In Situ Mg/Ca Measurements on Foraminifera: Comparison Between Laser Ablation Inductively Coupled Plasma Mass Spectrometry and Wavelength-Dispersive X-Ray Spectroscopy by Electron Probe Microanalyzer

被引:6
|
作者
Balestra, B. [1 ,2 ,3 ]
Rose, T. [4 ]
Fehrenbacher, J. [5 ]
Knobelspiesse, K. D. [6 ]
Huber, B. T. [2 ]
Gooding, T. [4 ]
Paytan, A. [3 ]
机构
[1] Amer Univ, Environm Sci Dept, Washington, DC 20016 USA
[2] Natl Museum Nat Hist, Dept Paleobiol, MRC 121, Washington, DC 20560 USA
[3] Univ Calif Santa Cruz, Inst Marine Sci, Santa Cruz, CA 95064 USA
[4] Natl Museum Nat Hist, Dept Mineral Sci, Washington, DC 20560 USA
[5] Oregon State Univ, Coll Earth Ocean & Atmospher Sci, Corvallis, OR 97331 USA
[6] NASA, Goddard Space Flight Ctr, Ocean Ecol Lab, Greenbelt, MD USA
关键词
EPMA; foraminifera; LA‐ ICP‐ MS; Mg; Ca; paired analysis; NEOGLOBOQUADRINA-DUTERTREI; PLANKTONIC-FORAMINIFERA; BENTHIC FORAMINIFERA; TRACE-ELEMENTS; VARIABILITY; CALCITE; TEMPERATURE; DELTA-O-18; DELTA-C-13; CHEMISTRY;
D O I
10.1029/2020GC009449
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
We present a comparison of two different techniques: Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) and wavelength-dispersive X-Ray Spectroscopy by electron probe microanalyzer (EPMA) for obtaining Mg/Ca ratios in individual foraminifera shells. The goal is to assess the use of EPMA as an alternative technique for Mg/Ca analyses of single foraminiferal calcite shells. Foraminifera obtained from sediments (benthic, Uvigerina spp.) and from plankton tows (planktonic, Orbulina universa) were analyzed. All specimens were prepared in epoxy mounts and exposed in cross-section such that multiple high-resolution analyses could be completed on the shells using both techniques. We examined our data using statistical methods designed for the assessment and comparison of measurement techniques. In the case of Uvigerina, the mean difference for ratios obtained using EPMA and LA-ICP-MS is very small (-0.046 mmol mol(-1)) and scale independent. The Limits of Agreement (LoA, the standard deviation of the bias plus the mean bias) is [-0.315, 0.223] mmol mol(-1). For samples with ratios lower than 13 mmol mol(-1), we found a mean EPMA-LA-ICP-MS bias of -2.44 mmol mol(-1) and a corresponding LoA of [-3.85, -1.04] mmol mol(-1). For ratios higher than 13 mmol mol(-1), there appears to be a scale dependent bias, meaning that the EPMA measured ratios become progressively larger than those of LA-ICP-MS as the Mg/Ca ratio increases, so the mean bias and LoA metrics are not meaningful. Results indicate that it is possible to use EPMA to collect Mg/Ca data, if the ratios are lower than similar to 13 mmol mol(-1).
引用
收藏
页码:1 / 10
页数:10
相关论文
共 16 条
  • [1] Elemental Bioimaging of Nanosilver-Coated Prostheses Using X-ray Fluorescence Spectroscopy and Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry
    Blaske, Franziska
    Reifschneider, Olga
    Gosheger, Georg
    Wehe, Christoph A.
    Sperling, Michael
    Karst, Uwe
    Hauschild, Gregor
    Hoell, Steffen
    ANALYTICAL CHEMISTRY, 2014, 86 (01) : 615 - 620
  • [2] Arsenic enrichment in hydrous peraluminous melts: Insights from femtosecond laser ablation-inductively coupled plasma-quadrupole mass spectrometry, and in situ X-ray absorption fine structure spectroscopy
    Borisova, Anastassia Y.
    Pokrovski, Gleb S.
    Pichavant, Michel
    Freydier, Remi
    Candaudap, Frederic
    AMERICAN MINERALOGIST, 2010, 95 (07) : 1095 - 1104
  • [3] In situ Mg isotope measurements of biogenic carbonates using laser ablation multi-collector inductively coupled plasma mass spectrometry: A new tool to understand biomineralisation
    Sadekov, Aleksey
    Lloyd, Nicholas S.
    Misra, Sambuddha
    D'Olivo, Juan Pablo
    McCulloch, Malcolm
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (23)
  • [4] A New Sample Fusion Technique for Quantitative Analysis of Major and Minor Elements in Sulfides with X-Ray Fluorescence Spectrometry and Laser Ablation Inductively Coupled Plasma Mass Spectrometry
    Xu Juan
    Yang Shou-ye
    Hu Zhao-chu
    Luo Tao
    Huang Xiang-tong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (11) : 3683 - 3688
  • [5] Elemental analysis of limestone by laser-induced breakdown spectroscopy, scanning electron microscopy coupled with energy dispersive x-ray spectroscopy and electron probe microanalysis
    Fahad, Muhammad
    Farooq, Zahid
    Abrar, Muhammad
    Shah, Khizar Hussain
    Iqbal, Tahir
    Saeed, Sundas
    LASER PHYSICS, 2018, 28 (12)
  • [6] Determination of toxic metals in leather by wavelength dispersive X-ray fluorescence (WDXRF) and inductively coupled plasma optical emission spectrometry (ICP OES) with emphasis on chromium
    Neiva, Ariane Maciel
    Speranca, Marco Aurelio
    Costa, Vinicius Camara
    Chagas Jacinto, Manuel Antonio
    Pereira-Filho, Edenir Rodrigues
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2018, 190 (10)
  • [7] Quantifying weathering rind formation rates using in situ measurements of U-series isotopes with laser ablation and inductively coupled plasma-mass spectrometry
    Ma, Lin
    Dosseto, Anthony
    Gaillardet, Jerome
    Sak, Peter B.
    Brantley, Susan
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2019, 247 : 1 - 26
  • [8] Trace element determination in soy sauce: A novel total reflection X-ray fluorescence procedure and comparison with inductively coupled plasma-mass spectrometry
    Monticelli, D.
    Cinosi, A.
    Siviero, G.
    Seralessandri, L.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 146 : 16 - 20
  • [9] Plasma Diagnostic by Optical Emission Spectroscopy on Dolomite and Cross-Validation Using Scanning Electron Microscopy Coupled with Energy Dispersive X-ray Spectroscopy and Electron Probe Micro-Analysis
    M. Fahad
    M. Abrar
    K. H. Shah
    A. Shahzad
    Plasma Physics Reports, 2020, 46 : 283 - 292
  • [10] Plasma Diagnostic by Optical Emission Spectroscopy on Dolomite and Cross-Validation Using Scanning Electron Microscopy Coupled with Energy Dispersive X-ray Spectroscopy and Electron Probe Micro-Analysis
    Fahad, M.
    Abrar, M.
    Shah, K. H.
    Shahzad, A.
    PLASMA PHYSICS REPORTS, 2020, 46 (03) : 283 - 292