Biological infrared microspectroscopy at the National Synchrotron Light Source

被引:0
作者
Miller, LM [1 ]
Carr, GL [1 ]
Williams, GP [1 ]
Sullivan, M [1 ]
Chance, MR [1 ]
机构
[1] Brookhaven Natl Lab, Natl Synchrotron Light Source, Upton, NY 11973 USA
来源
SYNCHROTRON RADIATION INSTRUMENTATION | 2000年 / 521卷
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Beamline U2B at the National Synchrotron Light Source has been designed and built as an infrared beamline dedicated to the study of biomedical problems. In 1997, the horizontal and vertical acceptances of Beamline U2B were increased in order to increase the overall flux of the beamline. A wedged, CVD diamond window separates the UHV vacuum of the VUV ring from the rough vacuum of the beamline. The endstation consists of a Nicolet Magna 860 step-scan FTIR and a NicPlan infrared microscope. The spectrometer is equipped with beamsplitter/detector combinations that permit data collection in the mid- and far-infrared regions. We have also made provisions for mounting an external detector (e.g. bolometer) for far infrared microspectroscopy. Thus far, Beamline U2B has been used to (1) perform chemical imaging of bone tissue and brain cells to address issues related to bone disease and epilepsy, respectively, and (2) examine time-resolved protein structure in the sub-millisecond folding of cytochrome c.
引用
收藏
页码:47 / 50
页数:4
相关论文
共 11 条
[1]   EXAMINATION OF THE SECONDARY STRUCTURE OF PROTEINS BY DECONVOLVED FTIR SPECTRA [J].
BYLER, DM ;
SUSI, H .
BIOPOLYMERS, 1986, 25 (03) :469-487
[2]  
Carr GL, 1997, P SOC PHOTO-OPT INS, V3153, P51, DOI 10.1117/12.290262
[3]   High-resolution microspectroscopy and sub-nanosecond time-resolved spectroscopy with the synchrotron infrared source [J].
Carr, GL .
VIBRATIONAL SPECTROSCOPY, 1999, 19 (01) :53-60
[4]  
CARR GL, IN PRESS SPIE C P
[5]  
Jamin N, 1998, CELL MOL BIOL, V44, P9
[6]   Highly resolved chemical imaging of living cells by using synchrotron infrared microspectrometry [J].
Jamin, N ;
Dumas, P ;
Moncuit, J ;
Fridman, WH ;
Teillaud, JL ;
Carr, GL ;
Williams, GP .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (09) :4837-4840
[7]  
Miller LM, 1998, CELL MOL BIOL, V44, P117
[8]  
MILLER LM, 1999, SYNCHROTRON RAD NEWS, V12, P21
[9]  
MILLER LM, IN PRESS SPIE C P
[10]   FOURIER-TRANSFORM INFRARED MICROSCOPIC ANALYSIS WITH SYNCHROTRON-RADIATION - THE MICROSCOPE OPTICS AND SYSTEM PERFORMANCE [J].
REFFNER, JA ;
MARTOGLIO, PA ;
WILLIAMS, GP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1298-1302