Influence of different low-pressure plasma process parameters on shear bond strength between veneering composites and PEEK materials

被引:53
作者
Boetel, Friederike
Zimmermann, Tycho
Suetel, Mona
Mueller, Wolf-Dieter [1 ]
Schwitalla, Andreas Dominik
机构
[1] Charite Univ Med Berlin, Freie Univ Berlin, Humboldt Univ Berlin, Assmannshauser Str 4-6, D-14197 Berlin, Germany
关键词
Oxygen low pressure plasma; Argon/oxygen low-pressure plasma; PEEK; Shear bond strength; Veneering procedure; Prosthetic restoration; POLYETHERETHERKETONE; TITANIUM; PRETREATMENT; PROSTHESIS; IMPLANTS; IMPACT; RESINS;
D O I
10.1016/j.dental.2018.06.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The aim of this study was to evaluate the impact of oxygen and argon/oxygen low-pressure plasma on the shear bond strength (SBS) between dental PEEK compounds and veneering composites as a function of plasma process time. Methods. Of an unfilled PEEK ("Juvora") and two pigment powder filled PEEK compounds ("DC4420", "DC4450"), 273 rectangular plates were prepared and polished up to 1200 grit. Afterwards the samples were sandblasted and randomly assigned to five different surface pre-treatment groups (1. No plasma (control); 2. O-2 plasma for 3 min; 3. O-2 plasma for 35 min; 4. Ar/O-2 plasma for 3 min; 5. Ar/O-2 plasma for 35 min). Surface roughness and water contact angles were recorded using three samples of each PEEK compound for each of the plasma treatment groups. An adhesive (visio.link, Bredent GmbH & Co KG, Senden, Germany) was applied onto the specimen surfaces and light cured. A mold was used to shape three different veneering composites (a) Vita VM LC, "Vita" (Vita Zahnfabrik, Bad Sackingen, Germany); (b) GC GRADIA, "Gradia" (GC Europe, Leuven, Belgium); (c) GC GRADIA DIRECT Flo, "Gradia Flo" (GC Europe, Leuven, Belgium)) into a cylindrical form on the sample surface before light curing. SBS was measured using a universal testing machine after 24 h of incubation in distilled water at 37 degrees C. Results. The two pigment filled PEEK compounds treated with O-2 plasma and veneered with Gradia Flo showed the highest SBS values (34.92 +/- 6.55 MPa and 34.2 +/- 1.87 MPa) followed by the combination of the unfilled PEEK material with Gradia Flo (29.57 +/- 3.71 MPa). The SBS values of the samples veneered with Gradia were lower, but not significantly so. The SBS values of the specimens with Vita were for the most part associated with significantly lower results. Significance. A low-pressure plasma process using oxygen plasma for a duration of 35 min, preceded by sandblasting, seems to be the most effective in increasing shear bond strength between veneering composites and PEEK materials. (C) 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:E246 / E254
页数:9
相关论文
共 33 条
  • [1] Are ceramic implants a viable alternative to titanium implants? A systematic literature review
    Andreiotelli, Marina
    Wenz, Hans J.
    Kohal, Ralf-Joachim
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 : 32 - 47
  • [2] Andrikopoulou E, 2016, J ESTHET RESTOR DENT, V28, P201, DOI 10.1111/jerd.12221
  • [3] [Anonymous], WERKSTOFF FUHRER KUN
  • [4] Accuracy of CAD-CAM-fabricated removable partial dentures
    Arnold, Christin
    Hey, Jeremias
    Schweyen, Ramona
    Setz, Juergen M.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (04) : 586 - 592
  • [5] USE OF POLYETHERETHERKETONE IN THE FABRICATION OF A MAXILLARY OBTURATOR PROSTHESIS: A CLINICAL REPORT
    Costa-Palau, Santiago
    Torrents-Nicolas, Josep
    Brufau-de Barbera, Magi
    Cabratosa-Termes, Josep
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (03) : 680 - 682
  • [6] Eichner K., 1996, ZAHNARZTLICHE WERKST
  • [7] Atmospheric Pressure Plasma: A High-Performance Tool for the Efficient Removal of Biofilms
    Fricke, Katja
    Koban, Ina
    Tresp, Helena
    Jablonowski, Lukasz
    Schroeder, Karsten
    Kramer, Axel
    Weltmann, Klaus-Dieter
    von Woedtke, Thomas
    Kocher, Thomas
    [J]. PLOS ONE, 2012, 7 (08):
  • [8] Titanium Allergy: A Literature Review
    Goutam, Manish
    Giriyapura, Chandu
    Mishra, Sunil Kumar
    Gupta, Siddharth
    [J]. INDIAN JOURNAL OF DERMATOLOGY, 2014, 59 (06) : 630
  • [9] Interim rehabilitation of occlusal vertical dimension using a double-crown-retained removable dental prosthesis with polyetheretherketone framework
    Hahne, Sebastian
    Scherl, Christian
    Rosentritt, Martin
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (03) : 315 - 318
  • [10] The improvement of adhesive properties of PEEK through different pre-treatments
    Hallmann, Lubica
    Mehl, Albert
    Sereno, Nuno
    Haemmerle, Christoph H. F.
    [J]. APPLIED SURFACE SCIENCE, 2012, 258 (18) : 7213 - 7218