Preventing Healthcare-Associated Legionellosis: Results after 3 Years of Continuous Disinfection of Hot Water with Monochloramine and an Effective Water Safety Plan

被引:19
作者
Coniglio, Maria Anna [1 ,2 ]
Ferrante, Margherita [2 ]
Yassin, Mohamed H. [3 ]
机构
[1] Univ Catania, Dept Med Surg Sci & Adv Technol GF Ingrassia, Legionella Reference Lab, Via Santa Sofia 87, I-95123 Catania, Italy
[2] AOU Policlin Vittorio Emanuele, Hyg Complex Operat Unit, Via S Sofia 87, I-95123 Catania, Italy
[3] UPMC, Infect Control Dept, Pittsburgh, PA 15213 USA
关键词
Legionella; Water Safety Plan; monochloramine; risk assessment; water distribution system; NOSOCOMIAL LEGIONNAIRES-DISEASE; CHLORINE DIOXIDE; PNEUMOPHILA; CONTAMINATION; ASPIRATION; INFECTION; BACTERIA; EFFICACY; BIOFILMS; SYSTEMS;
D O I
10.3390/ijerph15081594
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this study is to report the experience of the implementation and application of a 3-year Water Safety Plan (WSP) together with the secondary disinfection of water by monochloramine to control and prevent healthcare-associated legionellosis in an Italian hospital strongly colonized by Legionella. Risk assessment was carried out by the WSP team. The main critical control points focused on in developing the WSP for the control of Legionella was the water distribution system. A sampling plan for the detection of Legionella was implemented. A widespread contamination of the hot water distribution system by L. pneumophila sg5 was found. Results after 3 years of the continuous disinfection of hot water with monochloramine indicate the eradication of Legionella. The implementation and application of a WSP in a hospital, together with the disinfection of the water distribution system with monochloramine, can be effective in controlling the growth of Legionella and in preventing nosocomial legionellosis.
引用
收藏
页数:11
相关论文
共 45 条
[1]   Biofilms: The Stronghold of Legionella pneumophila [J].
Abdel-Nour, Mena ;
Duncan, Carla ;
Low, Donald E. ;
Guyard, Cyril .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2013, 14 (11) :21660-21675
[2]   FACTORS CONTRIBUTING TO THE CONTAMINATION OF HOSPITAL WATER DISTRIBUTION-SYSTEMS BY LEGIONELLAE [J].
ALARY, M ;
JOLY, JR .
JOURNAL OF INFECTIOUS DISEASES, 1992, 165 (03) :565-569
[3]  
Aldo B., 2017, INDOOR AIR QUALITY H, P63
[4]  
Allegheny County Health Department, 1997, APPR PREV CONTR LEG
[5]   Surveillance of Legionella species in hospital water systems: the significance of detection method for environmental surveillance data [J].
Asghari, Farzaneh Baghal ;
Nikaeen, Mahnaz ;
Hatamzadeh, Maryam ;
Hassanzadeh, Akbar .
JOURNAL OF WATER AND HEALTH, 2013, 11 (04) :713-719
[6]  
Bartram J., 2009, Water Safety Plan manual: Step-by-step risk management for drinking water suppliers
[7]  
Bartram Jamie, 2007, P1
[8]   Legionnaires' disease in Europe, 2011 to 2015 [J].
Beaute, J. .
EUROSURVEILLANCE, 2017, 22 (27) :7-14
[9]   Energy Conservation and the Promotion of Legionella pneumophila Growth: The Probable Role of Heat Exchangers in a Nosocomial Outbreak [J].
Bedard, Emilie ;
Levesque, Simon ;
Martin, Philippe ;
Pinsonneault, Linda ;
Paranjape, Kiran ;
Lalancette, Cindy ;
Dolce, Charles-Eric ;
Villion, Manuela ;
Valiquette, Louis ;
Faucher, Sebastien P. ;
Prevost, Michele .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2016, 37 (12) :1475-1480
[10]   NOSOCOMIAL LEGIONNAIRES-DISEASE - ASPIRATION AS A PRIMARY-MODE OF DISEASE ACQUISITION [J].
BLATT, SP ;
PARKINSON, MD ;
PACE, E ;
HOFFMAN, P ;
DOLAN, D ;
LAUDERDALE, P ;
ZAJAC, RA ;
MELCHER, GP .
AMERICAN JOURNAL OF MEDICINE, 1993, 95 (01) :16-22