Reliability of nocturnal blood pressure dipping

被引:33
作者
Dimsdale, JE
von Känel, R
Profant, J
Nelesen, R
Ancoli-Israel, S
Ziegler, M
机构
[1] Univ Calif San Diego, Dept Psychiat, La Jolla, CA 92093 USA
[2] UCSD, SDSU, Joint Doctoral Program Clin Psychol, San Diego, CA USA
[3] UCSD, Dept Med, San Diego, CA USA
[4] Vet Affairs San Diego Healthcare Syst, San Diego, CA USA
关键词
blood pressure; dipping; ambulatory blood pressure monitoring; sleep;
D O I
10.1097/00126097-200008000-00004
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background Increasing evidence documents the fact that individuals whose blood pressure drops or 'dips' relatively little at night have a higher risk of numerous cardiovascular illnesses. Objective To examine the reliability of various measures of nocturnal blood pressure dipping. Methods This study examined 17 individuals with ambulatory blood pressure monitoring on three 24 h recordings while they pursued a schedule similar to that of in-patients on a clinical research unit. Nocturnal dipping of blood pressure was scored three ways: as the drop in blood pressure between 10 p.m. and 6 a.m. ('clocktime'), as the drop in blood pressure tailored to each individual's reported bedtime ('bedtime'), and as the drop in blood pressure accompanying polysomnographically verified sleep ('sleeptime'). Results Adequate reliability was obtained for all three measures of dipping. There was, in general, a significant correlation across testing occasions (P < 0.05). The correlation coefficient ranged from 0.5 to 0.8, depending on which criterion of dipping was selected and whether the endpoint was systolic blood pressure, diastolic blood pressure, or mean arterial blood pressure. Conclusions The reliability of systolic blood pressure dipping was somewhat lower than that of diastolic or mean arterial blood pressure dipping. Dipping appears to be a reliable construct. While no one definition of dipping was demonstrably better than another, the most sensible definition of dipping would allow some adjustment for defining 'night' on the basis of each individual's idiosyncratic bed time. (C) 2000 Lippincott Williams & Wilkins.
引用
收藏
页码:217 / 221
页数:5
相关论文
共 33 条
[1]   Marital cohesion and ambulatory blood pressure in early hypertension [J].
Baker, B ;
Helmers, K ;
O'Kelly, B ;
Sakinofsky, I ;
Abelsohn, A ;
Tobe, S .
AMERICAN JOURNAL OF HYPERTENSION, 1999, 12 (02) :227-230
[2]  
Cerasola G., 1994, American Journal of Hypertension, V7, p148A
[3]  
Chamontin, 1996, Blood Press Monit, V1, P329
[4]   TEST-RETEST RELIABILITY OF 24-HOUR AMBULATORY BLOOD PRESSURES [J].
CORNISH, PJ ;
BLANCHARD, EB ;
JACCARD, J .
BIOFEEDBACK AND SELF-REGULATION, 1995, 20 (02) :137-154
[5]   How reliable is nighttime blood pressure dipping? [J].
Dimsdale, JE ;
Heeren, MM .
AMERICAN JOURNAL OF HYPERTENSION, 1998, 11 (05) :606-609
[6]   Effect of continuous positive airway pressure on blood pressure - A placebo trial [J].
Dimsdale, JE ;
Loredo, JS ;
Profant, J .
HYPERTENSION, 2000, 35 (01) :144-147
[7]   Does it matter whether ambulatory blood pressure is recorded during a work day or a non-work day? [J].
Enstrom, I ;
Pennert, K .
JOURNAL OF HYPERTENSION, 1996, 14 (05) :565-569
[8]  
Fagard, 1997, Blood Press Monit, V2, P315
[9]   Prediction of the actual awake and asleep blood pressures by various methods of 24 h pressure analysis [J].
Fagard, R ;
Brguljan, J ;
Thijs, L ;
Staessen, J .
JOURNAL OF HYPERTENSION, 1996, 14 (05) :557-563
[10]  
FILHO AJP, 1995, AM J HYPERTENS, V8, P676