The relationship between cortical auditory evoked potentials (CAEPs) and speech perception in children with Nurotron® cochlear implants during four years of follow-up

被引:10
作者
Guo, Qianqian [1 ,2 ]
Li, Yuling [1 ,2 ]
Fu, Xinxing [1 ,2 ]
Liu, Hui [1 ,2 ]
Chen, Jing [1 ,2 ]
Meng, Chao [1 ,2 ]
Long, Mo [3 ]
Chen, Xueqing [1 ,2 ]
机构
[1] Capital Med Univ, BeijingTongren Hosp, Beijing 100730, Peoples R China
[2] Capital Med Univ, Beijing Inst Otolaryngol, Key Lab Otolaryngol Head & Neck Surg, Minist Educ, Beijing 100730, Peoples R China
[3] China Rehabil Res Ctr Deaf Children, A8 Huixinli, Beijing 100029, Peoples R China
关键词
Cortical auditory evoked potentials; Cochlear implants; Children; Speech perception; SENSORINEURAL HEARING-LOSS; EVENT-RELATED POTENTIALS; VISUAL DETECTION; USERS; PERFORMANCE; NEUROPATHY; RESPONSES; INFANTS;
D O I
10.1016/j.ijporl.2016.03.035
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective: The purpose of the current study was to evaluate the relationship between the presence or absence of cortical auditory evoked potentials (CAEPs) to speech stimuli and the performance of speech perception in Chinese pediatric recipients of the Nurotron (R) cochlear implant (CI).We also wanted to determine how the CAEPs might be used as an indicator for predicting early speech perception and could provide objective evidence for clinical applications of CAEPs. Methods: 23 pediatric unilateral CI recipients participated in this study. 15 males 8 females, and their ages at implantation ranged from 13 to 68 months, with a mean age of 36 months. CAEPs and Mandarin Early Speech Perception (MESP) tests were used to evaluate the audibility and speech perception of these CI users. The tests were administered at the first, second, third, and fourth year after the CI surgery. Results: All the subjects demonstrated improvements in detection of speech sounds with Cl. The percentages of participants who could detect all three stimuli were 26% (6/23) at first year, to 100% (23/23) at the fourth year post-implantation. The percentages of participants who passed the Category 6 of MESP were from 9% (2/23) at first year, to 91% (21/23) at the fourth year post-implantation. Significant correlations (p < 0.05) were found between CAEP scores and MESP at the first, second, third year after the CI surgery. The multiple regression equation for prediction of MESP categories from CAEP scores and hearing ages was MESP = 1.088 + (0.504 x CAEP score) + (0.964 x hearing ages) (F = 72.919,p < 0.001, R-2 = 0.621). Conclusion: The results of this study suggested that aided cortical assessment was a useful tool to evaluate the outcomes of cochlear implantation. Cortical outcomes had a significant positive relationship with the MESP, which predicted the early speech perception of CI recipients. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:170 / 177
页数:8
相关论文
共 20 条
  • [1] Correlation between Auditory Spectral Resolution and Speech Perception in Children with Cochlear Implants
    Jeddi, Zahra
    Lotfi, Younes
    Moossavi, Abdollah
    Bakhshi, Enayatollah
    Hashemi, Seyed Basir
    IRANIAN JOURNAL OF MEDICAL SCIENCES, 2019, 44 (05) : 382 - 389
  • [2] Correlation between cortical auditory evoked potential and auditory speech performance in children with cochlear implants
    Wang, Xuetong
    Lin, Zhihan
    Guo, Ying
    Liu, Yidi
    Zhou, Xin
    Bai, Jie
    Liu, Haihong
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2023, 172
  • [3] Maturation of cortical auditory evoked potentials (CAEPs) to speech recorded from frontocentral and temporal sites: Three months to eight years of age
    Shafer, Valerie L.
    Yu, Yan H.
    Wagner, Monica
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2015, 95 (02) : 77 - 93
  • [4] Assessing the applications of cortical auditory evoked potentials as a biomarker in children with cochlear implants
    Mostafa I.Z.
    Shabana M.I.
    El Shennawy A.M.
    Weheiba H.M.
    The Egyptian Journal of Otolaryngology, 2013, 29 (4) : 263 - 268
  • [5] The relationship between obligatory cortical auditory evoked potentials (CAEPs) and functional measures in young infants
    Golding, Maryanne
    Pearce, Wendy
    Seymour, John
    Cooper, Alison
    Ching, Teresa
    Dillon, Harvey
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2007, 18 (02) : 117 - 125
  • [6] Speech perception and cortical auditory evoked potentials in cochlear implant users with auditory neuropathy spectrum disorders
    Alvarenga, Katia F.
    Amorim, Raquel Beltrao
    Agostinho-Pesse, Raquel Sampaio
    Costa, Orozimbo Alves
    Nascimento, Leandra Tabanez
    Bevilacqua, Maria Cecilia
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2012, 76 (09) : 1332 - 1338
  • [7] Cortical auditory evoked potentials (P1 latency) in children with cochlear implants in relation to clinical language tests
    Franlund, Karin
    Lindehammar, Hans
    Maki-Torkko, Elina
    Hergils, Leif
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2024, 63 (10) : 802 - 808
  • [8] The family oriented musical training for children with cochlear implants: Speech and musical perception results of two year follow-up
    Yucel, Esra
    Sennaroglu, Gonca
    Belgin, Erol
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2009, 73 (07) : 1043 - 1052
  • [9] Effects of Sequential Bilateral Cochlear Implantation in Children: Evidence from Speech-Evoked Cortical Potentials and Tests of Speech Perception
    Vicente, Leticia Cristina
    Polonenko, Melissa Jane
    Gordon, Karen Ann
    Silva, Leandra Tabanez do Nascimento
    Costa, Orozimbo Alves
    Alvarenga, Katia Freitas
    AUDIOLOGY AND NEUROTOLOGY, 2022, 27 (04) : 282 - 296
  • [10] Cortical auditory evoked potentials in cochlear implant listeners via single electrode stimulation in relation to speech perception
    Liebscher, Tim
    Alberter, Katrin
    Hoppe, Ulrich
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2018, 57 (12) : 933 - 940