The Utility of a Wireless Implantable Hemodynamic Monitoring System in Patients Requiring Mechanical Circulatory Support

被引:27
作者
Feldman, David S. [1 ,4 ]
Moazami, Nader [2 ]
Adamson, Philip B. [3 ]
Vierecke, Juliane [4 ]
Raval, Nir [5 ]
Shreenivas, Satya [1 ]
Cabuay, Barry M. [6 ]
Jimenez, Javier [7 ]
Abraham, William T. [8 ]
O'Connell, John B. [3 ]
Naka, Yoshifumi [9 ]
机构
[1] Univ Cincinnati, Med Ctr, Div Cardiovasc Med, Cincinnati, OH USA
[2] Cleveland Clin Fdn, Cardiothorac Surg, 9500 Euclid Ave, Cleveland, OH 44195 USA
[3] St Jude Med, Sect Adv Med Therapies, St Paul, MN USA
[4] Univ Bern, Div Cardiol, Bern, Switzerland
[5] Florida Hosp Transplant Inst, Orlando, FL USA
[6] Minneapolis Heart Inst, Dept Cardiol, Minneapolis, MN USA
[7] South Miami Hosp, Div Cardiol, South Miami, FL USA
[8] Ohio State Univ, Med Ctr, Div Cardiovasc Med, Columbus, OH 43210 USA
[9] Columbia Univ, Med Ctr, Div Cardiothorac Surg, New York, NY USA
关键词
hemodynamic monitoring; mechanical circulatory support; left ventricular assist device; heart failure; pulmonary wedge pressure; heart transplantation; PULMONARY-ARTERY PRESSURE; ADVANCED HEART-FAILURE; INTERMACS ANNUAL-REPORT; DEVICE; EFFICACY; THERAPY; TRIAL;
D O I
10.1097/MAT.0000000000000670
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Proper timing of left ventricular assist device (LVAD) implantation in advanced heart failure patients is not well established and is an area of intense interest. In addition, optimizing LVAD performance after implantation remains difficult and represents a significant clinical need. Implantable hemodynamic monitoring systems may provide physicians with the physiologic information necessary to improve the timing of LVAD implantation as well as LVAD performance when compared with current methods. The CardioMEMS Heart sensor Allows for Monitoirng of Pressures to Improve Outcomes in NYHA Class III heart failure patients (CHAMPION) Trial enrolled 550 previously hospitalized patients with New York Heart Association (NYHA) class III heart failure. All patients were implanted with a pulmonary artery (PA) pressure monitoring system and randomized to a treatment and control groups. In the treatment group, physicians used the hemodynamic information to make heart failure management decisions. This information was not available to physicians for the control group. During an average of 18 month randomized follow-up, 27 patients required LVAD implantation. At the time of PA pressure sensor implantation, patients ultimately requiring advanced therapy had higher PA pressures, lower systemic pressure, and similar cardiac output measurements. Treatment and control patients in the LVAD subgroup had similar clinical profiles at the time of enrollment. There was a trend toward a shorter length of time to LVAD implantation in the treatment group when hemodynamic information was available. After LVAD implantation, most treatment group patients continued to provide physicians with physiologic information from the hemodynamic monitoring system. As expected PA pressures declined significantly post LVAD implant in all patients, but the magnitude of decline was higher in patients with PA pressure monitoring. Implantable hemodynamic monitoring appeared to improve the timing of LVAD implantation as well as optimize LVAD performance when compared with current methods. Further studies are necessary to evaluate these findings in a prospective manner.
引用
收藏
页码:301 / 308
页数:8
相关论文
共 19 条
[1]   Sustained efficacy of pulmonary artery pressure to guide adjustment of chronic heart failure therapy: complete follow-up results from the CHAMPION randomised trial [J].
Abraham, William T. ;
Stevenson, Lynne W. ;
Bourge, Robert C. ;
Lindenfeld, Jo Ann ;
Bauman, Jordan G. ;
Adamson, Philip B. .
LANCET, 2016, 387 (10017) :453-461
[2]   Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: a randomised controlled trial [J].
Abraham, William T. ;
Adamson, Philip B. ;
Bourge, Robert C. ;
Aaron, Mark F. ;
Costanzo, Maria Rosa ;
Stevenson, Lynne W. ;
Strickland, Warren ;
Neelagaru, Suresh ;
Raval, Nirav ;
Krueger, Steven ;
Weiner, Stanislav ;
Shavelle, David ;
Jeffries, Bradley ;
Yadav, Jay S. .
LANCET, 2011, 377 (9766) :658-666
[3]   Remote haemodynamic-guided care for patients with chronic heart failure: a meta-analysis of completed trials [J].
