Part 2: Dynamic mixed beam radiotherapy (DYMBER): Photon dynamic trajectories combined with modulated electron beams

被引:23
作者
Mueller, S. [1 ]
Manser, P. [1 ]
Volken, W. [1 ]
Frei, D. [1 ]
Kueng, R. [1 ]
Herrmann, E. [1 ]
Elicin, O. [1 ]
Aebersold, D. M. [1 ]
Stampanoni, M. F. M. [2 ,3 ]
Fix, M. K. [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Inselspital, Div Med Radiat Phys,Dept Radiat Oncol, CH-3010 Bern, Switzerland
[2] Swiss Fed Inst Technol, Inst Biomed Engn, CH-5232 Villigen, Switzerland
[3] PSI, CH-5232 Villigen, Switzerland
关键词
dynamic trajectory; mixed beam radiotherapy; Monte Carlo; treatment planning; DIRECT APERTURE OPTIMIZATION; PARTIAL BREAST IRRADIATION; CARLO DOSE CALCULATION; RADIATION-THERAPY; ARC THERAPY; NONCOPLANAR TRAJECTORIES; INTENSITY; IMRT; COMBINATION; COLLIMATOR;
D O I
10.1002/mp.13085
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe purpose of this study was to develop a treatment technique for dynamic mixed beam radiotherapy (DYMBER) utilizing increased degrees of freedom (DoF) of a conventional treatment unit including different particle types (photons and electrons), intensity and energy modulation and dynamic gantry, table, and collimator rotations. MethodsA treatment planning process has been developed to create DYMBER plans combining photon dynamic trajectories (DTs) and step and shoot electron apertures collimated with the photon multileaf collimator (pMLC). A gantry-table path is determined for the photon DTs with minimized overlap of the organs at risk (OARs) with the target. In addition, an associated dynamic collimator rotation is established with minimized area between the pMLC leaves and the target contour. pMLC sequences of photon DTs and electron pMLC apertures are then simultaneously optimized using direct aperture optimization (DAO). Subsequently, the final dose distribution of the electron pMLC apertures is calculated using the Swiss Monte Carlo Plan (SMCP). The pMLC sequences of the photon DTs are then re-optimized with a finer control point resolution and with the final electron dose distribution taken into account. Afterwards, the final photon dose distribution is calculated also using the SMCP and summed together with the one of the electrons. This process is applied for a brain and two head and neck cases. The resulting DYMBER dose distributions are compared to those of dynamic trajectory radiotherapy (DTRT) plans consisting only of photon DTs and clinically applied VMAT plans. Furthermore, the deliverability of the DYMBER plans is verified in terms of dosimetric accuracy, delivery time and collision avoidance. For this purpose, The DYMBER plans are delivered to Gafchromic EBT3 films placed in an anthropomorphic head phantom on a Varian TrueBeam linear accelerator. ResultsFor each case, the dose homogeneity in the target is similar or better for DYMBER compared to DTRT and VMAT. Averaged over all three cases, the mean dose to the parallel OARs is 16% and 28% lower, D-2% to the serial OARs is 17% and 37% lower and V-10% to normal tissue is 12% and 4% lower for the DYMBER plans compared to the DTRT and VMAT plans, respectively. The DYMBER plans are delivered without collision and with a 4-5min longer delivery time than the VMAT plans. The absolute dose measurements are compared to calculation by gamma analysis using 2% (global)/2mm criteria with passing rates of at least 99%. ConclusionsA treatment technique for DYMBER has been successfully developed and verified for its deliverability. The dosimetric superiority of DYMBER over DTRT and VMAT indicates utilizing increased DoF to be the key to improve brain and head and neck radiation treatments in future.
引用
收藏
页码:4213 / 4226
页数:14
相关论文
共 53 条
  • [21] Monte Carlo based treatment planning for modulated electron beam radiation therapy
    Lee, MC
    Deng, J
    Li, JS
    Jiang, SB
    Ma, CM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (08) : 2177 - 2199
  • [22] An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan
    Lewis, David
    Micke, Andre
    Yu, Xiang
    Chan, Maria F.
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 6339 - 6350
  • [23] Breast-conserving radiation therapy using combined electron and intensity-modulated radiotherapy technique
    Li, JG
    Williams, SS
    Goffinet, DR
    Boyer, AL
    Xing, L
    [J]. RADIOTHERAPY AND ONCOLOGY, 2000, 56 (01) : 65 - 71
  • [24] Validation of the Swiss Monte Carlo Plan for a static and dynamic 6 MV photon beam
    Magaddino, Vera
    Manser, Peter
    Frei, Daniel
    Volken, Werner
    Schmidhalter, Daniel
    Hirschi, Lukas
    Fix, Michael K.
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2011, 21 (02): : 124 - 134
  • [25] Dose calculation of dynamic trajectory radiotherapy using Monte Carlo
    Manser, Peter
    Frauchiger, Daniel
    Frei, Daniel
    Volken, Werner
    Terribilini, Dario
    Fix, Michael K.
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (01): : 31 - 38
  • [26] Modulated photon radiotherapy (XMRT): an algorithm for the simultaneous optimization of photon beamlet energy and intensity in external beam radiotherapy (EBRT) planning
    McGeachy, Philip
    Villarreal-Barajas, Jose Eduardo
    Zinchenko, Yuriy
    Khan, Rao
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (04) : 1476 - 1498
  • [27] Clinical implementation of combined modulated electron and photon beams with conventional MLC for accelerated partial breast irradiation
    Miguez, Carlos
    Jimenez-Ortega, Elisa
    Palma, Bianey A.
    Miras, Hector
    Ureba, Ana
    Arrans, Rafael
    Carrasco-Pena, Francisco
    Illescas-Vacas, Ana
    Leal, Antonio
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 124 (01) : 124 - 129
  • [28] Can photon IMRT be improved by combination with mixed electron and photon techniques?
    Mu, XK
    Olofsson, L
    Karlsson, M
    Sjögren, R
    Zackrisson, B
    [J]. ACTA ONCOLOGICA, 2004, 43 (08) : 727 - 735
  • [29] Electron beam collimation with a photon MLC for standard electron treatments
    Mueller, S.
    Fix, M. K.
    Henzen, D.
    Frei, D.
    Frauchiger, D.
    Loessl, K.
    Stampanoni, M. F. M.
    Manser, P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (02)
  • [30] Simultaneous optimization of photons and electrons for mixed beam radiotherapy
    Mueller, S.
    Fix, M. K.
    Joosten, A.
    Henzen, D.
    Frei, D.
    Volken, W.
    Kueng, R.
    Aebersold, D. M.
    Stampanoni, M. F. M.
    Manser, P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (14) : 5840 - 5860