030802260306601005
[3]  
[Anonymous], 1973, HUM REFLEXES PATHOPH, DOI DOI 10.1159/000394143
[4]  
BLAIR E, 1995, DEV MED CHILD NEUROL, V37, P544
[5]  
BLASHY M R, 1959, Am J Occup Ther, V13, P226
[6]   High- or low-technology measurements of energy expenditure in clinical gait analysis? [J].
Boyd, R ;
Fatone, S ;
Rodda, J ;
Olesch, C ;
Starr, R ;
Cullis, E ;
Gallagher, D ;
Carlin, JB ;
Nattrass, GR ;
Graham, K .
DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 1999, 41 (10) :676-682
[7]  
*BRIT STAND I, 2001, 127182001 BS
[8]  
BRONKHORST AJ, 1987, ORTHOTICS PROSTHET, V41, P23
[9]   AUTOGENIC EFFECTS OF STATIC MUSCLE STRETCH IN SPASTIC MAN [J].
BURKE, D ;
ANDREWS, C ;
ASHBY, P .
ARCHIVES OF NEUROLOGY, 1971, 25 (04) :367-&
[10]   Soleus H-reflex gain in healthy elderly and young adults when lying, standing, and balancing [J].
Chalmers, GR ;
Knutzen, KM .
JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2002, 57 (08) :B321-B329