PM2.5 and ultrafine particulate matter emissions from natural gas-fired turbine for power generation

被引:24
作者
Brewer, Eli [1 ]
Li, Yang [1 ]
Finken, Bob [2 ]
Quartucy, Greg [3 ]
Muzio, Lawrence [3 ]
Baez, Al [4 ]
Garibay, Mike [4 ]
Jung, Heejung S. [1 ]
机构
[1] Univ Calif Riverside, Dept Mech Engn, Riverside, CA 92521 USA
[2] Delta Air Qual Serv Inc, 1845 North Case St, Orange, CA 92865 USA
[3] Fossil Energy Res Corp FERCo, 23342-C South Pointe Dr, Laguna Hills, CA 92653 USA
[4] SCAQMD, 21865 Copley Dr, Diamond Bar, CA 91765 USA
关键词
Atmospheric nanoparticle; Method; 201A; 5.1; Emission; PARTICLES; AIRCRAFT; DENSITY;
D O I
10.1016/j.atmosenv.2015.11.048
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The generation of electricity from natural gas-fired turbines has increased more than 200% since 2003. In 2007 the South Coast Air Quality Management District (SCAQMD) funded a project to identify control strategies and technologies for PM2.5 and ultrafine emissions from natural gas-fired turbine power plants and test at pilot scale advanced PM2.5 technologies to reduce emissions from these gas turbine-based power plants. This prompted a study of the exhaust from new facilities to better understand air pollution in California. To characterize the emissions from new natural gas turbines, a series of tests were performed on a GE LMS100 gas turbine located at the Walnut Creek Energy Park in August 2013. These tests included particulate matter less than 2.5 mu m in diameter (PM2.5) and wet chemical tests for SO2/SO3 and NH3, as well as ultrafine (less than 100 nm in diameter) particulate matter measurements. After turbine exhaust was diluted sevenfold with filtered air, particle concentrations in the 10-300 nm size range were approximately two orders of magnitude higher than those in the ambient air and those in the 2-3 nm size range were up to four orders of magnitude higher. This study also found that ammonia emissions were higher than expected, but in compliance with permit conditions. This was possibly due to an ammonia imbalance entering the catalyst, some flue gas bypassing the catalyst, or not enough catalyst volume. SO3 accounted for an average of 23% of the total sulfur oxides emissions measured. While some of the SO3 is formed in the combustion process, it is likely that the majority formed as the SO2 in the combustion products passed across the oxidizing CO catalyst and SCR catalyst. The 100 MW turbine sampled in this study emitted particle loadings of 3.63E-04 lb/MMEtu based on Methods 5.1/201A and 1.07E-04 lb/MMBtu based on SMPS method, which are similar to those previously measured from turbines in the SCAQMD area (FERCo et al., 2014), however, the turbine exhaust contained orders of magnitude higher particles than ambient air. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:141 / 149
页数:9
相关论文
共 29 条
  • [1] Network Analysis of Fine Particulate Matter (PM2.5) Emissions in China
    Yan, Shaomin
    Wu, Guang
    SCIENTIFIC REPORTS, 2016, 6
  • [2] Assessing the Methane Emissions from Natural Gas-Fired Power Plants and Oil Refineries
    Lavoie, Tegan N.
    Shepson, Paul B.
    Gore, Chloe A.
    Stirm, Brian H.
    Kaeser, Robert
    Wulle, Bernard
    Lyon, David
    Rudek, Joseph
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2017, 51 (06) : 3373 - 3381
  • [3] Emission characteristics of PM2.5 and components of condensable particulate matter from coal-fired industrial plants
    Wu, Yujia
    Xu, Zhenyao
    Liu, Siqi
    Tang, Minghui
    Lu, Shengyong
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 796
  • [4] Emission of Particulate Matter 2.5 (PM2.5) from Sewage Sludge Incinerators in Japan
    Shiota, Kenji
    Takaoka, Masaki
    Yamaguchi, Shuji
    Oshita, Kazuyuki
    DRYING TECHNOLOGY, 2015, 33 (11) : 1286 - 1294
  • [5] Particulate Matter Emissions from a Coal-Fired Power Plant
    Lu, Ping
    Wu, Jiang
    Pan, Wei-Ping
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [6] Cluster analysis of fine particulate matter (PM2.5) emissions and its bioreactivity in the vicinity of a petrochemical complex
    Chuang, Hsiao-Chi
    Shie, Ruei-Hao
    Chio, Chia-Pin
    Yuan, Tzu-Hsuen
    Lee, Jui-Huan
    Chan, Chang-Chuan
    ENVIRONMENTAL POLLUTION, 2018, 236 : 591 - 597
  • [7] Particulate characteristics data for the management of PM2.5 emissions from stationary combustion sources
    Lee, S. Win
    Herage, T.
    He, I.
    Young, B.
    POWDER TECHNOLOGY, 2008, 180 (1-2) : 145 - 150
  • [8] Discussion on the Emission Control of PM2.5 from Coal-fired Power Plants
    Pan, Xueqin
    Zheng, Jinlang
    Wang, Jianchun
    Jin, Yujian
    Jiang, Minmin
    ENERGY, ENVIRONMENT AND ENGINEERING, 2012, 4 : 26 - 28
  • [9] Role of metals in free radical generation and genotoxicity induced by airborne particulate matter (PM2.5) from Pune (India)
    Yadav, Suman
    Jan, Rohi
    Roy, Ritwika
    Satsangi, P. Gursumeeran
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2016, 23 (23) : 23854 - 23866
  • [10] In vivo and in vitro inflammatory responses to fine particulate matter (PM2.5) from China and California
    Yuan, Wanjun
    Fulgar, Ciara C.
    Sun, Xiaolin
    Vogel, Christoph F. A.
    Wu, Ching-Wen
    Zhang, Qi
    Bein, Keith J.
    Young, Dominique E.
    Li, Wei
    Wei, Haiying
    Pinkerto, Kent E.
    TOXICOLOGY LETTERS, 2020, 328 : 52 - 60