New amperometric glucose biosensor based on cross-linking of glucose oxidase on silica gel/multiwalled carbon nanotubes/polyacrylonitrile nanocomposite film

被引:61
作者
Nenkova, Ruska [1 ]
Ivanova, Danka [1 ]
Vladimirova, Janina [1 ]
Godjevargova, Tzonka [1 ]
机构
[1] Univ Bourgas, Dept Biotechnol, Burgas 8010, Bulgaria
关键词
Biosensor; Glucose oxidase; Polyacrylonitrile; Silica gel; Multiwalled carbon nanotubes; ACRYLONITRILE COPOLYMER MEMBRANES; SOL-GEL PROCESS; COMPOSITE FILM; MICROPOROUS MEMBRANES; MODIFIED ELECTRODES; IMMOBILIZATION; NANOTUBES; LAYER; UREASE; MATRIX;
D O I
10.1016/j.snb.2010.05.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new amperometric glucose biosensor was formed by cross-linking glucose oxidase (GOD) on nanocomposite material prepared by entrapping silica gel (SG) and multiwalled carbon nanotubes (MWNTs) in polyacrylonitrile (PAN) film. The optimal conditions for nanocomposite matrix preparation were studied. The influence of the amount of silica gel, MWNTs and enzyme concentration on the biosensor performance was examined. Silica gel/MWNT/PAN/GOD has linear range for the detection of glucose from 5 mu M to 2 mM (a correlation coefficient of 0.999) with 16 s response time. The sensitivity of the biosensor was found to be 16.5 mu A/mM. Moreover, its experimental detection limit is 1 mu M (S/N =3) and the apparent Michaelis-Menten constant was calculated to be 13.9 mM. The ascorbic acid interference and long-term stability of the biosensor are also assessed. All the results show that Silica gel/MWNT/PAN can provide a promising material for the biosensor designs for glucose detection. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 39 条
[21]   APPLICATION OF MICROPOROUS MEMBRANES TO CHEMI-LUMINESCENCE ANALYSIS [J].
NAU, V ;
NIEMAN, TA .
ANALYTICAL CHEMISTRY, 1979, 51 (03) :424-428
[22]  
Prodromidis MI, 2002, ELECTROANAL, V14, P241
[23]   Surfactant-modified poly(vinyl chloride) membranes as biocompatible interfaces for amperometric enzyme electrodes [J].
Reddy, SM ;
Vadgama, PM .
ANALYTICA CHIMICA ACTA, 1997, 350 (1-2) :77-89
[24]   Chemiluminescent biosensors based on porous supports with immobilized peroxidase [J].
Rubtsova, MY ;
Kovba, GV ;
Egorov, AM .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (01) :75-85
[25]   Glucose biosensor prepared by glucose oxidase encapsulated sol-gel and carbon-nanotube-modified basal plane pyrolytic graphite electrode [J].
Salimi, A ;
Compton, RG ;
Hallaj, R .
ANALYTICAL BIOCHEMISTRY, 2004, 333 (01) :49-56
[26]   Inert metal-modified, composite ceramic-carbon, amperometric biosensors: Renewable, controlled reactive layer [J].
Sampath, S ;
Lev, O .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2015-2021
[27]   Amperometric glucose biosensor based on in situ electropolymerized polyaniline/poly(acrylonitrile-co-acrylic acid) composite film [J].
Shan, Dan ;
Wang, Shanxia ;
He, Yuanyuan ;
Xue, Huaiguo .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2008, 28 (02) :213-217
[28]   A porous poly(acrylonitrile-co-acrylic acid) film-based glucose biosensor constructed by electrochemical entrapment [J].
Shan, Dan ;
He, Yuanyuan ;
Wang, Shanxia ;
Xue, Huaiguo ;
Zheng, Hao .
ANALYTICAL BIOCHEMISTRY, 2006, 356 (02) :215-221
[29]   Cyclic voltammetry on electrode surfaces covered with porous layers: An analysis of electron transfer kinetics at single-walled carbon nanotube modified electrodes [J].
Streeter, Ian ;
Wildgoose, Gregory G. ;
Shao, Lidong ;
Compton, Richard G. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 133 (02) :462-466
[30]   Amperometric glucose biosensor based on gold-deposited polyvinylferrocene film on Pt electrode [J].
Sulak, MT ;
Gökdogan, Ö ;
Gülce, A ;
Gülce, H .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (09) :1719-1726