Coherent-weighted three-dimensional image reconstruction in linear-array-based photoacoustic tomography

被引:35
作者
Wang, Depeng [1 ]
Wang, Yuehang [1 ]
Zhou, Yang [1 ,2 ]
Lovell, Jonathan F. [1 ]
Xia, Jun [1 ]
机构
[1] SUNY Buffalo, Univ Buffalo, Dept Biomed Engn, Buffalo, NY USA
[2] Shandong Normal Univ, Shandong Prov Key Lab Clean Prod Fine Chem,Minist, Coll Chem Chem Engn & Mat Sci,Key Lab Mol & Nano, Collaborat Innovat Ctr Functionalized Probes Chem, Jinan, Peoples R China
基金
美国国家卫生研究院; 中国国家自然科学基金;
关键词
1000; NM; RESOLUTION;
D O I
10.1364/BOE.7.001957
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
While the majority of photoacoustic imaging systems used custom-made transducer arrays, commercially-available linear transducer arrays hold the benefits of affordable price, handheld convenience and wide clinical recognition. They are not widely used in photoacoustic imaging primarily because of the poor elevation resolution. Here, without modifying the imaging geometry and system, we propose addressing this limitation purely through image reconstruction. Our approach is based on the integration of two advanced image reconstruction techniques: focal-line-based three-dimensional image reconstruction and coherent weighting. We first numerically validated our approach through simulation and then experimentally tested it in phantom and in vivo. Both simulation and experimental results proved that the method can significantly improve the elevation resolution (up to 4 times in our experiment) and enhance object contrast. (C) 2016 Optical Society of America
引用
收藏
页码:1957 / 1965
页数:9
相关论文
共 16 条
[1]  
[Anonymous], 10 NORD C BIOM 1 S1
[2]   Design, Synthesis, and Properties of Phthalocyanine Complexes with Main-Group Elements Showing Main Absorption and Fluorescence beyond 1000 nm [J].
Furuyama, Taniyuki ;
Satoh, Koh ;
Kushiya, Tomofumi ;
Kobayashi, Nagao .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2014, 136 (02) :765-776
[3]   Single-side access, isotropic resolution, and multispectral three-dimensional photoacoustic imaging with rotate-translate scanning of ultrasonic detector array [J].
Gateau, Jerome ;
Gesnik, Marc ;
Chassot, Jean-Marie ;
Bossy, Emmanuel .
JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (05)
[4]   Three-dimensional optoacoustic tomography using a conventional ultrasound linear detector array: Whole-body tomographic system for small animals [J].
Gateau, Jerome ;
Caballero, Miguel Angel Araque ;
Dima, Alexander ;
Ntziachristos, Vasilis .
MEDICAL PHYSICS, 2013, 40 (01)
[5]   CALCULATION OF PRESSURE FIELDS FROM ARBITRARILY SHAPED, APODIZED, AND EXCITED ULTRASOUND TRANSDUCERS [J].
JENSEN, JA ;
SVENDSEN, NB .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (02) :262-267
[6]  
Li M.-L., 2008, BIOMEDICAL OPTICS BI
[7]   Optoacoustic imaging with synthetic aperture focusing and coherence weighting [J].
Liao, CK ;
Li, ML ;
Li, PC .
OPTICS LETTERS, 2004, 29 (21) :2506-2508
[8]   ADAPTIVE FOCUSING IN SCATTERING MEDIA THROUGH SOUND-SPEED INHOMOGENEITIES - THE VANCITTERT-ZERNIKE APPROACH AND FOCUSING CRITERION [J].
MALLART, R ;
FINK, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1994, 96 (06) :3721-3732
[9]  
Schwarz M, 2015, J BIOPHOTONICS, V8, P60, DOI [10.1002/jbio.201400021, 10.1002/jbio.201500247]
[10]   Review on photoacoustic imaging of the brain using nanoprobes [J].
Wang, Depeng ;
Wu, Yun ;
Xia, Jun .
NEUROPHOTONICS, 2016, 3 (01)