Analysis of combined influence of foulant concentration and flux in ultrafiltration membrane process using response surface methodology

被引:0
作者
Jang, Yongsun [1 ]
Choi, Yongjun [1 ]
Ko, Younghoon
Lee, Sangho [1 ]
Koo, Jaewuk [1 ,2 ]
Park, Youn-Jong [3 ]
机构
[1] Kookmin Univ, Sch Civil & Environm Engn, Seoul 136702, South Korea
[2] Korea Inst Construct Technol, 2311 Daehwa Dong, Goyang Si 411712, Gyeonggi Do, South Korea
[3] SK Engn & Construct, 192-18 Gwanhoon Dong, Seoul, South Korea
关键词
Microfiltration (MF); Ultrafiltration (UF); Fouling; Flux; Response surface methodology (RSM); NATURAL ORGANIC-MATTER; HOLLOW-FIBER ULTRAFILTRATION; WATER-TREATMENT; FOULING CONTROL; FILTRATION; MF; PRETREATMENT; PARTICLES; REMOVAL; MICROFILTRATION;
D O I
10.5004/dwt.2016.005561
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Microfiltration (MF) and ultrafiltration (UF) have been extensively adopted as alternatives to conventional filtration. However, one of the main barriers to widespread use of these technologies is membrane fouling that affects both the quality and the quantity of the product water. Accordingly, the operation conditions for MF/UF should be properly adjusted to minimize fouling. The objective of this study is to analyze combined influence of foulant concentration and flux on fouling propensity of hollow fiber UF membrane through response surface methodology and Central Composite Design. Colloidal silica, kaolin and alginate were used as model foulants, and the concentration of foulant and flux were chosen as the operation parameter. In each case, the fouling rate was determined based on the experimental results. Second-order polynomial model equations were derived to predict the fouling rate as a function of foulant concentration and flux. Finally, operating conditions for a given level of fouling were determined using the model equation and the optimization plot.
引用
收藏
页码:50 / 57
页数:8
相关论文
共 38 条
[1]   A mechanistic model for ultrafiltration membrane fouling by latex [J].
Abdelrasoul, Amira ;
Doan, Huu ;
Lohi, Ali .
JOURNAL OF MEMBRANE SCIENCE, 2013, 433 :88-99
[2]   A review on the applicability of integrated/hybrid membrane processes in water treatment and desalination plants [J].
Ang, Wei Lun ;
Mohammad, Abdul Wahab ;
Hilal, Nidal ;
Leo, Choe Peng .
DESALINATION, 2015, 363 :2-18
[3]   Membrane fouling in ultrafiltration of natural water after pretreatment to different extents [J].
Ao, Lu ;
Liu, Wenjun ;
Zhao, Lin ;
Wang, Xiaomao .
JOURNAL OF ENVIRONMENTAL SCIENCES, 2016, 43 :234-243
[4]   Enzymatic control of alginate fouling of dead-end MF and UF ceramic membranes [J].
Chen, Dong ;
Columbia, Michael .
JOURNAL OF MEMBRANE SCIENCE, 2011, 381 (1-2) :118-125
[5]   Response surface modeling and optimization of copper removal from aqua solutions using polymer assisted ultrafiltration [J].
Cojocaru, Comehu ;
Zakrzewska-Trznadel, Grazyna .
JOURNAL OF MEMBRANE SCIENCE, 2007, 298 (1-2) :56-70
[6]   Ultrafiltration of orange press liquor: Optimization for permeate flux and fouling index by response surface methodology [J].
Figueroa, Rene Andres Ruby ;
Cassano, Alfredo ;
Drioli, Enrico .
SEPARATION AND PURIFICATION TECHNOLOGY, 2011, 80 (01) :1-10
[7]   The effect of coagulation with MF/UF membrane filtration for the removal of virus in drinking water [J].
Fiksdal, Liv ;
Leiknes, TorOve .
JOURNAL OF MEMBRANE SCIENCE, 2006, 279 (1-2) :364-371
[8]   Effects of aeration parameters on effluent quality and membrane fouling in a submerged membrane bioreactor using Box-Behnken response surface methodology [J].
Fu, Hai-Yan ;
Xu, Peng-Cheng ;
Huang, Guo-He ;
Chai, Tian ;
Hou, Ming ;
Gao, Pan-Feng .
DESALINATION, 2012, 302 :33-42
[9]   Comparison of DMF and UF pre-treatments for particulate material and dissolved organic matter removal in SWRO desalination [J].
Guastalli, Andrea R. ;
Xavier Simon, F. ;
Penru, Ywann ;
de Kerchove, Alexis ;
Llorens, Joan ;
Baig, Sylvie .
DESALINATION, 2013, 322 :144-150
[10]   Effect of membrane configuration on bench-scale MF and UF fouling experiments [J].
Howe, Kerry J. ;
Marwah, Ashish ;
Chiu, Kuang-Ping ;
Adham, Samer S. .
WATER RESEARCH, 2007, 41 (17) :3842-3849