Accuracy of 2D CT-Based Measurements of Rotational Alignment of the Femoral Component for Total Knee Arthroplasty

被引:5
作者
Park, Jun Young [1 ]
Kwon, Hyuck Min [2 ]
Cho, Byung Woo [3 ]
Lee, Woo-Suk [3 ]
Yang, Ick Hwan [1 ]
Park, Kwan Kyu [1 ]
机构
[1] Yonsei Univ, Severance Hosp, Dept Orthoped Surg, Coll Med, Seoul, South Korea
[2] Yonsei Univ, Yong Severance Hosp, Dept Orthoped Surg, Coll Med, Yongin, South Korea
[3] Yonsei Univ, Gangnam Severance Hosp, Dept Orthoped Surg, Coll Med, Seoul, South Korea
关键词
Knee; osteoarthritis; total knee arthroplasty; rotational alignment of the femoral component; 2D-CT; 3D reconstruction; SURGICAL EPICONDYLAR AXIS; DISTAL FEMUR; ORIENTATION; POSITION; GAP;
D O I
10.3349/ymj.2021.62.5.439
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We aimed to investigate the accuracy of two-dimensional computed tomography (2D-CT)-based methods for measuring rotational alignment of the femoral component during total knee arthroplasty in comparison to reference values for three-dimensional (3D) reconstruction. Materials and Methods: We selected the "most protruding transepicondylar axis section," "most protruding posterior condylar line section," and "distal femoral cut section" on 2D-CT images for 100 knees. We investigated posterior condylar angle (PCA) and condylar twist angle (CTA) values using three different methods on 2D-CT and compared to these values to those obtained using a 3D model. Results: The mean PCA and CTA values were 2.8 degrees and 7.0 degrees on the 3D model and 2.0 degrees to 2.1 degrees and 5.9 degrees to 6.0 degrees on 2D-CT, respectively. Errors in PCA and CTA measurement included internal rotation of 0.8 degrees and 1.1 degrees with the 1-plane and 2-plane methods and 0.9 degrees and 1.0 degrees with the assumed resection method, respectively. Conclusion: Mean errors in PCA and CTA values measured using three different methods on 2D-CT were not significantly different. However, PCA and CTA values measured on 2D-CT were approximately 1 degrees smaller than their 3D values. Thus, we suggest that adding 1 degrees to the mean PCA and CTA values obtained from a single plane of 2D-CT would provide values similar to those obtained from 3D reconstruction.
引用
收藏
页码:439 / 445
页数:7
相关论文
共 25 条
[1]  
Akagi M, 2001, CLIN ORTHOP RELAT R, P147
[2]   The functional flexion-extension axis of the knee corresponds to the surgical epicondylar axis - In vivo analysis using a biplanar image-matching technique [J].
Asano, T ;
Akagi, M ;
Nakamura, T .
JOURNAL OF ARTHROPLASTY, 2005, 20 (08) :1060-1067
[3]  
BERGER RA, 1993, CLIN ORTHOP RELAT R, P40
[4]   Malrotation causing patellofemoral complications after total knee arthroplasty [J].
Berger, RA ;
Crossett, LS ;
Jacobs, JJ ;
Rubash, HE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (356) :144-153
[5]   Soft Tissue Releases Affect the Femoral Component Rotation Necessary to Create a Balanced Flexion Gap During Total Knee Arthroplasty [J].
Christensen, Christian P. ;
Stewart, Allison H. ;
Jacobs, Cale A. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (09) :1528-1532
[6]   Gap Balancing versus Measured Resection Technique for Total Knee Arthroplasty [J].
Dennis, Douglas A. ;
Komistek, Richard D. ;
Kim, Raymond H. ;
Sharma, Adrija .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) :102-107
[7]   Statistical power analyses using G*Power 3.1: Tests for correlation and regression analyses [J].
Faul, Franz ;
Erdfelder, Edgar ;
Buchner, Axel ;
Lang, Albert-Georg .
BEHAVIOR RESEARCH METHODS, 2009, 41 (04) :1149-1160
[8]   Patient Dissatisfaction Following Total Knee Arthroplasty: A Systematic Review of the Literature [J].
Gunaratne, Rajitha ;
Pratt, Dylan N. ;
Banda, Joseph ;
Fick, Daniel P. ;
Khan, Riaz J. K. ;
Robertson, Brett W. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (12) :3854-3860
[9]   A Novel Approach for Determining Three-Dimensional Acetabular Orientation: Results from Two Hundred Subjects [J].
Higgins, Sean W. ;
Spratley, E. Meade ;
Boe, Richard A. ;
Hayes, Curtis W. ;
Jiranek, William A. ;
Wayne, Jennifer S. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (21) :1776-1784
[10]   The position and orientation of total knee replacement components A COMPARISON OF CONVENTIONAL RADIOGRAPHS, TRANSVERSE 2D-CT SLICES AND 3D-CT RECONSTRUCTION [J].
Hirschmann, M. T. ;
Konala, P. ;
Amsler, F. ;
Iranpour, F. ;
Friederich, N. F. ;
Cobb, J. P. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (05) :629-633