Palmar angular stable plate fixation of nonunions and comminuted fractures of the scaphoid

被引:0
|
作者
Quadlbauer, S. [1 ,2 ,3 ]
Pezzei, C. [1 ]
Jurkowitsch, J. [1 ]
Krimmer, H. [4 ]
Sauerbier, M. [5 ]
Hausner, T. [1 ,2 ,3 ,5 ,6 ]
Leixnering, M. [1 ]
机构
[1] AUVA Unfallkrankenhaus Lorenz Bohler, European Hand Trauma Ctr, Donaueschingenstr 13, A-1200 Vienna, Austria
[2] AUVA Res Ctr, Ludwig Boltzmann Inst Expt & Klin Traumatol, Vienna, Austria
[3] Austrian Cluster Tissue Regenerat, Vienna, Austria
[4] St Elisabeth Klinikum Ravensburg, Zentrum Handchirurg, Ravensburg, Germany
[5] BG Unfallklin Frankfurt Main, Abt Plast Hand & Rekonstrukt Chirurg, Frankfurt, Germany
[6] Paracelsius Med Univ, Abt Orthopadie & Traumatol, Salzburg, Austria
来源
OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE | 2019年 / 31卷 / 05期
关键词
Bone graft; Scaphoid; Non union; Rotational stability; Plate; VASCULARIZED BONE-GRAFT; INTERNAL-FIXATION; SCREW FIXATION; PROXIMAL POLE; DISTAL RADIUS; NON-UNIONS; WAIST; PSEUDOARTHROSIS; RELIABILITY; MANAGEMENT;
D O I
10.1007/s00064-019-00623-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Stabilization of comminuted fractures and nonunions of the scaphoid with an angular stable low-profile scaphoid plate. Indications Scaphoid nonunions with a large palmar defect, second and third surgical procedure after previous stabilization by headless compression screw (HCS). Comminuted fractures of the scaphoid that cannot be sufficiently stabilized by screws. Contraindications Radio- and midcarpal osteoarthritis, small proximal pole fragments, fragmentation of the proximal pole. Surgical technique The scaphoid is accessed by a palmar approach. After correcting the DISI (dorsal intercalated segment instability) deformity of the lunate and humpback deformity of the scaphoid, the reduction is secured by temporary Kirschner wires. The nonunion is debrided and the bone defect filled with cancellous bone graft. Subsequently the scaphoid plate and the angular stable screw are positioned in the order to place three screws in the proximal and distal fragment of the scaphoid. Comminuted fractures of the scaphoid are fixated by temporary Kirschner wires, then the plate is positioned in the same way as nonunions. Postoperative management Comminuted fractures and nonunions of the scaphoid are immobilized by a below-elbow cast or thermoplastic splint with inclusion of the thumb for 8 weeks. No heavy work, high-risk or contact sport activities for 12 weeks. Plate removal is recommended after 6 months or after bony healing. Results By stabilizing scaphoid nonunions with a plate, high union rates with good clinical outcome can be achieved if the indication is correct.
引用
收藏
页码:433 / 446
页数:14
相关论文
共 50 条
  • [41] Headless Compression Screw Fixation of Scaphoid Fractures
    Fowler, John R.
    Ilyas, Asif M.
    HAND CLINICS, 2010, 26 (03) : 351 - +
  • [42] An Alternative Graft Fixation Technique for Scaphoid Nonunions Treated With Vascular Bone Grafting
    Korompilias, Anastasios V.
    Lykissas, Marios G.
    Kostas-Agnantis, Ioannis P.
    Gkiatas, Ioannis
    Beris, Alexandros E.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (07): : 1308 - 1312
  • [43] Dual plate fixation results in improved union rates in comminuted distal femur fractures compared to single plate fixation
    Bologna, Matthew Gregory
    Claudio, Mariano Garay
    Shields, Kelly J.
    Katz, Curren
    Salopek, Traci
    Westrick, Edward Ryan
    JOURNAL OF ORTHOPAEDICS, 2020, 18 : 76 - 79
  • [44] Evaluation of Herbert screw fixation for the treatment of displaced scaphoid nonunions
    Feldman, MD
    Manske, PR
    Welch, RL
    Szerzinski, JM
    ORTHOPEDICS, 1997, 20 (04) : 325 - 328
  • [45] Comparison of angle stable plate fixation approaches for distal radius fractures
    Matschke, S.
    Wentzensen, A.
    Ring, D.
    Marent-Huber, M.
    Audige, L.
    Jupiter, J. B.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (04): : 385 - 392
  • [46] Streamlining Definitive Care for Occult Scaphoid Fractures: A Retrospective Review of the Workup of Scaphoid Nonunions and Applying Lessons Learned
    Peterson, Shian Liu
    Donoughe, John Scott
    O'Neal, Derrick
    Mombell, Kyle
    GomezLeonardelli, Dominic
    MILITARY MEDICINE, 2020, 185 (7-8) : E958 - E962
  • [47] Anterior-inferior plate fixation of middle-third fractures and nonunions of the clavicle
    Collinge, Cory
    Devinney, Scott
    Herscovici, Dolfi
    DiPasquale, Thomas
    Sanders, Roy
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2006, 20 (10) : 680 - 686
  • [48] RETROSPECTIVE REVIEW OF 234 SCAPHOID FRACTURES AND NONUNIONS TREATED WITH ARTHROSCOPY FOR UNION AND COMPLICATIONS
    Slade, J. E., III
    Gillon, T.
    SCANDINAVIAN JOURNAL OF SURGERY, 2008, 97 (04) : 280 - 289
  • [49] Volar percutaneous transtrapezial fixation of scaphoid waist fractures : surgical technique
    Geurts, Ghislain F. A. E.
    Van Riet, Roger P.
    Meermans, Geert
    Verstreken, Frederik
    ACTA ORTHOPAEDICA BELGICA, 2012, 78 (01): : 121 - 125
  • [50] Angular-stable locking plate fixation of tibial plateau fractures-clinical and radiological midterm results in 101 patients
    Maerdian, Sven
    Landmann, Felix
    Wichlas, Florian
    Haas, Norbert P.
    Schaser, Klaus-Dieter
    Schwabe, Philipp
    INDIAN JOURNAL OF ORTHOPAEDICS, 2015, 49 (06) : 620 - 629