Analysis of the coagulation of human blood cells on diamond surfaces by atomic force microscopy

被引:4
作者
Baranauskas, V [1 ]
Fontana, M [1 ]
Guo, ZJ [1 ]
Ceragioli, HJ [1 ]
Peterlevitz, AC [1 ]
机构
[1] Univ Estadual Campinas, Fac Engn Eletr & Computacao, BR-13083852 Campinas, SP, Brazil
关键词
D O I
10.1088/0957-4484/15/11/050
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Atomic force microscopy (AFM) was used to study the morphology and coagulation of human blood cells in contact with solid surfaces. Blood was extracted from the veins of healthy adult donors and the samples were used immediately after extraction, deposited either on borosilicate glass or diamond substrates. Some blood samples were anti-coagulated by adding heparin for single cell AFM imaging. No chemicals were used for attaching or immobilizing the cells. The diamond substrates were produced by chemical vapour deposition (CVD diamond) using a hot-filament CVD system fed with ethanol highly diluted in hydrogen. AFM imaging of isolated cells (anti-coagulated by heparin) was only possible on the glass substrates due to the lack of adherence of the cells to the diamond surface. The coagulation results suggest that blood clotting on diamond produces a less rough surface than blood clotting on glass.
引用
收藏
页码:1661 / 1664
页数:4
相关论文
共 21 条
[1]   LOW-PRESSURE, METASTABLE GROWTH OF DIAMOND AND DIAMONDLIKE PHASES [J].
ANGUS, JC ;
HAYMAN, CC .
SCIENCE, 1988, 241 (4868) :913-921
[2]   Blood compatibility and sp3/sp2 contents of diamond-like carbon (DLC) synthesized by plasma immersion ion implantation-deposition [J].
Chen, JY ;
Wang, LP ;
Fu, KY ;
Huang, N ;
Leng, Y ;
Leng, YX ;
Yang, P ;
Wang, J ;
Wan, GJ ;
Sun, H ;
Tian, XB ;
Chu, PK .
SURFACE & COATINGS TECHNOLOGY, 2002, 156 (1-3) :289-294
[3]   Evaluation of diamond-like carbon-coated orthopaedic implants [J].
Dowling, DP ;
Kola, PV ;
Donnelly, K ;
Kelly, TC ;
Brumitt, K ;
Lloyd, L ;
Eloy, R ;
Therin, M ;
Weill, N .
DIAMOND AND RELATED MATERIALS, 1997, 6 (2-4) :390-393
[4]  
HALL R, 1991, MED LAB HAEMATOLOGY, P109
[5]  
Jones MI, 2000, J BIOMED MATER RES, V52, P413, DOI 10.1002/1097-4636(200011)52:2<413::AID-JBM23>3.0.CO
[6]  
2-U
[7]   Force measurements on platelet surfaces with high spatial resolution under physiological conditions [J].
Lee, I ;
Marchant, RE .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2000, 19 (04) :357-365
[8]   Force measurements on the molecular interactions between ligand (RGD) and human platelet αIIb β3 receptor system [J].
Lee, I ;
Marchant, RE .
SURFACE SCIENCE, 2001, 491 (03) :433-443
[9]   Imaging erythrocytes under physiological conditions by atomic force microscopy [J].
Nowakowski, R ;
Luckham, P ;
Winlove, P .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2001, 1514 (02) :170-176
[10]   Quantification of red blood cells using atomic force microscopy [J].
O'Reilly, M ;
McDonnell, L ;
O'Mullane, J .
ULTRAMICROSCOPY, 2001, 86 (1-2) :107-112