High resolution polarimeter-interferometer system for fast equilibrium dynamics and MHD instability studies on Joint-TEXT tokamak

被引:57
|
作者
Chen, J. [1 ]
Zhuang, G. [1 ]
Li, Q. [1 ]
Liu, Y. [1 ]
Gao, L. [1 ]
Zhou, Y. N. [1 ]
Jian, X. [1 ]
Xiong, C. Y. [1 ]
Wang, Z. J. [1 ]
Brower, D. L. [2 ]
Ding, W. X. [2 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
[2] Univ Calif Los Angeles, Dept Phys & Astron, Los Angeles, CA 90095 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2014年 / 85卷 / 11期
关键词
MAGNETIC-FIELD MEASUREMENTS;
D O I
10.1063/1.4891603
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high-performance Faraday-effect polarimeter-interferometer system has been developed for the J-TEXT tokamak. This system has time response up to 1 mu s, phase resolution < 0.1 degrees and minimum spatial resolution similar to 15 mm. High resolution permits investigation of fast equilibrium dynamics as well as magnetic and density perturbations associated with intrinsic Magneto-Hydro-Dynamic (MHD) instabilities and external coil-induced Resonant Magnetic Perturbations (RMP). The 3-wave technique, in which the line-integrated Faraday angle and electron density are measured simultaneously by three laser beams with specific polarizations and frequency offsets, is used. In order to achieve optimum resolution, three frequency-stabilized HCOOH lasers (694 GHz, > 35 mW per cavity) and sensitive Planar Schottky Diode mixers are used, providing stable intermediate-frequency signals (0.5-3 MHz) with S/N > 50. The collinear R- and L-wave probe beams, which propagate through the plasma poloidal cross section (a = 0.25-0.27 m) vertically, are expanded using parabolic mirrors to cover the entire plasma column. Sources of systematic errors, e.g., stemming from mechanical vibration, beam non-collinearity, and beam polarization distortion are individually examined and minimized to ensure measurement accuracy. Simultaneous density and Faraday measurements have been successfully achieved for 14 chords. Based on measurements, temporal evolution of safety factor profile, current density profile, and electron density profile are resolved. Core magnetic and density perturbations associated with MHD tearing instabilities are clearly detected. Effects of non-axisymmetric 3D RMP in ohmically heated plasmas are directly observed by polarimetry for the first time. (C) 2014 AIP Publishing LLC.
引用
收藏
页数:8
相关论文
共 9 条
  • [1] Upgrade of far infrared three-wave polarimeter-interferometer system on Joint-TEXT
    Yang, Qinglong
    Gao, Li
    Shi, Peng
    Zhou, Yinan
    Wang, Yuhan
    Zhou, Chengxi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (05):
  • [2] Fast Data Processing of a Polarimeter-Interferometer System on J-TEXT
    刘煜锴
    高丽
    刘海庆
    杨曜
    高翔
    JTEXT Team
    Plasma Science and Technology, 2016, 18 (12) : 1143 - 1147
  • [3] Fast Data Processing of a Polarimeter-Interferometer System on J-TEXT
    Liu Yukai
    Gao Li
    Liu Haiqing
    Yang Yao
    Gao Xiang
    PLASMA SCIENCE & TECHNOLOGY, 2016, 18 (12) : 1143 - 1147
  • [4] Fast Data Processing of a Polarimeter-Interferometer System on J-TEXT
    刘煜锴
    高丽
    刘海庆
    杨曜
    高翔
    J-TEXT Team
    Plasma Science and Technology, 2016, (12) : 1143 - 1147
  • [5] A real-time laser feedback control method for the three-wave laser source used in the polarimeter-interferometer diagnostic on Joint-TEXT tokamak
    Xiong, C. Y.
    Chen, J.
    Li, Q.
    Liu, Y.
    Gao, L.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (12):
  • [6] First results of the J-TEXT high-resolution 3-wave polarimeter-interferometer system
    Zhuang, G.
    Chen, J.
    Li, Q.
    Gao, L.
    Wang, Z. J.
    Liu, Y.
    Chen, W.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [7] Design of far-infrared three-wave polarimeter-interferometer system for the J-TEXT tokamak
    Chen, J.
    Gao, L.
    Zhuang, G.
    Wang, Z. J.
    Gentle, K. W.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [8] First results from the J-TEXT high-resolution three-wave polarimeter-interferometer
    Chen, J.
    Zhuang, G.
    Wang, Z. J.
    Gao, L.
    Li, Q.
    Chen, W.
    Brower, D. L.
    Ding, W. X.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [9] Fizeau interferometer system for fast high resolution studies of spectral line shapes
    Novak, O.
    Falconer, I. S.
    Sangines, R.
    Lattemann, M.
    Tarrant, R. N.
    McKenzie, D. R.
    Bilek, M. M. M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (02):