Criteria of spot asymmetry in proton radiotherapy pencil beam scanning - a Monte Carlo study

被引:0
作者
Klodowska, M. [1 ]
Gajewski, J. [1 ]
Skowronska, K. [1 ]
Olko, P. [1 ]
机构
[1] Polish Acad Sci, Inst Nucl Phys, Radzikowskiego 152, PL-31342 Krakow, Poland
关键词
proton radiotherapy; spot asymmetry; Monte Carlo;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
118
引用
收藏
页码:S57 / S58
页数:2
相关论文
共 50 条
  • [1] A Monte Carlo study on the collimation of pencil beam scanning proton therapy beams
    Charlwood, Frances C.
    Aitkenhead, Adam H.
    Mackay, Ranald I.
    MEDICAL PHYSICS, 2016, 43 (03) : 1462 - 1472
  • [2] Fetal dose from proton pencil beam scanning craniospinal irradiation during pregnancy: a Monte Carlo study
    Yeom, Yeon Soo
    Griffin, Keith T.
    Mille, Matthew M.
    Lee, Choonik
    O'Reilly, Shannon
    Dong, Lei
    Jung, Jae Won
    Lee, Choonsik
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (03)
  • [3] Validation and clinical implementation of an accurate Monte Carlo code for pencil beam scanning proton therapy
    Huang, Sheng
    Kang, Minglei
    Souris, Kevin
    Ainsley, Christopher
    Solberg, Timothy D.
    McDonough, James E.
    Simone, Charles B.
    Lin, Liyong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05): : 558 - 572
  • [4] An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle
    Sawakuchi, Gabriel O.
    Mirkovic, Dragan
    Perles, Luis A.
    Sahoo, Narayan
    Zhu, X. Ron
    Ciangaru, George
    Suzuki, Kazumichi
    Gillin, Michael T.
    Mohan, Radhe
    Titt, Uwe
    MEDICAL PHYSICS, 2010, 37 (09) : 4960 - 4970
  • [5] Development and validation of the Dynamic Collimation Monte Carlo simulation package for pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Yu, Jen
    Rana, Suresh
    Gutierrez, Alonso N.
    Hill, Patrick M.
    MEDICAL PHYSICS, 2021, 48 (06) : 3172 - 3185
  • [6] Experimental and Monte Carlo characterization of a dynamic collimation system prototype for pencil beam scanning proton therapy
    Smith, Blake R.
    Pankuch, Mark
    Hyer, Daniel E.
    Culberson, Wesley S.
    MEDICAL PHYSICS, 2020, 47 (10) : 5343 - 5356
  • [7] Absolute dosimetry for FLASH proton pencil beam scanning radiotherapy
    Lourenco, Ana
    Subiel, Anna
    Lee, Nigel
    Flynn, Sam
    Cotterill, John
    Shipley, David
    Romano, Francesco
    Speth, Joe
    Lee, Eunsin
    Zhang, Yongbin
    Xiao, Zhiyan
    Mascia, Anthony
    Amos, Richard A.
    Palmans, Hugo
    Thomas, Russell
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [8] Proton microbeam radiotherapy with scanned pencil-beams - Monte Carlo simulations
    Klodowska, M.
    Olko, P.
    Waligorski, M. P. R.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (06): : 621 - 626
  • [9] Dosimetric comparison of pencil beam and Monte Carlo algorithms in conformal lung radiotherapy
    Elcim, Yelda
    Dirican, Bahar
    Yavas, Omer
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05): : 616 - 624
  • [10] Evaluation of monte carlo to support commissioning of the treatment planning system of new pencil beam scanning proton therapy facilities
    Botnariuc, D.
    Court, S.
    Lourenco, A.
    Gosling, A.
    Royle, G.
    Hussein, M.
    Rompokos, V
    Veiga, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (04)