Three-way multivariate calibration procedures applied to high-performance liquid chromatography coupled with fast-scanning fluorescence spectrometry detection.: Determination of polycyclic aromatic hydrocarbons in water samples

被引:55
作者
Beltrán, JL [1 ]
Guiteras, J [1 ]
Ferrer, R [1 ]
机构
[1] Univ Barcelona, Dept Quim Analit, E-08028 Barcelona, Spain
关键词
D O I
10.1021/ac970939b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three-way partial least-squares and n factor parallel factor analysis have been compared for the analysis of polycyclic aromatic hydrocarbons in water samples. Data were obtained with a chromatographic system set to record short-time chromatograms containing several unresolved peaks. The detection system consisted of a fast-scanning fluorescence spectra detector, which allows one to obtain three-dimensional data, where retention time, emission wavelengths, and fluorescence intensity are represented. The combined use of a multivariate calibration method and the three-dimensional data obtained from the HPLC-FSFS system allows resolution of closely eluting compounds, thus making a complete separation unnecessary. The procedure has been applied to tap water samples (spiked at 0.10 and 0.20 mu g L-1 levels) with good results, similar to those obtained with a HPLC system with a conventional fluorescence detector.
引用
收藏
页码:1949 / 1955
页数:7
相关论文
共 34 条
[1]  
Bjorseth A., 1983, HDB POLYCYCLIC AROMA
[2]   Single measurement excitation/emission matrix spectrofluorometer for determination of hydrocarbons in ocean water .2. Calibration and quantitation of naphthalene and styrene [J].
Booksh, KS ;
Muroski, AR ;
Myrick, ML .
ANALYTICAL CHEMISTRY, 1996, 68 (20) :3539-3544
[3]  
BRERETON RG, 1995, CHEMOMETR INTELL LAB, V27, P73
[4]  
Bro R, 1996, J CHEMOMETR, V10, P47, DOI 10.1002/(SICI)1099-128X(199601)10:1<47::AID-CEM400>3.3.CO
[5]  
2-3
[6]   DETERMINATION OF POLYCYCLIC AROMATIC-HYDROCARBONS IN SURFACE-WATER BY COLUMN LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION, USING ONLINE MICELLE-MEDIATED SAMPLE PREPARATION [J].
BROUWER, ER ;
HERMANS, ANJ ;
LINGEMAN, H ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1994, 669 (1-2) :45-57
[7]   DETERMINATION OF POLYCYCLIC AROMATIC-HYDROCARBONS IN SOIL SAMPLES BY MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY WITH PHOTODIODE-ARRAY DETECTION [J].
BRUGGEMANN, O ;
FREITAG, R .
JOURNAL OF CHROMATOGRAPHY A, 1995, 717 (1-2) :309-324
[8]   FLUORESCENCE DETECTION IN LIQUID-CHROMATOGRAPHY WITH AN INTENSIFIED DIODE-ARRAY DETECTOR [J].
CECIL, TL ;
RUTAN, SC .
JOURNAL OF CHROMATOGRAPHY, 1991, 556 (1-2) :495-503
[9]   SIMULTANEOUS MEASUREMENTS OF CAPILLARY ELECTROPHORESIS FLUORESCENCE PEAKS AND THEIR CORRESPONDING SPECTRA [J].
DALHOEVEN, GAM ;
JOSHI, NV ;
RODRIGUEZ, N ;
HERNANDEZ, L .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (18-19) :3729-3749
[10]  
DORSEY JG, 1994, ANAL CHEM, V66, pR500