Biomechanical investigation of vertebroplasty in osteoporotic compression fractures and in prophylactic vertebral reinforcement

被引:57
作者
Furtado, Navin
Oakland, Robert J. [1 ]
Wilcox, Ruth K.
Hall, Richard M.
机构
[1] Univ Leeds, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
[2] St James Univ Hosp, Acad Unit Orthopaed Surg, Leeds, W Yorkshire, England
关键词
osteoporosis; vertebral compression fracture; percutaneous vertebroplasty;
D O I
10.1097/BRS.0b013e31811ea2ee
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Cadaveric single vertebrae were used to evaluate vertebroplasty as a prophylactic treatment and as an intervention for vertebral compression fractures. Objective. To investigate the biomechanical characteristics of prophylactic reinforcement and postfracture augmentation of cadaveric vertebrae. Summary of Background Data. Percutaneous vertebroplasty is a treatment option for osteoporotic vertebral compression fractures. Short-term results are promising, but longer-term studies have suggested a possible accelerated failure rate in the adjacent vertebral body. Limited research has been conducted into the effects of prophylactic vertebroplasty in osteoporotic vertebrae. This study aims to elucidate the biomechanical differences between the 2 treatment groups. Methods. Human vertebrae were assigned to 2 scenarios: Scenario 1 simulated a wedge fracture followed by cement augmentation; Scenario 2 involved prophylactic augmentation using vertebroplasty. Micro-CT imaging was performed to assess the bone mineral density, vertebral dimensions, fracture pattern, and cement volume. All augmented specimens were then compressed under an eccentric flexion load to failure. Results. Product of bone mineral density and endplate surface area gave a good prediction of failure strength when compared with actual failure strength of specimens in Scenario 1. Augmented vertebral bodies showed an average cement fill of 23.9% +/- 8.07%. There was a significant postvertebroplasty increase in failure strength by a factor of 1.72 and 1.38 in Scenarios 1 and 2, respectively. There was a significant reduction in stiffness following augmentation for Scenario 1 (t = 3.5, P = 0.005). Stiffness of the vertebral body in Scenario 2 was significantly greater than observed in Scenario 1 (t = 4.4, P = 0.0002). Conclusion. Results suggest that augmentation of the vertebrae postfracture significantly increases failure load, while stiffness is not restored. Prophylactic augmentation was seen to increase failure strength in comparison to the predicted failure load. Stiffness appears to be maintained suggesting that prophylactic vertebroplasty maintains stiffness better than vertebroplasty postfracture.
引用
收藏
页码:E480 / E487
页数:8
相关论文
共 36 条
[21]   Complications of percutaneous vertebroplasty and their prevention [J].
Laredo, JD ;
Hamze, B .
SKELETAL RADIOLOGY, 2004, 33 (09) :493-505
[22]   Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty [J].
Liebschner, MAK ;
Rosenberg, WS ;
Keaveny, TM .
SPINE, 2001, 26 (14) :1547-1554
[23]   Quality of life following vertebroplasty [J].
McKiernan, F ;
Faciszewski, T ;
Jensen, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (12) :2600-2606
[24]   EPIDEMIOLOGY OF VERTEBRAL FRACTURES IN WOMEN [J].
MELTON, LJ ;
KAN, SH ;
FRYE, MA ;
WAHNER, HW ;
OFALLON, WM ;
RIGGS, BL .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1989, 129 (05) :1000-1011
[25]   The effect of vertebral body percentage fill on mechanical behavior during percutaneous vertebroplasty [J].
Molloy, S ;
Mathis, JM ;
Belkoff, SM .
SPINE, 2003, 28 (14) :1549-1554
[26]  
Molloy S, 2005, AM J NEURORADIOL, V26, P401
[27]  
Old JL, 2004, AM FAM PHYSICIAN, V69, P111
[28]   Diagnosis and management of vertebral fractures in elderly adults [J].
Papaioannou, A ;
Watts, NB ;
Kendler, DL ;
Yuen, CK ;
Adachi, JD ;
Ferko, N .
AMERICAN JOURNAL OF MEDICINE, 2002, 113 (03) :220-228
[29]   Percutaneous vertebroplasty: An update [J].
Peh, WCG ;
Gilula, LA .
SEMINARS IN ULTRASOUND CT AND MRI, 2005, 26 (02) :52-64
[30]   The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit - Finite-element analysis [J].
Polikeit, A ;
Nolte, LP ;
Ferguson, SJ .
SPINE, 2003, 28 (10) :991-996