Digital breast tomosynthesis

被引:0
作者
Preibsch, H. [1 ]
Siegmann-Luz, K. C. [2 ,3 ]
机构
[1] Univ Klinikum Tubingen, Abt Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[2] Diagnost Brustzentrum, Konigs Wusterhause, Germany
[3] Mammografiescreening Brandenburg, Konigs Wusterhause, Germany
来源
RADIOLOGE | 2015年 / 55卷 / 01期
关键词
Breast neoplasms; Screening; Mammography; Diagnostic accuracy; Early detection of cancer; MAMMOGRAPHY; 2-VIEW; COMBINATION; PERFORMANCE; ACCURACY; WOMEN;
D O I
10.1007/s00117-014-2753-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In digital breast tomosynthesis several low dose mammograms are acquired from different angles to calculate thin slices of synthetic mammograms from algorithms. Similar to computed tomography and magnetic resonance imaging, breast tomosynthesis provides breast images which are virtually free from superimposition. This is in particular important in cases of high mammographic density to differentiate real masses and architectural distortions from the overlying parenchyma. In comparison to full field digital mammography tomosynthesis can improve the cancer detection rate and reduce the recall rate. The limitations of tomosynthesis are the higher radiation dose and the longer reporting time compared to full field digital mammography. Until the radiation dose can be significantly reduced it is advisable to use tomosynthesis in addition to full field digital mammography primarily for the assessment of suspicious mammographic findings and not for breast cancer screening.
引用
收藏
页码:59 / 69
页数:11
相关论文
共 32 条
[1]  
[Anonymous], 2012, INT S3 LEITL DIAGN T
[2]  
[Anonymous], SEL DIM 3D SYST P080
[3]   Breast Tomosynthesis: State-of-the-Art and Review of the Literature [J].
Baker, Jay A. ;
Lo, Joseph Y. .
ACADEMIC RADIOLOGY, 2011, 18 (10) :1298-1310
[4]   Application of breast tomosynthesis in screening: incremental effect on mammography acquisition and reading time [J].
Bernardi, D. ;
Ciatto, S. ;
Pellegrini, M. ;
Anesi, V. ;
Burlon, S. ;
Cauli, E. ;
Depaoli, M. ;
Larentis, L. ;
Malesani, V. ;
Targa, L. ;
Baldo, P. ;
Houssami, N. .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1020) :E1174-E1178
[5]   Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study [J].
Ciatto, Stefano ;
Houssami, Nehmat ;
Bernardi, Daniela ;
Caumo, Francesca ;
Pellegrini, Marco ;
Brunelli, Silvia ;
Tuttobene, Paola ;
Bricolo, Paola ;
Fanto, Carmine ;
Valentini, Marvi ;
Montemezzi, Stefania ;
Macaskill, Petra .
LANCET ONCOLOGY, 2013, 14 (07) :583-589
[6]   Addition of Tomosynthesis to Conventional Digital Mammography: Effect on Image Interpretation Time of Screening Examinations [J].
Dang, Pragya A. ;
Freer, Phoebe E. ;
Humphrey, Kathryn L. ;
Halpern, Elkan F. ;
Rafferty, Elizabeth A. .
RADIOLOGY, 2014, 270 (01) :49-56
[7]  
European Reference Organisation for Quality Assured Breast Screening and Diagnostic Services, 2014, PROT QUAL CONTR PHYS
[8]   Breast tomosynthesis: Accuracy of tumor measurement compared with digital mammography and ultrasonography [J].
Fornvik, Daniel ;
Zackrisson, Sophia ;
Ljungberg, Otto ;
Svahn, Tony ;
Timberg, Pontus ;
Tingberg, Anders ;
Andersson, Ingvar .
ACTA RADIOLOGICA, 2010, 51 (03) :240-247
[9]   Breast Cancer Screening Using Tomosynthesis in Combination With Digital Mammography [J].
Friedewald, Sarah M. ;
Rafferty, Elizabeth A. ;
Rose, Stephen L. ;
Durand, Melissa A. ;
Plecha, Donna M. ;
Greenberg, Julianne S. ;
Hayes, Mary K. ;
Copit, Debra S. ;
Carlson, Kara L. ;
Cink, Thomas M. ;
Barke, Lora D. ;
Greer, Linda N. ;
Miller, Dave P. ;
Conant, Emily F. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 311 (24) :2499-2507
[10]   Digital breast tomosynthesis versus digital mammography: a clinical performance study [J].
Gennaro, Gisella ;
Toledano, Alicia ;
di Maggio, Cosimo ;
Baldan, Enrica ;
Bezzon, Elisabetta ;
La Grassa, Manuela ;
Pescarini, Luigi ;
Polico, Ilaria ;
Proietti, Alessandro ;
Toffoli, Aida ;
Muzzio, Pier Carlo .
EUROPEAN RADIOLOGY, 2010, 20 (07) :1545-1553