Keratoconus Screening Indices and Their Diagnostic Ability to Distinguish Normal From Ectatic Corneas

被引:120
作者
Shetty, Rohit [1 ]
Rao, Harsha [1 ]
Khamar, Pooja [1 ]
Sainani, Kanchan [1 ]
Vunnava, Krishnapoojita [1 ]
Jayadev, Chaitra [1 ]
Kaweri, Luci [1 ]
机构
[1] Narayana Nethralaya Eye Inst, Bangalore, Karnataka, India
关键词
TOPOGRAPHY; PENTACAM;
D O I
10.1016/j.ajo.2017.06.031
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the diagnostic ability of 3 Scheimpflug devices in differentiating normal from ectatic corneas. DESIGN: Comparison of diagnostic instrument accuracy. METHODS: This study included 42 normal, 37 subclinical keratoconic, and 51 keratoconic eyes seen in a tertiary eye care institute. Keratoconus screening indices were evaluated using the Pentacam (Oculus, Wetzlar, Germany), Galilei (Ziemer, Biel, Switzerland), and Sirius (Costruzione Strumenti Oftalmici, Florence, Italy). Sensitivity, specificity, and area under receiver operating characteristic curve (AUC) were calculated. RESULTS: Highest sensitivity (100%) to diagnose keratoconus was seen for 6 parameters on Pentacam and 1 on Galilei. None of the indices in Sirius reached 100% sensitivity. For subclinical keratoconus, the highest sensitivity (100%) was seen for 2 parameters on Pentacam but for none of them on Galilei and Sirius. All parameters were strong enough to differentiate.keratoconus (AUC > 0.9). On comparing the best parameters of all 3 machines, the AUC of the Belin/Ambrosio enhanced ectasia total derivation (BAD-D) and the inferior superior value (ISV) of Pentacam were statistically similar to that of the keratoconus prediction index (KPI) and keratoconus probability (Kprob) of Galilei (P = .27) and 4.5 mm root mean square per unit area (RMS/A) back of Sirius (P = .55). When differentiating subclinical from normal corneas, BAD-D was similar to the surface regularity index (SRI) of Galilei (P = .78) but was significantly greater than the 8 mm RMS/A back of Sirius (P = .002). CONCLUSION: Keratoconus indices measured by all 3 machines can effectively differentiate keratoconus from normal corneas. However, new cutoff values might be needed to differentiate subclinical from normal corneas. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 17 条
[1]   Scheimpflug imaging for keratoconus and ectatic disease [J].
Belin, Michael W. ;
Ambrosio, Renato, Jr. .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (08) :401-406
[2]   Corneal topography in keratoconus: state of the art [J].
Cavas-Martinez, F. ;
De la Cruz Sanchez, E. ;
Nieto Martinez, J. ;
Fernandez Canavate, F. J. ;
Fernandez-Pacheco, D. G. .
EYE AND VISION, 2016, 3
[3]   Sensitivity and specificity of posterior corneal elevation measured by Pentacam in discriminating keratoconus/subclinical keratoconus [J].
de Sanctis, Ugo ;
Loiacono, Carlotta ;
Richiardi, Lorenzo ;
Turco, Davide ;
Mutani, Bernardo ;
Grignolo, Federico M. .
OPHTHALMOLOGY, 2008, 115 (09) :1534-1539
[4]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[5]  
Feizi Sepehr, 2016, J Ophthalmic Vis Res, V11, P8, DOI 10.4103/2008-322X.180707
[6]   Comparison of Two Different Scheimpflug Devices in the Detection of Keratoconus, Regular Astigmatism, and Healthy Corneas [J].
Finis, David ;
Ralla, Bernhard ;
Karbe, Maria ;
Borrelli, Maria ;
Schrader, Stefan ;
Geerling, Gerd .
JOURNAL OF OPHTHALMOLOGY, 2015, 2015
[7]  
Florkowski Christopher M, 2008, Clin Biochem Rev, V29 Suppl 1, pS83
[8]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[9]   Pentacam top indices for diagnosing subclinical and definite keratoconus [J].
Hashemi, Hassan ;
Beiranvand, Asghar ;
Yekta, Abbasali ;
Maleki, Azam ;
Yazdani, Negareh ;
Khabazkhoob, Mehdi .
JOURNAL OF CURRENT OPHTHALMOLOGY, 2016, 28 (01) :21-26
[10]  
MAEDA N, 1994, INVEST OPHTH VIS SCI, V35, P2749