Effect of cooling water loop on the thermal performance of air conditioning system

被引:12
|
作者
Siricharoenpanich, A. [1 ]
Wiriyasart, S. [2 ]
Prurapark, R. [3 ]
Naphon, P. [2 ]
机构
[1] Rajamangala Univ Technol Isan, Fac Tech Educ, Dept Mech Engn, Appl Thermal & Heat Transfer Enhancement Res Lab, KhonKaen Campus,150 Sichang Rd, Khon Kaen 40000, Thailand
[2] Srinakharinwirot Univ, Dept Mech Engn, Thermofluids & Heat Transfer Enhancement Res Lab, Fac Engn, 63 Rangsit Nakhornnayok Rd, Ongkharak 26120, Nakhorn Nayok, Thailand
[3] Srinakharinwirot Univ, Fac Engn, Dept Petr & Nat Gas Engn, 63 Rangsit Nakhornnayok Rd, Ongkharak 26120, Nakhorn Nayok, Thailand
关键词
Cooling water loop; Air conditioning system; COP; PIPE HEAT-EXCHANGER; ENERGY-CONSUMPTION; HUMIDITY CONTROL; SINK; COMPRESSOR; EFFICIENCY; RECOVERY;
D O I
10.1016/j.csite.2019.100518
中图分类号
O414.1 [热力学];
学科分类号
摘要
The aim of this research is to improve thermal performance of air conditioning system by cooling water loop. In experiment, the cooling water loop with the concentric helically coiled tube heat exchanger is installed between the compressor unit and condenser unit for cooling refrigerant before entering the condenser unit. Effects of water mass flow rate and atmospheric temperature on the COP are considered. The obtained results are compared with those from the conventional air conditioning system without cooling water loop. It can be seen that the COP tends to increase with increasing water mass flow rate and tend to decrease as atmospheric temperature increases. The highest COP is 31.02% as compared with the conventional reference system, respectively. In addition, not only COP of air conditioning system are increased but also the hot water storage is obtained which used for various applications. The results obtained this study are expected to lead to guidelines that will allow the improved thermal performance of air conditioning system and hot water storage system which reduce energy consumption.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Simulation of a VAV air conditioning system in an existing building for the cooling mode
    Aynur, Tolga N.
    Hwang, Yunho
    Radermacher, Reinhard
    ENERGY AND BUILDINGS, 2009, 41 (09) : 922 - 929
  • [32] Thermal performance of helicopter air conditioning system with lube oil source (LOS) heat pump
    Pang, Liping
    Luo, Kun
    Yuan, Yanping
    Mao, Xiaodong
    Fang, Yufeng
    ENERGY, 2020, 190
  • [33] Experimental investigation of PCM transient performance in free cooling of the fresh air of air conditioning systems
    Nada, S. A.
    Alshaer, W. G.
    Saleh, R. M.
    JOURNAL OF BUILDING ENGINEERING, 2020, 29
  • [34] An air-conditioning system performance enhancement by using heat pipe based heat recovery technology
    Ahmadzadehtalatapeh, M.
    SCIENTIA IRANICA, 2013, 20 (02) : 329 - 336
  • [35] Performance evaluation and life cycle analysis of new solar thermal absorption air conditioning system
    Rahman, Shek
    Said, Zafar
    Issa, Salah
    ENERGY REPORTS, 2020, 6 : 673 - 679
  • [36] Application of Vibration Reduction Technologies for Central Air Conditioning in Cooling Water Pumps
    Wang C.
    Tang Y.
    Hedongli Gongcheng/Nuclear Power Engineering, 2019, 40 (04): : 189 - 192
  • [37] Comparison of energy performance and economics of chilled water thermal storage and conventional air-conditioning systems
    Sebzali, M. J.
    Ameer, B.
    Hussain, H. J.
    ENERGY AND BUILDINGS, 2014, 69 : 237 - 250
  • [38] Improvement of Performance of Air Conditioning System with Modification in Condenser
    Mani, Purusothaman
    Madhubalan, G.
    Parameswaran, T.
    Ponnappan, Venkatesan Sorakka
    Gnanamani, Senthilkumar
    Natesan, Valarmathi Thirumalai
    3RD INTERNATIONAL CONFERENCE ON FRONTIERS IN AUTOMOBILE AND MECHANICAL ENGINEERING (FAME 2020), 2020, 2311
  • [39] Simulation of air-cooled PV/T air conditioning system for cooling and power cogeneration
    Fan, Man
    Feng, Guanyuan
    Xu, Jianwei
    Yang, Hua
    Kong, Xiangfei
    Li, Han
    APPLIED THERMAL ENGINEERING, 2023, 224
  • [40] A case study for influence of building thermal insulation on cooling load and air-conditioning system in the hot and humid regions
    Aktacir, Mehmet Azmi
    Buyukalaca, Orhan
    Yilmaz, Tuncay
    APPLIED ENERGY, 2010, 87 (02) : 599 - 607