Adamson, Philip B. ;
Ginn, Greg ;
Anker, Stefan D. ;
Bourge, Robert C. ;
Abraham, William T. .
EUROPEAN JOURNAL OF HEART FAILURE, 2017, 19 (03) :426-433
[4]   Pulmonary Artery Pressure-Guided Heart Failure Management Reduces 30-Day Readmissions [J].
Adamson, Philip B. ;
Abraham, William T. ;
Stevenson, Lynne Warner ;
Desai, Akshay S. ;
Lindenfeld, JoAnn ;
Bourge, Robert C. ;
Bauman, Jordan .
CIRCULATION-HEART FAILURE, 2016, 9 (06)
[5]   Wireless Pulmonary Artery Pressure Monitoring Guides Management to Reduce Decompensation in Heart Failure With Preserved Ejection Fraction [J].
Adamson, Philip B. ;
Abraham, William T. ;
Bourge, Robert C. ;
Costanzo, Maria Rosa ;
Hasan, Ayesha ;
Yadav, Chethan ;
Henderson, John ;
Cowart, Pam ;
Stevenson, Lynne Warner .
CIRCULATION-HEART FAILURE, 2014, 7 (06) :935-944
[6]   CHAMPION Trial Rationale and Design: The Long-Term Safety and Clinical Efficacy of a Wireless Pulmonary Artery Pressure Monitoring System [J].
Adamson, Philip B. ;
Abraham, William T. ;
Aaron, Mark ;
Aranda, Juan M., Jr. ;
Bourge, Robert C. ;
Smith, Andrew ;
Stevenson, Lynne W. ;
Bauman, Jordan G. ;
Yadav, Jay S. .
JOURNAL OF CARDIAC FAILURE, 2011, 17 (01) :3-10
[7]   Randomized controlled trial of an implantable continuous hemodynamic monitor in patients with advanced heart failure - The COMPASS-HF study [J].
Bourge, Robert C. ;
Abraham, William T. ;
Adamson, Philip B. ;
Aaron, Mark F. ;
Aranda, Juan M., Jr. ;
Magalski, Anthony ;
Zile, Michael R. ;
Smith, Andrew L. ;
Smart, Frank W. ;
O'Shaughnessy, Mark A. ;
Jessup, Mariell L. ;
Sparks, Brandon ;
Naftel, David L. ;
Stevenson, Lynne Warner .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (11) :1073-1079
[8]   Interventions Linked to Decreased Heart Failure Hospitalizations During Ambulatory Pulmonary Artery Pressure Monitoring [J].
Costanzo, Maria R. ;
Stevenson, Lynne W. ;
Adamson, Philip B. ;
Desai, Akshay S. ;
Heywood, J. Thomas ;
Bourge, Robert C. ;
Bauman, Jordan ;
Abraham, William T. .
JACC-HEART FAILURE, 2016, 4 (05) :333-344
[9]   Chronic monitoring of pulmonary artery pressure in patients with severe heart failure: multicentre experience of the monitoring Pulmonary Artery Pressure by Implantable device Responding to Ultrasonic Signal (PAPIRUS) II study [J].
Hoppe, U. C. ;
Vanderheyden, M. ;
Sievert, H. ;
Brandt, M. C. ;
Tobar, R. ;
Wijns, W. ;
Rozenman, Y. .
HEART, 2009, 95 (13) :1091-1097
[10]   2009 Focused Update Incorporated Into the ACC/AHA 2005 Guidelines for the Diagnosis and Management of Heart Failure in Adults A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines Developed in Collaboration With the International Society for Heart and Lung Transplantation [J].
Hunt, Sharon Ann ;
Abraham, William T. ;
Chin, Marshall H. ;
Feldman, Arthur M. ;
Francis, Gary S. ;
Ganiats, Theodore G. ;
Jessup, Mariell ;
Konstam, Marvin A. ;
Mancini, Donna M. ;
Michl, Keith ;
Oates, John A. ;
Rahko, Peter S. ;
Silver, Marc A. ;
Stevenson, Lynne Warner ;
Yancy, Clyde W. ;
Casey, Donald E. ;
Smith, Sidney C., Jr. ;
Jacobs, Alice K. ;
Buller, Christopher E. ;
Creager, Mark A. ;
Ettinger, Steven M. ;
Krumholz, Harlan M. ;
Kushner, Frederick G. ;
Lytle, Bruce W. ;
Nishimura, Rick A. ;
Page, Richard L. ;
Tarkington, Lynn G. ;
Lewin, John C. ;
May, Charlene ;
Stewart, Mark D. ;
Keller, Sue ;
McDougall, Allison ;
Brown, Nancy ;
Whitman, Gayle R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (15) :E1-E90