Self-Centering Frictional Damper (SCFD)

被引:31
作者
Westenenk, B. [1 ,2 ]
Edwards, J. J. [1 ,2 ]
de la Llera, J. C. [1 ]
Junemann, R. [1 ,2 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Struct & Geotech Engn, Vicuna Mackenna 4860, Santiago, Chile
[2] CONICYT FONDAP 15110017, Natl Res Ctr Integrated Management Nat Disaaters, Vicuna Mackenna 4860, Santiago, Chile
关键词
Frictional damper; Self-centering behavior; Seismic protection; Experimental validation; FEM design; WEAR PROPERTIES; BEHAVIOR; COMPOSITE; SYSTEM; BRONZE;
D O I
10.1016/j.engstruct.2019.109425
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes the behavior and design of a new self-centering frictional damper. This device is based on conic friction surfaces that lead to a flag-shaped hysteretic behavior. Its self-centering property and different possible configurations make it a very versatile device to be used in seismic applications of high-rise buildings subject to earthquakes. A simple mathematical model is presented first to describe the cyclic behavior of the device. Then, important variables related with the geometry and materials used in the device are analyzed to better understand their influence on the hysteretic behavior of the damper and optimize its design. Different friction materials, rubber samples, and coil springs are tested in the laboratory for the design of a proof-of-concept prototype. To test the theoretical model, the 115 kN large-scale damper was manufactured and dynamically tested in the laboratory obtaining excellent agreement between the theoretical and experimental results. Finally, a detailed finite element model was generated to study the local stress concentrations of the different components of the device as well as compare the hysteretic behavior for different possible configurations using metallic and rubber springs.
引用
收藏
页数:19
相关论文
共 32 条
[1]  
AIKEN I, 1996, LOS ANG COUNT SEAOSC
[2]  
Aiken I.D., 1993, EARTHQ SPECTRA, V9
[3]  
[Anonymous], ANSYS AC RES REL 12
[4]   Seismic analysis of structures connected with friction dampers [J].
Bhaskararao, AV ;
Jangid, RS .
ENGINEERING STRUCTURES, 2006, 28 (05) :690-703
[5]  
Boyce M., 2000, Rubber Chemistry and Technology, V73, P894
[6]   Vibration tests of precompressed rubber springs and a flag-shaped smart damper [J].
Choi, Eunsoo ;
Youn, Heejung ;
Park, Kyoungsoo ;
Jeon, Jong-Su .
ENGINEERING STRUCTURES, 2017, 132 :372-382
[7]   Experimental evaluation of large-scale dual-core self-centering braces and sandwiched buckling-restrained braces [J].
Chou, Chung-Che ;
Chung, Ping-Ting ;
Cheng, Yu-Tsen .
ENGINEERING STRUCTURES, 2016, 116 :12-25
[8]   Self-centering energy dissipative bracing system for the seismic resistance of structures: Development and validation [J].
Christopoulos, C. ;
Tremblay, R. ;
Kim, H. -J. ;
Lacerte, M. .
JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (01) :96-107
[9]   Design, Testing, and Detailed Component Modeling of a High-Capacity Self-Centering Energy-Dissipative Brace [J].
Erochko, Jeffrey ;
Christopoulos, Constantin ;
Tremblay, Robert .
JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (08)
[10]   An experimental study on the effects of manufacturing parameters on the tribological properties of brake lining materials [J].
Ertan, Rukiye ;
Yavuz, Nurettin .
WEAR, 2010, 268 (11-12) :1524-1532