Investigation of fluid cell resonances in intermittent contact mode atomic force microscopy

被引:17
作者
Kokavecz, J.
Mechler, A.
机构
[1] Univ Szeged, Inst Engn & Mat Sci, H-6701 Szeged, Hungary
[2] Monash Univ, Sch Chem, Clayton, Vic 3800, Australia
基金
匈牙利科学研究基金会;
关键词
CANTILEVERS; LIQUID; DRIVEN;
D O I
10.1063/1.2753104
中图分类号
O59 [应用物理学];
学科分类号
摘要
In fluid, the probe resonance curve of the atomic force microscope contains several apparent resonance peaks whose origin is not well understood. In this work, the authors focus on identifying the cause of these peaks and finding the optimal imaging conditions for acoustic intermittent contact mode in fluid environment. The authors demonstrate that the peaks are also present in the spectrum of the fluid movement and in that of the shaker piezo. These peaks may or may not coincide with the natural resonance of a probe in liquid, thus it is possible to drive the probes off-resonance. Numerical calculations show the feasibility of off-resonance imaging, but predict much higher imaging force. (C) 2007 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 17 条
[1]   Analysis of the interaction mechanisms in dynamic mode SFM by means of experimental data and computer simulation [J].
Anczykowski, B ;
Cleveland, JP ;
Kruger, D ;
Elings, V ;
Fuchs, H .
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1998, 66 (Suppl 1) :S885-S889
[2]   Hydrodynamic loading of microcantilevers vibrating in viscous fluids [J].
Basak, Sudipta ;
Raman, Arvind ;
Garimella, Suresh V. .
JOURNAL OF APPLIED PHYSICS, 2006, 99 (11)
[3]   ATOMIC FORCE MICROSCOPE [J].
BINNIG, G ;
QUATE, CF ;
GERBER, C .
PHYSICAL REVIEW LETTERS, 1986, 56 (09) :930-933
[4]   How does a tip tap? [J].
Burnham, NA ;
Behrend, OP ;
Oulevey, F ;
Gremaud, G ;
Gallo, PJ ;
Gourdon, D ;
Dupas, E ;
Kulik, AJ ;
Pollock, HM ;
Briggs, GAD .
NANOTECHNOLOGY, 1997, 8 (02) :67-75
[5]   SCAN SPEED LIMIT IN ATOMIC FORCE MICROSCOPY [J].
BUTT, HJ ;
SIEDLE, P ;
SEIFERT, K ;
FENDLER, K ;
SEEGER, T ;
BAMBERG, E ;
WEISENHORN, AL ;
GOLDIE, K ;
ENGEL, A .
JOURNAL OF MICROSCOPY-OXFORD, 1993, 169 :75-84
[6]   Increasing the Q factor in the constant-excitation mode of frequency-modulation atomic force microscopy in liquid [J].
Ebeling, D. ;
Hoelscher, H. ;
Anczykowski, B. .
APPLIED PHYSICS LETTERS, 2006, 89 (20)
[7]   Lorentz-force-induced excitation of cantilevers for oscillation-mode scanning probe microscopy [J].
Enders, O ;
Korte, F ;
Kolb, HA .
SURFACE AND INTERFACE ANALYSIS, 2004, 36 (02) :119-123
[8]   A magnetically driven oscillating probe microscope for operation in liquids [J].
Han, WH ;
Lindsay, SM ;
Jing, TW .
APPLIED PHYSICS LETTERS, 1996, 69 (26) :4111-4113
[9]   Q-controlled amplitude modulation atomic force microscopy in liquids:: An analysis [J].
Holscher, H. ;
Schwarz, U. D. .
APPLIED PHYSICS LETTERS, 2006, 89 (07)
[10]   ANALYSIS OF THE RESONANCE CHARACTERISTICS OF A CANTILEVER VIBRATED PHOTOTHERMALLY IN A LIQUID [J].
INABA, S ;
AKAISHI, K ;
MORI, T ;
HANE, K .
JOURNAL OF APPLIED PHYSICS, 1993, 73 (06) :2654-2658