Optimal distance between jet fans used to extinguish metropolitan tunnel fires: A case study using fire dynamic simulator modeling

被引:23
作者
Weng, Miaocheng [1 ,2 ,3 ,4 ]
Obadi, Imad [1 ]
Wang, Fei [1 ]
Liu, Fang [1 ,2 ,3 ,4 ]
Liao, Chunhui [1 ,2 ,3 ,4 ]
机构
[1] Chongqing Univ, Fac Urban Construct & Environm Engn, Chongqing 400045, Peoples R China
[2] Minist Educ, Key Lab Three Gorges Reservoir Reg Ecoenvironm, Chongqing 400045, Peoples R China
[3] Natl Ctr Int Res Low Carbon & Green Bldg, Chongqing 400045, Peoples R China
[4] Minist Educ, Joint Int Res Lab Green Bldg & Built Environm, Chongqing 400045, Peoples R China
基金
中国国家自然科学基金;
关键词
Extra-long tunnel; FDS; Jet fan; Temperature; Tunnel fire; Velocity; LONGITUDINAL VENTILATION; ROAD TUNNEL; SMOKE FLOW; CRITICAL VELOCITY; NATURAL VENTILATION; TEMPERATURE; PERFORMANCE; SAFETY; EXTRACTION; RAILWAY;
D O I
10.1016/j.tust.2019.103116
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Several disastrous tunnel fires have occurred in recent decades; safe evacuation, minimization of damage, and reliable ventilation have received a great deal of attention. Here, we use the Fire Dynamic Simulator (FDS) software to optimize jet fan spacing in an extra-long tunnel: the Zhong Liangshan tunnel of Metropolitan Line 1 in Chongqing, China. The model tunnels were 500, 550, and 600 m in length, with cross-sectional areas of 30.72 m(2); the jet fans were elevated 5.60 m from the floor at different spacings (100, 150, and 200 m). A 5-MW fire burned at 200, 175, and 150 m from the tunnel entrance. We simulated five scenarios using FDS software and compared airflow velocity and temperature curves. We also briefly investigated the effect of the length of an extra-long tunnel. The numerical results revealed that the air temperature always remained well below the 60 degrees C that the human body can withstand during evacuation necessitated by a fire; the air velocity remained nearly constant. We built a 1:15-scale model to validate the simulation; the simulation and experimental curves were in good agreement.
引用
收藏
页数:12
相关论文
共 52 条
[1]   Non-destructive testing of fired tunnel walls:: the Mont-Blanc Tunnel case study [J].
Abraham, O ;
Dérobert, X .
NDT & E INTERNATIONAL, 2003, 36 (06) :411-418
[2]  
[Anonymous], COMP METH ENG SCI P
[3]  
[Anonymous], DIRECT LARGE EDDY SI
[4]  
[Anonymous], VALIDATION AIR VENTI
[5]  
[Anonymous], 3 INT C SAF ROAD RAI
[6]  
[Anonymous], P BHR GROUP 12 INT S
[7]  
[Anonymous], TRANSP RES BOARD
[8]  
[Anonymous], 2005, TUNNEL FIRE INVESTIG
[9]  
Bailey J.L., 2002, J. Fire Prot. Eng., V12, P139, DOI DOI 10.1177/10423910260620473
[10]   Fire safety in tunnels [J].
Beard, Alan N. .