Statistical Analysis of Switching Overvoltages and Insulation Coordination For a 500 kV Transmission Line

被引:0
|
作者
Hamza, A. H. [1 ]
Ghania, Samy M. [1 ]
Emam, Ahmed M. [2 ]
Shafy, Ahmed S. [1 ]
机构
[1] Benha Univ, Cairo, Egypt
[2] Cairo Univ, Giza, Egypt
关键词
Switching overvoltages; insulation coordination; transmission lines;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The modern methods of insulation coordination make use of probabilistic concepts and statistical procedures especially for very high voltage systems. This paper presents, a proper approach to calculate the switching surge flashover rate (SSFOR) using Adaptive Neuro Fuzzy Interface System (ANFIS). The switching overvoltages distribution along the power transmission line under different conditions are investigated. The statistical distributions of energization overvoltages for a typical Egyptian 500 kV double-line from High-Dam to Samalut are derived based on the results of 100 energization scenarios by randomly switching using alternate transient program (ATP). The statistical distributions and its key values, such as mean value, standard deviation and 2% statistical overvoltages values have been recorded. The effects of the line length, source strength and shunt reactors for controlling the switching surge overvoltages are demonstrated. The developed ANFIS system is used to estimate the SSFOR for different input parameters for both of the switching overvoltages and the insulation strength distributions with high and comparable accuracy.
引用
收藏
页码:683 / 686
页数:4
相关论文
共 50 条
  • [21] Insulation Coordination Studies on the Future Italian 36 kV Network - Transient Overvoltages
    Buono, Luca
    Di Bona, Franco
    Palone, Francesco
    Papi, Lorenzo
    Spezie, Roberto
    Tresso, Gabriele
    2024 INTERNATIONAL CONFERENCE ON SMART ENERGY SYSTEMS AND TECHNOLOGIES, SEST 2024, 2024,
  • [22] New controlled switching approach for limitation of transmission line switching overvoltages
    Seyedi, Heresh
    Tanhaeidilmaghani, Shahab
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2013, 7 (03) : 218 - 225
  • [23] FULL-SCALE TESTS IN JAPAN ON 500-KV TRANSMISSION LINE INSULATION
    KAWAI, M
    YASUI, M
    KISHIZIMA, I
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1969, PA88 (02): : 133 - +
  • [26] Simulating Calculations of Transient Voltages and Insulation Coordination on 500 kV AC XLPE Submarine Cable Line
    Tian, Shijin
    Liu, Xuezhong
    Liu, Hao
    Wang, Shaohua
    Fu, Dahong
    2017 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND POWER SYSTEMS (ICHVEPS), 2017, : 484 - 487
  • [27] Statistical Analysis of Switching Overvoltages in the Low Voltage Network
    Dolnik, Bystrik
    PROCEEDINGS OF THE 6TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING - ELEKTROENERGETIKA 2011, 2011, : 228 - 230
  • [28] Switching surge test for air insulation design of 765 kV double circuit transmission line
    Shim, JW
    Kim, JB
    Cho, SB
    Kwak, JS
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 1997, : 1175 - 1180
  • [29] SWITCHING OVERVOLTAGES AND RISK OF FLASHOVER ON YUGOSLAV 400 KV TRANSMISSION-LINES
    ZDRAVKOVIC, ZS
    VUKELJA, PI
    IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1992, 139 (02) : 141 - 151
  • [30] Fault analysis and modified measures of 500 kV compact transmission line
    Wang, Li-Ming
    Sun, Bao-Qiang
    Hou, Lei
    Fu, Guan-Jun
    Meng, Xiao-Bo
    Guan, Zhi-Cheng
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (09): : 2108 - 2113