Stationary Computed Tomography for Space and other Resource-constrained Environments

被引:32
作者
Cramer, Avilash [1 ,2 ]
Hecla, Jake [1 ]
Wu, Dufan [2 ,3 ]
Lai, Xiaochun [2 ,3 ]
Boers, Tim [5 ]
Yang, Kai [2 ,3 ]
Moulton, Tim [3 ,4 ]
Kenyon, Steven [6 ]
Arzoumanian, Zaven [6 ]
Krull, Wolfgang [3 ,4 ]
Gendreau, Keith [6 ]
Gupta, Rajiv [2 ,3 ,4 ]
机构
[1] MIT, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[2] Harvard Med Sch, Boston, MA 20115 USA
[3] Massachusetts Gen Hosp, Boston, MA 02114 USA
[4] Consortia Improving Med Innovat Technol, Boston, MA 02114 USA
[5] Univ Twente, NL-7522 NB Enschede, Netherlands
[6] NASA, Goddard Space Flight Ctr, Greenbelt, MD 02771 USA
基金
美国国家卫生研究院;
关键词
STROKE; EXPERIENCE; BRAIN; TIME; CT;
D O I
10.1038/s41598-018-32505-z
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Computed tomography (CT) is used to diagnose many emergent medical conditions, including stroke and traumatic brain injuries. Unfortunately, the size, weight, and expense of CT systems make them largely inaccessible for patients outside of major hospitals. We have designed a module containing multiple miniature x-ray sources that could allow for CT systems to be significantly lighter, smaller, and cheaper, and to operate without any moving parts. We have developed a novel photocathode-based x-ray source, created by depositing a thin film of magnesium on an electron multiplier. When illuminated by a UV LED, this photocathode emits a beam of electrons, with a beam current of up to 1 mA. The produced electrons are accelerated through a high voltage to a tungsten target. These sources are individually addressable and can be pulsed rapidly, through electronic control of the LEDs. Seven of these sources are housed together in a 17.5 degree arc within a custom vacuum manifold. A full ring of these modules could be used for CT imaging. By pulsing the sources in series, we are able to demonstrate x-ray tomosynthesis without any moving parts. With a clinical flat-panel detector, we demonstrate 3D acquisition and reconstructions of a cadaver swine lung.
引用
收藏
页数:10
相关论文
共 34 条
[1]  
Bagg Mark R, 2006, J Am Acad Orthop Surg, V14, pS7
[2]   Degradation and failure of carbon nanotube field emitters [J].
Bonard, JM ;
Klinke, C ;
Dean, KA ;
Coll, BF .
PHYSICAL REVIEW B, 2003, 67 (11) :10
[3]   Benefits of Stroke Treatment Using a Mobile Stroke Unit Compared With Standard Management The BEST-MSU Study Run-In Phase [J].
Bowry, Ritvij ;
Parker, Stephanie ;
Rajan, Suja S. ;
Yamal, Jose-Miguel ;
Wu, Tzu-Ching ;
Richardson, Laura ;
Noser, Elizabeth ;
Persse, David ;
Jackson, Kamilah ;
Grotta, James C. .
STROKE, 2015, 46 (12) :3370-3374
[4]  
Foale CM, 2005, AVIAT SPACE ENVIR MD, V76, P594
[5]  
Folio LR, 2010, COMBAT RADIOLOGY: DIAGNOSTIC IMAGING OF BLAST AND BALLISTIC INJURIES, P1, DOI 10.1007/978-1-4419-5854-9
[6]   The Massachusetts General Hospital acute stroke imaging algorithm: an experience and evidence based approach [J].
Gonzalez, Ramon Gilberto ;
Copen, William A. ;
Schaefer, Pamela W. ;
Lev, Michael H. ;
Pomerantz, Stuart R. ;
Rapalino, Otto ;
Chen, John W. ;
Hunter, George J. ;
Romero, Javier M. ;
Buchbinder, Bradley R. ;
Larvie, Mykol ;
Hirsch, Joshua Adam ;
Gupta, Rajiv .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 :7-12
[7]  
Hart R, 2002, AVIAT SPACE ENVIR MD, V73, P601
[8]   Performance of CT Angiography on a Mobile Stroke Treatment Unit: Implications for Triage [J].
John, Seby ;
Stock, Sarah ;
Masaryk, Thomas ;
Bauer, Andrew ;
Cerejo, Russell ;
Uchino, Ken ;
Winners, Stacey ;
Rasmussen, Peter ;
Hussain, Muhammad S. .
JOURNAL OF NEUROIMAGING, 2016, 26 (04) :391-394
[9]   X-ray computed tomography [J].
Kalender, Willi A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (13) :R29-R43
[10]   First-Photon Imaging [J].
Kirmani, Ahmed ;
Venkatraman, Dheera ;
Shin, Dongeek ;
Colaco, Andrea ;
Wong, Franco N. C. ;
Shapiro, Jeffrey H. ;
Goyal, Vivek K. .
SCIENCE, 2014, 343 (6166) :58-61