Intracoronary thrombus formation after drug-eluting stents implantation: Optical coherence tomographic study

被引:40
作者
Kim, Jung-Sun [1 ]
Hong, Myeong-Ki [1 ]
Fan, Chunyu [1 ]
Kim, Tae-Hoon [1 ]
Shim, Jae-Min [1 ]
Park, Sang-Min [1 ]
Ko, Young-Guk [1 ]
Choi, Donghoon [1 ]
Jang, Yangsoo [1 ]
机构
[1] Yonsei Univ, Coll Med, Div Cardiol, Yonsei Cardiovasc Ctr, Seoul 120752, South Korea
关键词
INCOMPLETE NEOINTIMAL COVERAGE;
D O I
10.1016/j.ahj.2009.11.029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Intracoronary thrombus formation after drug-eluting stent (DES) implantation is not sufficiently evaluated. Methods Optical coherence tomography (OCT) was performed in 226 patients (total DES n = 244, sirolimus-eluting stent [SES] n = 95, paclitaxel-eluting stent [PES] n = 62, zotarolimus-eluting stent [ZES] n = 87) after implantation (mean 11 months, range 3-66 months). Using OCT, we investigated the incidence and determinants of intracoronary thrombus. Results Intracoronary thrombus was detected in 35 (14%) cases (27 SES [28%], 7 PES [11%], and 1 ZES [1%], P < .001) and was associated with longer stent, smaller stent diameter, and stents at bifurcation lesions. More uncovered stent struts (26 +/- 23 vs 8 +/- 17, P < .001) and malapposed stent struts (6 +/- 14 vs 2 +/- 6, P < .001) were also associated with intracoronary thrombus. Multiple logistic regression analysis found the following determinants of intracoronary thrombus: stent length >= 28 mm (odds ratio [OR] 7.31, 95% CI 1.79-29.86, P = .01), stent diameter <3.0 mm (OR 4.38, 95% CI 1.38-13.97, P = .01), and = 8 uncovered struts in each stent (OR 3.29, 95% CI 1.07-10.17, P = .04). Conclusions Length, size, and types of DES may be more important than clinical factors in intracoronary thrombus formation after DES implantations. (Am Heart J 2010; 159: 278-83.)
引用
收藏
页码:278 / 283
页数:6
相关论文
共 19 条
[1]   Angioscopic comparison of neointimal coverage between zotarolimus- and sirolimus-eluting stents [J].
Awata, Masaki ;
Nanto, Shinsuke ;
Uematsu, Masaaki ;
Morozumi, Takakazu ;
Watanabe, Tetsuya ;
Onishi, Toshinari ;
Iida, Osamu ;
Sera, Fusako ;
Kotani, Jun-ichi ;
Hori, Masatsugu ;
Nagata, Seiki .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (09) :789-790
[2]   Serial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation [J].
Awata, Masaki ;
Kotani, Jun-ichi ;
Uematsu, Masaaki ;
Morozumi, Takakazu ;
Watanabe, Tetsuya ;
Onishi, Toshinari ;
Iida, Osamu ;
Sera, Fusako ;
Nanto, Shinsuke ;
Hori, Masatsugu ;
Nagata, Seiki .
CIRCULATION, 2007, 116 (08) :910-916
[3]   Pathological mechanisms of fatal late coronary stent thrombosis in humans [J].
Farb, A ;
Burke, AP ;
Kolodgie, FD ;
Virmani, R .
CIRCULATION, 2003, 108 (14) :1701-1706
[4]   Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization [J].
Finn, Aloke V. ;
Joner, Michael ;
Nakazawa, Gaku ;
Kolodgie, Frank ;
Newell, John ;
John, Mike C. ;
Gold, Herman K. ;
Virmani, Renu .
CIRCULATION, 2007, 115 (18) :2435-2441
[5]   Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents [J].
Iakovou, I ;
Schmidt, T ;
Bonizzoni, E ;
Ge, L ;
Sangiorgi, GM ;
Stankovic, G ;
Airoldi, F ;
Chieffo, A ;
Montorfano, M ;
Carlino, M ;
Michev, I ;
Corvaja, N ;
Briguori, C ;
Gerckens, U ;
Grube, E ;
Colombo, A .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (17) :2126-2130
[6]   Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: Comparison with intravascular ultrasound [J].
Jang, IK ;
Bouma, BE ;
Kang, DH ;
Park, SJ ;
Park, SW ;
Seung, KB ;
Choi, KB ;
Shishkov, M ;
Schlendorf, K ;
Pomerantsev, E ;
Houser, SL ;
Aretz, HT ;
Tearney, GJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (04) :604-609
[7]   Incomplete neointimal coverage of sirolimus-eluting stents - Angioscopic findings [J].
Kotani, Jun-ichi ;
Awata, Masaki ;
Nanto, Shinsuke ;
Uematsu, Masaaki ;
Oshima, Fusako ;
Minamiguchi, Hitoshi ;
Mintz, Gary S. ;
Nagata, Seiki .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (10) :2108-2111
[8]   Assessment of coronary arterial thrombus by optical coherence tomography [J].
Kume, Teruyoshi ;
Akasaka, Takashi ;
Kawamoto, Takahiro ;
Ogasawara, Yasuo ;
Watanabe, Nozorni ;
Toyota, Eiji ;
Neishi, Yoji ;
Sukmawan, Renan ;
Sadahira, Yoshito ;
Yoshida, Kiyoshi .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (12) :1713-1717
[9]   Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography [J].
Matsumoto, Daisuke ;
Shite, Junya ;
Shinke, Toshiro ;
Otake, Hiromasa ;
Tanino, Yusuke ;
Ogasawara, Daisuke ;
Sawada, Takahiro ;
Paredes, Oscar Luis ;
Hirata, Ken-ichi ;
Yokoyama, Mitsuhiro .
EUROPEAN HEART JOURNAL, 2007, 28 (08) :961-967
[10]   Stent thrombosis in randomized clinical trials of drug-eluting stents [J].
Mauri, Laura ;
Hsieh, Wen-hua ;
Massaro, Joseph M. ;
Ho, Kalon K. L. ;
D'Agostino, Ralph ;
Cutlip, Donald E. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (10) :1020-1029