An experimental study of a photovoltaic thermal air collector (PVTAC): A comparison of a flat and the wavy collector

被引:52
作者
Jha, Prabhakar [1 ]
Das, Biplab [1 ,2 ]
Gupta, Rajat [3 ]
机构
[1] Natl Inst Technol Silchar, Dept Mech Engn, Silchar 788010, Assam, India
[2] Ulster Univ, Ctr Sustainable Technol, Coleraine BT37 0QB, Londonderry, North Ireland
[3] Natl Inst Technol Mizoram, Dept Mech Engn, Aizawl 796012, India
关键词
PVTAC; Flat plate; Wavy plate; Mass flow rate; Exergy; Thermal efficiency; PV/T SOLAR COLLECTORS; PERFORMANCE EVALUATION; EXERGY ANALYSIS; ELECTRICAL MODEL; SYSTEM; ENERGY; TECHNOLOGIES; IMPROVEMENT; SIMULATION;
D O I
10.1016/j.applthermaleng.2019.114344
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work, a comparative experimental energy and exergy analysis of photovoltaic thermal air collector (PVTAC) with a flat plate (model-I) and wavy plate (model-II) as a solar thermal collector is performed. Integration wavy plate is expected to enhance the rate of redistribution of fluid flow and thus to enhance the heat extraction rate. Thereby helps to control the temperature of the PV module during higher solar insolation, during which the conversion efficiency of the PV module tends to decrease. The experimental investigation of performance enhancement of PVTAC is carried out at different values of airflow rates of 0.0047-0.0165 kg/s. Results indicate that the highest overall thermal energy and overall thermal exergy of the PVTAC system are obtained during noontime. Comparative analysis indicates, at noon, model-II provides a higher yield of thermal energy, exergy, and net electrical energy by 16%, 27.4%, and 1.2% than that of model-I. Presence of the wavy plate increases the magnitude pressure drop for model-II than that of model-I. Despite meeting the requirement of higher pumping power, model-II provides 8.4% and 1.3% higher overall thermal efficiency and overall exergy efficiency than that of the model-I.
引用
收藏
页数:13
相关论文
共 53 条
[1]   Experimental Study on Thermal Performance of a Novel Solar Air Collector Having Conical Springs on Absorber Plate [J].
Abuska, Mesut ;
Akgul, Mehmet Bahattin .
ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2016, 41 (11) :4509-4516
[2]   Exergoeconomic analysis of glazed hybrid photovoltaic thermal module air collector [J].
Agrawal, Sanjay ;
Tiwari, G. N. .
SOLAR ENERGY, 2012, 86 (09) :2826-2838
[3]   Energy and exergy analysis of hybrid micro-channel photovoltaic thermal module [J].
Agrawal, Sanjay ;
Tiwari, G. N. .
SOLAR ENERGY, 2011, 85 (02) :356-370
[4]   Air cooling low concentrated photovoltaic/thermal (LCPV/T) solar collector to approach uniform temperature distribution on the PV plate [J].
Amanlou, Yasaman ;
Hashjin, Teymour Tavakoli ;
Ghobadian, Barat ;
Najafi, G. .
APPLIED THERMAL ENGINEERING, 2018, 141 :413-421
[5]   Energy and exergy analysis of different solar air collector systems with forced convection [J].
Bahrehmand, D. ;
Ameri, M. ;
Gholampour, M. .
RENEWABLE ENERGY, 2015, 83 :1119-1130
[6]  
Bosonac M., 2003, 28 EEP, P1713
[7]   Photovoltaic thermal (PV/T) collectors: A review [J].
Charalambous, P. G. ;
Maidment, G. G. ;
Kalogirou, S. A. ;
Yiakoumetti, K. .
APPLIED THERMAL ENGINEERING, 2007, 27 (2-3) :275-286
[8]   Energy and exergy analysis of photovoltaic-thermal collector with and without glass cover [J].
Chow, T. T. ;
Pei, G. ;
Fong, K. F. ;
Lin, Z. ;
Chan, A. L. S. ;
Ji, J. .
APPLIED ENERGY, 2009, 86 (03) :310-316
[9]   Combined Energy and Exergy Analysis of a Nonisothermal Fin Array With Non-Boussinesq Variable Property Fluid [J].
Das, Biplab ;
Giri, Asis .
JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2016, 8 (03)
[10]   Second law analysis of an array of vertical plate-finned heat sink undergoing mixed convection [J].
Das, Biplab ;
Giri, Asis .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2014, 56 :42-49